It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
The research involves an experimental investigation into the performance of a flow assisting air heat exchanger under varying angular orientation and uniform external heat fluxes without and with spring turbulators. The investigation was performed for Reynolds numbers ranging from 511 to 9676 and inclination angle 15° and 30°. Three heat fluxes (2, 3, and 4 kW/m2) were applied to the test section to investigate the effect of external surface heating on the range of transition flow regime and thermohydraulic performance. Transition from laminar to turbulent flow for plain channel at different heat fluxes and inclinations occurs within specific Reynolds number ranges: 2436–4446 for 15° inclination at 4 kW/m2, 2574–4289 at 3 kW/m2, and 2850–4152 at 2 kW/m2; for 30° inclination, the ranges are 2518–4151, 2712–4361, and 2992–4346 at the respective heat fluxes. When it comes to the effect of inclination on Nusselt number, the transition occurs sooner at lower angles, but is delayed as the angle increases. Additionally, the Nusselt number decreases as the angle of inclination increases. When comparing the Nusselt numbers of plain tubes to those with spring turbulators, the latter shows a significantly greater enhancement. In laminar flow, a maximum 100% deviation exists between highest and lowest friction factors, decreasing to 75% with increasing Reynolds number; all insert configurations exhibit highest friction factor at 15° due to stronger buoyancy forces.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 BITS Pilani, Pilani Campus, Department of Mechanical Engineering, Pilani, India (GRID:grid.418391.6) (ISNI:0000 0001 1015 3164); SRMIST, Center of Excellence for Electronics Cooling and Computational Fluid Dynamics Simulation Lab, Chengalpattu District, India (GRID:grid.418391.6)
2 BITS Pilani, Pilani Campus, Department of Mechanical Engineering, Pilani, India (GRID:grid.418391.6) (ISNI:0000 0001 1015 3164)