Full text

Turn on search term navigation

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: Obstructive sleep apnea is a sleep disorder that is linked to many health complications and can even be lethal in its severe form. Overnight polysomnography is the gold standard for diagnosing apnea, which is expensive, time-consuming, and requires manual analysis by a sleep expert. Artificial intelligence (AI)-embedded wearable device as a portable and less intrusive monitoring system is a highly desired alternative to polysomnography. However, AI models often require substantial storage capacity and computational power for edge inference which makes it a challenging task to implement the models in hardware with memory and power constraints. Methods: This study demonstrates the implementation of depth-wise separable convolution (DSC) as a resource-efficient alternative to spatial convolution (SC) for real-time detection of apneic activity. Single lead electrocardiogram (ECG) and oxygen saturation (SpO2) signals were acquired from the PhysioNet databank. Using each type of convolution, three different models were developed using ECG, SpO2, and model fusion. For both types of convolutions, the fusion models outperformed the models built on individual signals across all the performance metrics. Results: Although the SC-based fusion model performed the best, the DSC-based fusion model was 9.4, 1.85, and 11.3 times more energy efficient than SC-based ECG, SpO2, and fusion models, respectively. Furthermore, the accuracy, precision, and specificity yielded by the DSC-based fusion model were comparable to those of the SC-based individual models (~95%, ~94%, and ~94%, respectively). Conclusions: DSC is commonly used in mobile vision tasks, but its potential in clinical applications for 1-D signals remains unexplored. While SC-based models outperform DSC in accuracy, the DSC-based model offers a more energy-efficient solution with acceptable performance, making it suitable for AI-embedded apnea detection systems.

Details

Title
Lightweight and Low-Parametric Network for Hardware Inference of Obstructive Sleep Apnea
Author
Tanmoy, Paul 1 ; Omiya Hassan 2   VIAFID ORCID Logo  ; McCrae, Christina S 3   VIAFID ORCID Logo  ; Islam, Syed Kamrul 2   VIAFID ORCID Logo  ; Abu Saleh Mohammad Mosa 1   VIAFID ORCID Logo 

 Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA; [email protected] (T.P.); [email protected] (O.H.); [email protected] (S.K.I.); Department of Biomedical Informatics, Biostatistics, and Medical Epidemiology, School of Medicine, University of Missouri, Columbia, MO 65211, USA 
 Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA; [email protected] (T.P.); [email protected] (O.H.); [email protected] (S.K.I.) 
 School of Nursing, University of South Florida, Tampa, FL 33620, USA; [email protected] 
First page
2505
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
20754418
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3132921413
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.