1 Introduction
Black carbon (BC) exerts notable warming effects due to its strong light absorption (Andreae, 2001; Bond et al., 2013; Gustafsson and Ramanathan, 2016; Horvath and Trier, 1993; Jacobson, 2001; McConnell et al., 2007). BC absorption is largely influenced by its “mixing state” (Bond et al., 2013; Cappa et al., 2012; Fierce et al., 2020; Liu et al., 2017, 2015; Riemer et al., 2019), a term that describes to what extent the BC component is mixed with or coated by other aerosol components (Bondy et al., 2018; Winkler, 1973). After being emitted, fresh BC can mix with other non-absorbing aerosol components, enhancing its light absorption due to the “lensing effect” (Bond and Bergstrom, 2006; Jacobson, 2001; Peng et al., 2016; Redemann et al., 2001). This leads to larger mass absorption cross-sections (MACs) compared to freshly emitted or bare BC. Previous laboratory studies have shown that the light absorption enhancement () of BC aerosols can vary from 1.05 to 3.50 under controlled experimental conditions, depending on BC mixing states (Jacobson, 2001; Ramanathan and Carmichael, 2008; Riemer et al., 2019; Schnaiter et al., 2005; Shiraiwa et al., 2010). Therefore, accurately characterizing the BC mixing state is crucial for the precise assessment of the climate impact of BC aerosols.
The mixing state of BC aerosols in the real atmosphere is dynamically varying due to continuous changes caused by various processes such as the emission of particles, condensation of inorganic and organic substances on the BC aerosol, coagulation, and deposition (Moteki et al., 2007; Shiraiwa et al., 2007). Some studies have attempted to represent the BC mixing state using simplified aerosol representations, such as assuming a priori internal or external mixtures of BC aerosols (He et al., 2015; Lesins et al., 2002). However, these approaches disregard the continuous changes of the BC mixing state. Other studies have used a fixed rate to describe the aging of BC aerosols from fresh BC to aged BC (Qi et al., 2017a, b), but this approach also fails to fully capture the continuous changes.
The particle-resolved Monte Carlo and Model for Simulating Aerosol Interactions and Chemistry (PartMC-MOSAIC) offers a more detailed simulation of the continuous changes in the BC mixing state (Riemer et al., 2009; Zaveri et al., 2008). This model possesses the capability to track the state of individual aerosol particles during the simulation process (Ching et al., 2018; Hughes et al., 2018; Riemer et al., 2009, 2019; Shou et al., 2019; Zaveri et al., 2010; Zheng et al., 2021). However, the direct application of particle-resolved models within large-scale chemistry transport models or Earth system models is impeded due to the high computational cost required for their high-precision particle simulation. To overcome this challenge, the approximation of the exponential linear distribution of coating thickness (CT) under a BC steady-state mixing state has been recently proposed. The study of Wang et al. (2023) suggests that particles emitted into the atmosphere undergo continuous growth and deposition processes, leading to the formation of a steady state, where the CT distribution of BC aerosols across different sizes of BC cores does not change over time. This approach has the promise to simplify the representation of the continuously changing BC mixing state in models. However, the theory of BC steady-state mixing state still requires numerical validation, and key scientific questions remain unresolved: (1) do the properties of BC aerosols demonstrate a tendency towards a steady state, and how can the steady-state characteristic time be quantified? (2) Under the steady-state assumption, can the optical properties of BC be evaluated efficiently and accurately? (3) How can the steady-state theory be applied in models, and under what specific conditions is it applicable? Additionally, the study of Fierce et al. (2016) has noted that the composition of BC aerosols is non-uniform across the distributions of BC cores, which seems inconsistent with the conclusion of exponential linear CT distribution in the steady-state theory. This apparent discrepancy has not yet been fully explained.
In this study, we determine whether BC aerosols' mixing state reaches a steady state while the population is exposed to continuous emission, growth, and deposition processes using the PartMC-MOSAIC model. The set of baseline case was based on field observations and model simulations (Ding et al., 2016; Riemer et al., 2009; Wang et al., 2017). We also examine the characteristic time of BC aerosols reaching a steady-state mixing state, the CT distribution, and the optical properties of BC aerosols under the steady state. The steady-state CT distribution of BC aerosols will be compared with the results obtained from field observation in Nanjing, China, to verify the realism of the baseline case. Moreover, we explain the apparent discrepancy between the non-uniform composition of BC aerosols found in previous studies and the exponential linear CT distribution confirmed in this study. Our study aims to provide a simplified and reasonably precise approach for the characterization of BC mixing state and evaluation of the light absorption enhancement in global models or chemical transport models.
2 Materials and methods
2.1 Description of observational data
Observational data of BC mixing states were collected from the Station for Observing Regional Processes of the Earth system (SORPES; 32°07′14′′ N, 118°57′10′′ E; 40 m a.s.l.) in Nanjing (Ding et al., 2016). Observational data from April 2020 were used in this study. The physical properties of BC aerosols were measured by single particle soot photometers (SP2, Droplet Measurement Technologies, USA). The working principle of the SP2 has been thoroughly described in earlier studies (Gao et al., 2007; Schwarz et al., 2006). The BC mass can be determined based on its proportional relationship with the peak intensity of the emitted light, and the BC mass equivalent diameter can be calculated. The scattering cross-section of BC particles is calculated using the leading-edge-only fit method developed by Gao et al. (2007). Temperature and atmospheric pressure were continuously measured by the Nanjing automatic weather station throughout the year 2020, with a time resolution of 30 min.
2.2 The particle-resolved model PartMC-MOSAIC
In this study, we utilized the PartMC-MOSAIC model to verify the process of BC aerosols reaching a steady-state mixing state. This model simulates the time evolution of the BC mixing state by tracking the composition of individual computational particles during atmospheric processes (Ching et al., 2018; Shou et al., 2019; Zaveri et al., 2008, 2010). Particle size information can be calculated from the composition of individual particles assuming spherical particles. Subsequently, the BC mixing state can be derived from the aforementioned details. We utilized PartMC-MOSAIC simulations to obtain a precise representation of the BC mixing state, forming the numerical basis for our steady-state analysis.
To investigate the evolution of the mixing state of BC aerosols in typical regions under continuous emissions and diverse atmospheric processes, we constructed a scenario that simulates an urban area using approximately 10 000 computational particles (the precise values change throughout the simulation) for 10 d. The temperature and atmospheric pressure in the scenario were set to constant values consistent with the monthly average values measured by the Nanjing automatic weather station during the period from 1 to 30 April 2020. In this study, the initial gas concentration and emission rate were established in accordance with the parameters set by Riemer et al. (2009). To reflect the typical composition of aerosols in China, the setup for the baseline case was subsequently adjusted based on the observations reported by Wang et al. (2017) and X. Zhang et al. (2024), as detailed in Table S1 in the Supplement. Since time-varying emissions do not affect the average behavior (refer to the discussion in the Supplement of Wang et al., 2023), for simplicity, the emissions of gases and particles have been set to constant values in the baseline case. We prescribe three different types of carbonaceous aerosol emissions throughout the simulation representing a mix of urban sources (Cao et al., 2006; Schwarz et al., 2008a), namely pure BC particles (24.6 % of the emissions by number), pure organic carbon (OC) particles (72.7 % of the emissions by number), and mixed particles (2.7 % of the emissions by number), assuming that their size distributions are log-normal. The pure BC and the mixed particles were assigned a BC core size distribution with 89 nm geometric mean diameter and a geometric standard deviation of 1.6 following the results obtained by the SP2 instrument in Nanjing from 1 to 30 April 2020 (Fig. S1 in the Supplement). The mass proportions of OC and BC are set to 31.7 % and 68.3 %, to ensure that particles with the BC core of 89 nm have the OC coating layer with a thickness of 20 nm (Schwarz et al., 2008a). The distribution of pure OC particle emission was represented by a geometric mean diameter of 110 nm and a geometric standard deviation of 1.7 (Fierce et al., 2016). The above settings ensure a mass ratio of between component BC and component OC (Cao et al., 2006) while also maintaining a number concentration ratio of approximately between pure BC particles and mixed particles (Schwarz et al., 2008a). The detailed setup of the baseline case is provided in Table S1.
After emission, the combustion particles underwent further coating through gas–particle partitioning and coagulation due to Browning motion, and particles were removed by deposition, resulting in a complex mixing state. To mimic actual atmospheric conditions, we set a fixed emission rate of BC particles and maintained atmospheric processes throughout the simulation. The deposition rate of particles was set at a fixed rate, and gas–particle partitioning was determined by the concentration of particles and gaseous species. While the simulation includes the full simulation of gas-phase chemistry, gas–particle partitioning, aerosol thermodynamics, and the properties of BC aerosols undergoing continuous changes (Riemer et al., 2019), our study only focused on the mixture of aerosol species and the CT distribution of BC aerosols. The simulated aerosol component fractions are consistent with those in the ambient environment of China, provided in Table S2. To illustrate the generality of the steady state, we have created 12 additional cases by varying parameters such as temperature, emissions from natural biomass burning BC and industrial BC (Bond et al., 2013; Lee, 1983; Moteki, 2023), the growth rate within the simulated area (by increasing or decreasing particle and gas emissions by a factor of 5), and diurnal gas emissions condition. Detailed descriptions of these cases are provided in Sect. S1.2 in the Supplement.
2.3 Mixing state metrics
By storing the composition of individual computational particles (i.e., the full aerosol state), PartMC-MOSAIC output contains the full information on BC mixing state. However the output is exceedingly complex, requiring about () of values to describe the aerosol state at a specific time, thereby posing challenges in comparing BC mixing states at different times (Riemer et al., 2019). To overcome this, we conducted dimensionality reduction on the mixing state data by projecting the full aerosol state onto one or multiple values and assessing the mixing state through metrics. This study employed the metrics (Riemer and West, 2013) and (Wang et al., 2023) to quantify the BC mixing state and track the process of BC reaching a steady-state mixing state throughout the simulation. The metric represents the aerosol mixing state based on diversity metrics, whereas the metric originates from the particle size distribution. The characterization of the BC mixing state using the two metrics, and , allows us to assess the steady-state phenomenon of the mixing state by examining both the aerosol composition and the distribution of the BC coating layer.
The diversity metric utilized in this study was proposed by Riemer and West (2013) to characterize the aerosol mixing state of a particle population. This metric is determined by the mass fractions of each species in each particle, ranging from 0 % to 100 % to represent fully external to internal mixtures. In this paper, we focus on the mixing of BC and other components. So, species are separated into two surrogate species, BC and non-BC, in the calculation of metric (Zhao et al., 2021). PartMC-MOSAIC output can provide the mass of species in particle represented as , for ranging from 1 to and taking values of 1 or 2, where 1 denotes BC and 2 denotes non-BC. From this basic description of the aerosol particles, we can construct all associated quantities, as described by Riemer and West (2013) and listed in Table 1.
Table 1
Metrics of species masses in particles, adapted from Riemer and West (2013).
Quantity | Meaning |
---|---|
Mass of species in particle | |
Total mass of particle | |
Total mass of species in the population | |
Total mass of population | |
Mass fraction of species in particle | |
Mass fraction of particle in the population | |
Mass fraction of species in the population |
By utilizing the distribution of different aerosol components both within individual aerosol particles and across the entire population, we can now calculate the mixing entropies, species diversities, and the mixing state metrics, as presented in Table 2. The entropy or diversity of an individual particle quantifies the number of effective species within a particle. This metric ranges from a minimum value, where and , indicating a particle comprised solely of a single component (either BC or non-BC), to a maximum value, where and , signifying a particle composed of equal mass proportions of BC and non-BC components. Alpha diversity () quantifies the average effective number of species per particle within a population, with values ranging from 1, indicating that each particle is composed of a single species (though not necessarily the same species across particles), to a maximum value of 2 when all particles exhibit identical mass fractions. Conversely, gamma diversity () assesses the effective number of species within the entire population, with values ranging from 1, signifying a population consisting of a single species, to a maximum value when there are equal bulk mass fractions of all species present. The two population diversity metrics, (per-particle) and (bulk), can be integrated to yield a single mixing state metric , which quantifies the homogeneity or heterogeneity of the population. This metric ranges from , indicating a fully externally mixed population where all particles are pure, to , signifying a fully internally mixed population where all particles exhibit identical mass fractions. Therefore, the metric in this paper can describe the mixing of BC and non-BC components. The variation of metric is instrumental in more effectively tracking the process by which the BC core is coated with other non-BC components.
Table 2The computation of diversity metrics, adapted from Riemer and West (2013).
Quantity | Name | Meaning |
---|---|---|
Mixing entropy of particle | Shannon entropy of species distribution within particle | |
Average particle mixing entropy | Shannon entropy of species distribution within particle | |
Population bulk mixing entropy | Shannon entropy of species distribution within the population | |
Particle diversity of particle | Effective number of species in particle | |
Average particle (alpha) species diversity | Average effective number of species in each particle | |
Bulk population (gamma) species diversity | Effective number of species in the bulk | |
Mixing state metric | Degree to which population is externally mixed () versus internally mixed () |
In this study, we also used the metric adopted from our previous study (Wang et al., 2023) to quantify the CT distribution of BC aerosols during the simulation. Unlike , the metric emphasizes the thickness of the BC coating layer and characterizes the mixing state of BC aerosols based on the CT distribution. The unified framework governing the mixing state of BC aerosols reveals a consistent size distribution, indicating that the natural logarithm of the number concentration () and CT exhibits a linear relationship, regardless of the size of the BC core (Wang et al., 2023). In this study, the variable denotes the diameter of the BC core; the variable denotes the diameter of the particle; and CT signifies the coating thickness of the BC particle, which is defined as . Furthermore, (CT) represents the normalized number concentration of BC particles within the range of . The normalization is relative to the total number concentration of BC particles, rendering a dimensionless value. By performing linear regression, the relationship between the CT and the corresponding number concentration in logarithmic coordinates, , was established, and the slope was calculated by Eq. (). The detailed methodology for data processing is provided in Sect. S2.1. 1 Although the value of can be calculated using Eq. (), it is fundamentally determined by the deposition rate (Dep) or, more generally, the removal rate and the growth rate (GR), such that () (Wang et al., 2023). The slope was subsequently adopted as a characterization parameter to assess the BC mixing state, focusing on the particle size distribution. Per-particle size for statistical analysis was calculated using the component density from PartMC-MOSAIC output (Sect. S2.2 and Table S4) combined with the core–shell model (McGrory et al., 2022; Wang et al., 2019).
2.4 Light absorption enhancement of BC aerosolsThe optical properties of BC aerosols were characterized using light absorption enhancement in this study, which is defined as the ratio of the MAC of coated BC to bare BC. The calculations of were performed using the core–shell Mie method (Fu and Sun, 2001; Schwarz et al., 2008b; Toon and Ackerman, 1981). In this study, the wavelength was set to 550 nm and the refractive indices (RIs) of the BC and scattering components were set to (Moteki et al., 2023) and (Schwarz et al., 2015), respectively. Furthermore, the determination of is undertaken through two methods (per-particle method and -value method).
The per-particle method of computation entails the utilization of core–shell Mie theory to determine the optical properties of individual particles. Subsequently, statistical techniques were applied to derive the of the entire BC population. can be represented as Eq. ().
2 where represents the light absorption coefficients of the BC core with coating shell, and represents the light absorption coefficients of the BC core. Both and can be calculated directly through the core–shell Mie method with the given and of each particle simulated by the PartMC-MOSAIC model.
The -value method of calculating uses simplified and distributions, which obviates the need for individual particle calculations and greatly reduces the computational burden. The calculation is predicated on the provided probability density functions of and equivalent . The log-normal distribution of is set according to the initial emissions specified in the PartMC-MOSAIC model, with a mean diameter of 89 nm and a geometric standard deviation of 1.6 (Lee, 1983). The probability density function of equivalent is determined by incorporating the mean coating thickness (Wang et al., 2023), ascertained from the value, into the probability density function of (). More detailed information and calculations about the -value method were illustrated in the study of Wang et al. (2023).
The per-particle method involves computing the of the BC population by utilizing the MAC of each particle. The -value method of calculating uses simplified and distributions obtained from the steady CT distribution, which obviates the need for individual particle calculations and greatly reduces the computational burden. Since the per-particle method demonstrates high precision in determining , the accuracy of the -value method in calculating can be evaluated by comparing it with the per-particle method.
2.5 Determination of characteristic timeTo quantify the rate at which the BC mixing state reaches a steady state, we employ the characteristic time , as defined by the following equation.
3 where the metric(0) denotes the mixing state at the initial state, while the denotes the steady mixing state. In this study, we use the metric to characterize the mixing state. The steady-state characteristic time enables us to ascertain the timescale over which the mixing state reaches a steady state and facilitates a quantitative comparison of the differences across various cases.
3 Results3.1 The realism of the baseline case
To verify the realism of the baseline case simulated by the PartMC-MOSAIC model, we compare representative results of aerosol component mass fractions and CT distributions obtained from SP2 observations and model simulations. The representative results of aerosol component mass fractions from observations come from Wang et al. (2017), including mass concentrations of organic matter (OM), black carbon (BC), nitrate ion (), sulfate ion (), and ammonium ion (). The comparison is given in Table S2, showing that the simulated results are within the range of the observations (Wang et al., 2017). As the simulation does not involve crustal materials such as Ca and Na, the result that the positive ion is slightly beyond the range is reasonable. Since there are no sulfate-containing particles emitted and the sulfate production by in-cloud chemistry is not included, the primary source of is the conversion of gas to particles. As a result, the proportion of mass is relatively small, while levels are relatively high.
Then, we conduct a statistical analysis of the CT distribution based on the results from the baseline case simulation and SP2 observations in Nanjing. Figure 1 shows that the CT distribution derived from the PartMC-MOSAIC simulation closely matches that from SP2 observations, with both results following an exponential linear distribution (linear distribution on a logarithmic scale) and yielding the same slope value of 0.016 for the fitting curve, which confirms the realism of the scenario simulated by the PartMC-MOSAIC model.
Figure 1
The CT distribution of black carbon aerosols, determined from SP2 observation results (grey dots and line) and PartMC-MOSAIC simulation based on the observed scenario (red dots and line). Each dot indicates the total number of particles in the CT interval, and the linear regression of each distribution is represented by dashed lines.
[Figure omitted. See PDF]
3.2 The characteristic time of BC reaching a steady-state mixing stateAfter verifying the realism of the baseline case, we first explore whether a steady-state mixing state of BC aerosol can be achieved. Then, we use Eq. () to describe the progress of the mixing state metric reaching a steady state. The characteristic time for reaching a steady mixing state of the BC aerosols from the perspective of the criterion is investigated. We perform nonlinear fitting of the metric according to Eq. (), with given by the value at the start of the simulation and given by the average value of the final 48 h of the simulation. Figure 2 illustrates the evolution of the metrics and during the simulation. We discover that the mixing state metrics and tend to reach a steady state, with slight daily variations (Fig. 2a and b) due to periodic external drivers. Thus, we adopt a moving average algorithm (Hansun, 2013) over 24 h (Sect. S2.3) to eliminate such periodic influences on the mixing state. As shown in Fig. 2a, the characteristic time of the baseline case is 3.2 h, which corresponds to the rate of the mixing state reaching a steady state. In addition, we construct more cases by changing the settings of temperature and emissions of gas and particles based on previous relevant investigations (Bond et al., 2013; Lee, 1983; Moteki, 2023). The characteristic timescale ranges from 1.9 to 9.7 h (Table S3) for reaching a steady mixing state of the BC aerosols. Figure 2b shows the exponential linear fit slope of the CT distribution of BC aerosols. After 48 h, the absolute value of the slope becomes steady under the periodic influence, and the value after the moving average is steady at 0.016 . The coefficient of determination between and CT maintains a high value () during the simulation (Fig. S2), which demonstrates the stability of CT distribution over time.
Figure 2
The time evolution of the black carbon mixing state under the combined influence of continuous emissions and various atmospheric processes simulated by PartMC-MOSAIC during the 10 d simulation. (a) The time evolution of the metric (solid line), the metric after the simple moving average algorithm (dashed line), and (red line). (b) The time evolution of the metric (solid line) and the metric after the simple moving average algorithm (dashed line).
[Figure omitted. See PDF]
3.3 The exponential linear distribution of coating thickness and its reconciliation of non-uniform compositionFurther, we analyze the CT distribution of all BC aerosols during the steady-state period (after 48 h). Figures 1 and 3 provide the CT distribution under the steady state simulated by PartMC-MOSAIC. Figure 1 shows that the CT distribution of BC aerosols follows an exponential linear distribution. The coefficient of determination () between CT and is 0.999, indicating a strong linear relationship between them. The slope of the linear fitting is 0.016 . Equivalent to the reciprocal of , the mean coating thickness is 62 (Wang et al., 2023), which is only 1 lower than the value calculated by the per-particle method ( 63 ). The results of CT distribution and comparison are listed in Table S3 and Fig. S3. Figure 3 shows the CT distribution results of BC aerosols, classified by the size of the BC core (). Four bins (50–70, 70–90, 90–110, and 100–130 nm) were selected, accounting for 68 % of the total number concentration of BC aerosols. The CT distributions with different have approximately the same slope of and CT, with comparable values ranging from 0.0160 to 0.0164 (Fig. 3). The above results verify that the CT distribution of BC aerosols under the steady-state condition follows the exponential linear distribution and exhibits characteristics that are not dependent on (Fig. 3). The exponential CT distribution of BC aerosols can effectively reflect the distribution pattern of the coating layer and is more precise than simple assumptions such as the fully internal mixture of BC aerosols.
Figure 3
The statistical CT distribution of BC aerosols during the steady-state period (after 48 h) simulated by PartMC-MOSAIC. The CT distributions of four selected ranges follow the exponential linear distribution law, represented by dots with different colors. Each dot indicates the total number of particles that are in the CT interval. The linear regression of each distribution is represented by dashed lines, with normalized by the total number concentration for each bin. Normalization does not influence the slope but only affects the intercept of the line (Sect. S2.1).
[Figure omitted. See PDF]
Different statistical methods can reveal different facets of the BC mixing state. Fierce et al. (2016) found that across the entire diverse BC population, most of the coating material is contained in particles that have small amounts of BC mass, while most of the BC mass resides in particles with large BC inclusions and thin coatings. The conclusion showed the non-uniform composition of BC aerosols, which seems inconsistent with the exponential linear distribution of CT independent of BC core size in our paper. Here we explain how to understand that both findings are consistent and how to utilize the exponential linear distribution of CT to parameterize the non-uniform composition of BC and non-BC components through Fig. 4 and Eqs. () and ().
The distribution of follows a log-normal distribution with a mean diameter of 89 nm and a geometric standard deviation of 1.6. The distribution of CT follows an exponential linear distribution (Fig. 4a), provided by Eq. (). 4 where the value of is related to the total particle number concentration of BC-containing particles, and represents the slope of the exponential linear CT distribution. For statistical convenience, we normalize to make its integral over CT equal to 1; hence the value equals . Because of the self-similarity of CT distributions (Fig. 3), different bins share the same CT distribution. Based on the distribution of CT and , we obtain the volume fraction (VF) distribution of the BC component with respect to , provided by Eq. (). 5 The derivative of the equation with respect to , , is greater than 0, which indicates that for a fixed CT distribution, VF monotonically increases with and BC mass of each particle. The ideal results obtained from the -value method (exponential linear distribution of CT) corroborate the actual results from PartMC-MOSAIC simulation (Fig. 4b). Then, we use the VF of BC with respect to the mass of BC contained in each particle to obtain the distribution of BC and non-BC components (Fig. 4c), which shows that components account for a smaller proportion in the range of larger BC cores and a larger proportion in the range of smaller BC cores; i.e., the volume (or mass) fraction of coating is not uniform across the BC cores. Based on the PartMC-MOSAIC simulation, we calculated the mass distribution of aerosol components directly and compared it with that under the uniform assumption (Fig. 4d). The results show that the distribution of aerosol components with respect to the mass of BC contained in each particle is non-uniform, and it is highly consistent with that obtained from the -value method in Fig. 4c, which confirms that the aerosol composition results derived from the exponential linear distribution of CT are indeed consistent with the non-uniformity result (Fig. 4d). The derivation mentioned above demonstrates that the exponential linear CT distribution of BC aerosols proves the non-uniform composition of BC aerosols from another perspective and can serve as a suitable statistical method for parameterizing non-uniform composition and characterizing the BC mixing state.
Figure 4
The reconciliation of the exponential linear CT distribution and the non-uniform composition of BC aerosols. (a) The exponential linear CT distribution of BC aerosols with a slope of 0.016 under the steady state obtained from a PartMC-MOSAIC simulation. (b) The per-particle volume fraction of BC components and non-BC components with respect to per-particle BC mass. (c) The mass distribution of BC and non-BC components derived from the log-normal distribution of and the exponential linear distribution of CT (). (d) The mass distribution of aerosol components, normalized by dividing each component's mass by the total particle mass, with respect to the BC mass in each particle, was determined using the statistical method of Fierce et al. (2016) based on the results obtained from the PartMC-MOSAIC simulation. The values on the axis in panels (c) and (d) have been normalized: .
[Figure omitted. See PDF]
3.4 The application of the -value method in BC absorptionBased on the above results, we hypothesize that the exponential linear CT distribution of BC aerosols can serve as an accurate, simplified characterization of the BC mixing state under the steady-state condition. To verify its application in optical calculations, we follow the evolution of calculated by utilizing the -value method and compare it with the real result obtained from the per-particle method, as illustrated in Fig. 5. Through this comparison, we observe a minimal deviation between the -value results and the true values. Specifically, the mean squared error (MSE) is 0.001, the root mean squared error (RMSE) is 0.039, and the mean absolute error (MAE) is 0.029. These metrics indicate that the time evolution of from both methods shows a high degree of consistency, which verifies the viability of the method that utilizes the CT distribution to obtain the BC light absorption amplification. Additionally, Fig. 5 shows that the reaches a steady state after 48 , fluctuating regularly in the range of 1.4 to 1.5, which is consistent with observations ranging from 1.0 to 1.7 (Cappa et al., 2012, 2019; Knox et al., 2009; Lack et al., 2012; Liu et al., 2015; Ma et al., 2020; Ueda et al., 2016). Overall, the light absorption amplification of BC aerosols remains steady under the steady-state condition, and the -value method based on the steady-state theory can be used effectively as a simplified mixing state scheme for optical calculations of BC aerosols.
Figure 5
The time evolution of BC light absorption enhancement () calculated by the per-particle method and -value method during the simulation for the baseline case. The black lines and red lines represent the calculated by the per-particle method and -value method, respectively.
[Figure omitted. See PDF]
4 DiscussionWe discuss the potential utility of steady-state theory for modeling efforts and its application scopes. The slope parameter denotes the CT distribution of BC aerosols under steady state. According to the derivation presented by Wang et al. (2023), the value of was determined to be equivalent to the average CT of BC aerosols (Table S3). The relationship between and CT is approximately linear when CT is less than 200 nm () (demonstrated in the Fig. S3 of Wang et al., 2023). Therefore, a monodisperse CT, , can replace the BC coating thickness distribution when calculating the BC absorption. Figure 5 in this paper shows that the based on the steady-state theory can serve as a characterization of the light absorption enhancement of BC aerosols under the steady-state condition. The value can be obtained from the growth rate and removal rate ( thus efficiently helping evaluate the BC absorption. Regarding the application of the slope in models, we propose utilizing existing state values in models, such as the total mass concentration of each component combined with the distribution of coating thickness and diameter of the BC core, to build a parameterized framework of the value based on the studies by Chen et al. (2023, 2024), which is an avenue for future research. Furthermore, we plan to employ machine learning techniques to develop an emulator for the value based on training data obtained from PartMC-MOSAIC. In this approach, the value will serve as the “label”, while emissions, initial conditions, and meteorological conditions will be treated as “features”. This method is inspired by the study by Zheng et al. (2021), which used the metric as the “label” for their emulator. Further, the characteristic timescale for BC reaching a steady-state mixing state ranges from 1.9 to 9.7 h, which is considerably shorter than their atmospheric lifetime, typically around 7 d. Thus, the steady-state assumption may effectively be applied to climate models, which are generally concerned with the characteristics of BC aerosols across extensive spatial and temporal scales. It may be not applicable for high-resolution modeling studies of urban areas wherein fresh BC emissions are continuously added, which may influence the steady state. In these conditions, we propose that, categorizing BC-containing particles into fresh BC and aged BC (Liu et al., 2016), fresh BC follows a log-normal distribution, and the coating layer of aged BC follows an exponential liner distribution. The slope parameter is capable of characterizing the distribution of the latter. Hence, the -value method can be applied in models for BC absorption under the steady-state condition.
5 Conclusions
Our study simulated the time evolution of the BC mixing state under continuous emission, condensation, coagulation, and deposition processes using the PartMC-MOSAIC model. The baseline case is based on SP2 measurements, model simulations, and field observations, which has been verified for realism. Furthermore, based on the baseline case, we altered the pollution conditions (emission of aerosols and gas) and temperature conditions to simulate 12 additional cases. The steady-state behavior of the BC mixing state under the joint influence of emissions and atmospheric processes was confirmed for each case. During the simulation, the characteristic time for BC aerosols to reach a steady mixing state in the baseline scenario was 3.2 h, with a range from 1.9 to 9.7 h under different emissions of gases and particles and different temperature conditions. In addition, the CT distributions of BC aerosols in all cases followed an exponential linear distribution. Taking the baseline case as an example, the slope of the linear fitting was 0.016 (with a correlation coefficient, , of 0.999 during steady state), and the equivalent mean coating thickness was 62 nm, close to the value ( 63 ) calculated by the per-particle method. Based on the CT distribution, we reconciled our finding with the non-uniform composition of BC particles that has been documented in previous studies. Moreover, our study found that the numerical values of derived from the -value method are highly consistent with the real values calculated by the per-particle method during the simulation. Therefore, the based on the steady-state theory can serve as a characterization of the light absorption enhancement of BC aerosols under the steady-state condition. We successfully simplified the continuous variation of the BC mixing state and obtained a precise evaluation of the optical properties of BC aerosols based on the steady-state theory, approaching the accuracy level of the particle-resolved model. Finally, we discuss the application of the steady-state theory in global models, highlighting its application scope: specifically, the analysis of the average properties of BC across extensive spatial and temporal scales. This study has proved the importance and precision of utilizing the steady-state theory to characterize the BC mixing state and assess its optical properties, which provides a robust foundation for further research and applications.
Code and data availability
The processed data, scripts, and setup of scenarios are available from 10.5281/zenodo.13997459 (Z. Zhang et al., 2024). PartMC version 2.5.0, used for the simulations in this paper, was introduced by Riemer et al. (2009; 10.1029/2008JD011073) and is available at
The supplement related to this article is available online at
Author contributions
JianW designed and directed the study. ZZ contributed to data analysis and wrote the first draft of this paper. JC, YJ, ZT, YC, and GC helped proofread the grammar of an earlier draft of the article. JiapW, ZT, and BW collected data. JianW, JiapW, NR, CL, and AD contributed the data interpretation and review of the paper.
Competing interests
The contact author has declared that none of the authors has any competing interests.
Disclaimer
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.
Acknowledgements
We appreciate Rahul A. Zaveri for the support of the MOSAIC aerosol model. We acknowledge the High Performance Computing Center of Nanjing University of Information Science and Technology for their support of this work.
Financial support
This work was supported by the National Natural Science Foundation of China (grant nos. 42422505, 42475116, and 42075098) and the National Key Research and Development Program of China (grant no. 2022YFC3701000, Task 5). Nicole Riemer was funded by the DOE grant DE-SC0022130.
Review statement
This paper was edited by Ari Laaksonen and reviewed by two anonymous referees.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2025. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Black carbon (BC) exerts a notable warming effect due to its strong light absorption, largely influenced by its “mixing state”. However, due to computational constraints, the mixing state is challenging to accurately represent in large-scale models. In this study, we employ a particle-resolved model to simulate the evolution of BC mixing state based on field observation. Our result shows that aerosol compositions, coating thickness (CT) distribution, and optical properties of BC aerosols all exhibit a tendency toward a steady state with a characteristic timescale of less than 1 d, considerably shorter than the BC atmospheric lifetime. The rapid attainment of a steady state suggests that it is reasonable to disregard this pre-steady-state period and instead concentrate on the average properties of BC across extensive spatial and temporal scales. The distribution of CT follows an exponential linear distribution and can be characterized by a single slope parameter
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details




1 State Key Laboratory of Climate System Prediction and Risk Management/Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters/China Meteorological Administration Aerosol-Cloud and Precipitation Key Laboratory, Nanjing University of Information Science and Technology, Nanjing 210044, China; School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044, China
2 Joint International Research Laboratory of Atmospheric and Earth System Sciences, School of Atmospheric Sciences, Nanjing University, Nanjing 210023, China; National Observation and Research Station for Atmospheric Processes and Environmental Change in Yangtze River Delta, Nanjing 210023, China
3 Department of Climate, Meteorology, and Atmospheric Sciences, University of Illinois Urbana-Champaign, 1301 W Green St., Urbana, IL 61801, USA
4 State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China