Abstract

Cardiac implantable electronic devices (CIEDs) were believed to have a tolerance dose and that direct irradiation has to be avoided. Thus, no clinical guidelines have mentioned the feasibility of total body irradiation (TBI) with a CIED directly. The purpose of this work was to study a feasible and safe condition for TBI using a CIED. Eighteen CIEDs were directly irradiated by a 6-MV X-ray beam, where a non-neutron producible beam was employed for the removal of any neutron contribution to CIED malfunction. Irradiation up to 10 Gy in accumulated dose was conducted with a 100-cGy/min dose rate, followed by up to 20 Gy at 200 cGy/min. An irradiation test of whether inappropriate ventricular shock therapy was triggered or not was also performed by using a 6-MV beam of 5, 10, 20 and 40 cGy/min to two CIEDs. No malfunction was observed during irradiation up to 20 Gy at 100 and 200 cGy/min without activation of shock therapy. These results were compared with typical TBI, suggesting that a CIED in TBI will not encounter malfunction because the prescribed dose and the dose rate required for TBI are much safer than those used in this experiment. Several inappropriate shock therapies were, however, observed even at 10 cGy/min if activated. The present result suggested that TBI was feasible and safe if a non-neutron producible beam was employed at low dose-rate without activation of shock therapy, where it was not inconsistent with clinical and non-clinical data in the literature. The feasibility of TBI while using a CIED was discussed for the first time.

Details

Title
Study of feasible and safe condition for total body irradiation using cardiac implantable electronic devices
Author
Matsubara, Hiroaki 1 ; Takatomo Ezura 2 ; Hashimoto, Yaichiro 1 ; Karasawa, Kumiko 1 ; Nishio, Teiji 1 ; Tsuneda, Masato 1 

 Department of Radiation Oncology , Tokyo Women’s Medical University, Tokyo 162-8666, Japan 
 Department of Radiology , Tokyo Women’s Medical University Hospital, Tokyo 162-8666, Japan 
Pages
1006-1014
Publication year
2021
Publication date
Nov 2021
Publisher
Oxford University Press
ISSN
04493060
e-ISSN
13499157
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3171180133
Copyright
© The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. This work is published under https://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.