In cryogenic gravitational-wave detectors, one of the most important issues is the fast cooling of their mirrors and keeping them cool during operation to reduce thermal noise. For this purpose, the correct estimation of thermal-radiation heat transfer through the pipe-shaped radiation shield is vital to reduce the heat load on the mirrors. However, the amount of radiation heat transfer strongly depends on whether the surfaces reflect radiation rays diffusely or specularly. Here, we propose an original experiment to distinguish between diffusive and specular surfaces. This experiment has clearly shown that the examined diamond-like carbon-coated surface is specular. This result emphasizes the importance of suppressing the specular reflection of radiation in the pipe-shaped shield.

Details

Title
An experiment to distinguish between diffusive and specular surfaces for thermal radiation in cryogenic gravitational-wave detectors
Author
Sakakibara, Yusuke 1 ; Kimura, Nobuhiro 2 ; Suzuki, Toshikazu 2 ; Yamamoto, Kazuhiro 1 ; Tokoku, Chihiro 3 ; Uchiyama, Takashi 1 ; Kuroda, Kazuaki 1 

 Institute for Cosmic Ray Research (ICRR), University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8582, Japan 
 High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan 
 Research Center for Electron Photon Science, Tohoku University, 1-2-1 Mikamine, Taihaku-ku, Sendai, Miyagi 982-0826, Japan 
Publication year
2015
Publication date
Jul 2015
Publisher
Oxford University Press
e-ISSN
20503911
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3171473109
Copyright
© The Author(s) 2015. Published by Oxford University Press on behalf of the Physical Society of Japan. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.