Full text

Turn on search term navigation

© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Steatotic liver disease is a global health challenge that requires reliable and noninvasive diagnostic biomarkers. This research aimed to validate the analytical and clinical performance of a fibroblast growth factor 21 (FGF21) enzyme-linked immunosorbent assay (ELISA) kit using an automated immunoassay analyzer. Plasma FGF21 levels were measured using a commercial ELISA kit on an automated immunoassay analyzer. Validation included intra- and inter-assay precision, dilution linearity, spike recovery, lower limit of quantification (LLOQ), interference testing, and sample stability analysis. Clinical evaluation involved 97 patients who underwent abdominal ultrasound-based attenuation imaging for the diagnosis of hepatic steatosis. The assay demonstrated high analytical precision, with intra- and inter-assay coefficients of variation <15% and an LLOQ of 3.260 pg/mL. Dilution linearity, spike recovery, and interference tests confirmed the reliability of the assay, whereas stability tests highlighted the minimal effect of freeze-thaw cycles and storage conditions. Clinically, FGF21 levels correlated with attenuation coefficient (r = 0.44). Diagnostic performance indicated 84% sensitivity and 81% specificity at defined FGF21 thresholds for the diagnosis of hepatic steatosis. This research confirmed the reliable analytical and clinical performance of the FGF21 ELISA kit, reinforcing its potential as a diagnostic biomarker of hepatic steatosis.

Details

Title
Analytical and Clinical Validation of a Plasma Fibroblast Growth Factor 21 ELISA Kit Using an Automated Platform in Steatotic Liver Disease
Author
Tanaka Makito 1 ; Tanaka, Shingo 1 ; Kobayashi Ryo 2   VIAFID ORCID Logo  ; Murai Ryosei 2   VIAFID ORCID Logo  ; Takahashi, Satoshi 1 

 Division of Laboratory Medicine, Sapporo Medical University Hospital, Sapporo 060-8543, Japan; [email protected] (M.T.); [email protected] (R.K.); [email protected] (R.M.); [email protected] (S.T.), Department of Infection Control and Laboratory Medicine, Sapporo Medical University School of Medicine, Sapporo 060-8543, Japan 
 Division of Laboratory Medicine, Sapporo Medical University Hospital, Sapporo 060-8543, Japan; [email protected] (M.T.); [email protected] (R.K.); [email protected] (R.M.); [email protected] (S.T.) 
First page
877
Publication year
2025
Publication date
2025
Publisher
MDPI AG
e-ISSN
2218273X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3223879771
Copyright
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.