Abstract
Transthoracic electrical bioimpedance (TEB) has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO) measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India) and compared it with thermodilution (TD) method in patients after off-pump coronary artery bypass (OPCAB) graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous) on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 +- 0.85 L/min), while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 +- 0.94 L/min). The average correlation (r) was 0.548 (P = 0.0002), accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 +- 0.76 L/min), while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 +- 0.82 L/min). Their average correlation was relatively poor (r = 0.469, P= 0.002), accompanied by a bias of -0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation) and 17.4% (during spontaneous breathing), respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer





