Abstract
Context: The use of spirometry is currently limited to the diagnosis of obstructive airway disease for tertiary centers mainly because of the unmet need for technical expertise and funding. Use in primary care asks for a simpler and cost-effective screening tool for obstructive airway disease. Aim: To estimate the efficacy of FEV6 against the current standard of FVC in the spirometric diagnosis of obstructive airway disease. Setting and Design: The Pulmonary Function Laboratory of a tertiary care hospital in Coastal South India. It was a descriptive study. Materials and Methods: We analyzed 150 serial patients on ATS standardized spirometers. The patients were classified into normal subjects and those with airway obstruction, further categorized as mild, moderate and severe and those with mixed defect. Those with obstruction were also classified as having reversible and irreversible defects. Statistical Analysis: Data was analyzed using SPSS Software (v.11.5), statistical test ANOVA and Pearson correlation was done and P less than 0.05 considered statistically significant. Results: FVC and FEV6 showed a linear correlation in all subjects. The difference in means was statistically significant in all subjects. The sensitivity and specificity of FEV1 /FEV6 in comparison to FEV1 /FVC were both found to be 100%. Conclusion: FEV6 is an excellent screening tool in the diagnosis of airway obstruction but, there is a necessity for further research to confirm our findings. There is also a need for reference values in an Indian setting to find out the efficiency of this new parameter. Our sample size is relatively small and comprises of a very high proportion (70%) of subjects with airway obstruction and so our results may not be applicable for use in general population.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer