It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background: The purpose of this prospective study was to investigate the intraocular pressure (IOP)-lowering effect and safety of latanoprost 0.005% + timolol maleate 0.5% fixed combination eyedrops, now available in Japan.
Materials and methods: Thirty-one patients diagnosed with primary open-angle glaucoma who had an insufficient intraocular pressure (IOP) decrease with latanoprost 0.005% eyedrop monotherapy were enrolled. The latanoprost 0.005% eyedrops were discontinued, and administration of latanoprost 0.005%/timolol maleate 0.5% fixed combination eyedrops was initiated without any washout period. IOP was compared before and at months 1, 3, and 6 after the switch. The incidence of adverse reactions was investigated at every follow-up visit.
Results: Mean IOP was 17.3 ± 2.7 mmHg before the switch, 15.5 ± 2.6 mmHg one month after the switch, 14.9 ± 2.4 mmHg 3 months after the switch, and 15.1 ± 2.2 mmHg 6 months after the switch, indicating that IOP decreased significantly after the change. The IOP reduction rate was 9.9% ± 11.5% after one month, 13.1% ± 10.9% after 3 months, and 11.2% ± 11.8% after 6 months. Two patients (6.5%) discontinued therapy due to adverse reactions (one case each of itchiness and bradycardia).
Conclusion: When latanoprost 0.005% eyedrop monotherapy was replaced by latanoprost 0.005% + timolol maleate 0.5% fixed combination eyedrops, IOP decreased significantly without increasing the frequency of administration, and safety was satisfactory.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer