Academic Editor:Guillermo Rus
1, Steel Solution Center, POSCO, 100 Songdogwahak-ro, Yeonsu-gu, Incheon 406-840, Republic of Korea
Received 24 September 2014; Accepted 24 November 2014; 3 June 2015
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Many structures use external tendons including the main and hanger cables for suspension bridges as well as the main cables for cable-stayed bridges, stranded cables, external reinforcing cables. External tendons use the tensile force applied to the cable, and it is used as the main or sub-members for many structures. The tensile force of the external tendon applied during the construction phase varies over time after completion depending on various factors. Therefore, to estimate the tensile force of the external tendon is of a paramount importance in terms of the stability and maintenance of a structure. The most accurate means to estimate the tension on the cables is to use load cells to collect the data directly. However, this is not an option in many cases due to the conditions in the field and the higher price of the cells and short service lives of these components, which can be a maintenance challenge when malfunctions occur. Therefore, the most commonly used method is to extract the natural frequency from the acceleration signal measures and enter the data into an equation that shows the relationship between the natural frequency and tension, to estimate the tension indirectly.
The two most widely used methods are the taut string theory [1] which does not take the bending stiffness into consideration and the linear regression method [2-4] which regards the cable as a beam under the axial load and considers the bending stiffness. The estimation methods for tension using the existing dynamic method put the natural frequency values to the equation on the natural frequency and tension. Therefore, if the mathematical model used differs significantly from the actual structure, a significant error is unavoidable.
The method of estimating the tensile force of external tendons we introduce in this paper has the following two outstanding characteristics. First, since it uses the finite element model, it can be applied to any form of external tendon because when the structure is geometrically complex and difficult to determine the value of a mathematical model, the finite element model is the most effective alternative. That is, the natural frequencies of the structure can be calculated using the finite element model but not analytical methods. Second, when the number of variables to be identified is large, the methods to minimize the error between the calculated natural frequency and the measured natural frequency involve a lot of computation. For this reason, we applied the system identification method that uses the sensitivity analysis, which is garnering greater attention these days. The overall diagram for the process of estimating the tensile force using the system identification method is shown in Figure 1, and further details can be found in the studies by Park and Kim [5] and Park et al. [6]. In this study, the theoretical formulation of tension estimation is carried out through the system identification technique that uses the sensitivity updating algorithm, which is then applied to the benchmark numerical examples, laboratory test samples, and the field structures to verify the effectiveness of our method.
Figure 1: The process of estimating the tensile force using the system identification method [5].
[figure omitted; refer to PDF]
2. Theoretical Formulation
In the process of estimating the tension using the system identification approach based on the finite element model, the tension of external tendons is illustrated by the identification vector which is composed of several unknown parameters. The identification vector containing unknown parameters [figure omitted; refer to PDF] ( [figure omitted; refer to PDF] ) used for identifying the tensile force in the system identification procedure can be defined as [figure omitted; refer to PDF] where [figure omitted; refer to PDF] denote the identification variables for estimating tensile force. For example, the [figure omitted; refer to PDF] could be set to the tension or other physical property for external tendons, that is, need to identify.
The identification vector for the r th iteration in the sensitivity-based updating algorithm can be assumed as [figure omitted; refer to PDF] where [figure omitted; refer to PDF] mean the identification variables for the r th iteration.
Then, the static displacement and tendon force distribution can be produced for the identification vector. In the next step, the natural frequency [figure omitted; refer to PDF] ( [figure omitted; refer to PDF] ) is determined from the finite element vibration analysis using the static displacement curve and tendon force distribution. Using the change in natural frequencies for different identification variables, the sensitivity matrix ( [figure omitted; refer to PDF] ) with [figure omitted; refer to PDF] size can be determined approximately as follows: [figure omitted; refer to PDF]
Then, from the produced natural frequency data, the rate of change ( [figure omitted; refer to PDF] ) for the eigenvalue can be obtained as [figure omitted; refer to PDF] where [figure omitted; refer to PDF] and [figure omitted; refer to PDF] denote the [figure omitted; refer to PDF] th mode's natural frequency measured from experiment or field test and the [figure omitted; refer to PDF] th mode's frequency calculated from nonlinear finite element vibration analysis using [figure omitted; refer to PDF] in the [figure omitted; refer to PDF] th iteration, respectively. Equation (4) can be rewritten in the vector form as [figure omitted; refer to PDF]
Equation (5) is referred to as a linear sensitivity equation, and the rate of change for the identification vector by using (5) can be expressed as [figure omitted; refer to PDF] where [figure omitted; refer to PDF] means the pseudoinverse matrix for [figure omitted; refer to PDF] and can be determined as [figure omitted; refer to PDF]
Finally, the [figure omitted; refer to PDF] th identification variable in the ( [figure omitted; refer to PDF] )th iteration can recalculated as [figure omitted; refer to PDF] From (2) to (8), the loop is repeated until the termination condition is satisfied. The convergence condition for the repetition analysis uses the square roots of the sum of square (SRSS) in the following: [figure omitted; refer to PDF]
Finally, tensile force is determined from the identification variables holding at the termination stage and relevant natural frequencies can be determined through the finite element vibration analysis with the identification variables.
To identify the mode shape number of measured natural frequency, a number of sensors are required in the system identification approach based on the finite element model.
However, few sensors (e.g., less than 4 sensors) are enough to get the required number of natural frequency with mode shape (e.g., 2 or 3 modes) in this approach. Furthermore, the sensor location can be varied when there are a limited number of sensors.
The tension estimation results will be compared with existing methods, that is, taut string theory and linear regression method and the governing equations of these two methods are shown as [figure omitted; refer to PDF] where [figure omitted; refer to PDF] , [figure omitted; refer to PDF] , and [figure omitted; refer to PDF] are mass per unit length, effective length, and flexural rigidity, respectively.
3. Benchmark Numerical Examples
Before the field application of the tension estimation method using the system identification technique, we developed the benchmark example shown in Figure 2 to verify the development theory. In this case, the bending stiffness and boundary conditions of the cable were changed as shown in Table 1 to validate the advantages of the newly developed theory compared to existing ones.
Table 1: Variation of parameter for benchmark numerical examples.
Cable ID | Bending stiffness (N-m2 ) | Boundary condition |
C1 | 100 | Hinged-Hinged |
C2 | 1000 | Hinged-Hinged |
C3 | 1000 | Fixed-Fixed |
Figure 2: Benchmark numerical examples.
[figure omitted; refer to PDF]
The purpose of C1 and C2 in Table 1 is to check the influence of the bending stiffness, while C2 and C3 are to see the influence of the boundary conditions. For each of the cables, the theoretical first through third natural frequencies are shown in Table 2.
Table 2: Natural frequencies calculated from benchmark numerical examples (Hz).
Cable ID | 1st | 2nd | 3rd |
C1 | 18.26 | 36.57 | 54.79 |
C2 | 18.33 | 37.09 | 56.69 |
C3 | 19.44 | 39.33 | 60.12 |
Table 3 shows the results of the tensile force estimations for the three benchmark cables using the taut string theory, the linear regression method, and the newly developed method. As shown in Table 3, the taut string theory, which is in capable of considering the bending stiffness, shows the errors in the estimated tensile forces as the bending stiffness increases (C1 to C2.) For tension estimations through the taut string theory and linear regression method, the boundary conditions cannot be considered, which resulted in a significant error in the C3 cable. Also, as the string theory has only one natural frequency, it can estimate the tensile force differently depending on the mode of natural frequency used even under the same tensile force. Therefore, when there is a difference in the natural frequency used in the field without the identification of the natural vibration mode, a big error is inevitable. On the other hand, the method of system identification considers the physical properties and boundary conditions, including bending stiffness. Therefore, the numerical example demonstrated that it is able to estimate the tensile force with precision. In addition, we used the SRSS (square root of sum of square) of the converged errors of the natural frequencies during the field application, which allowed us to indirectly verify the reliability of the estimated tensile force.
Table 3: Tension estimations error (%) of the benchmark examples.
Cable ID | Taut string theory | Linear regression method | System identification method (this study) | |
C1 | 1st 2nd 3rd | 0.08 0.32 0.71 | 0.00 | 0.00 |
| ||||
C2 | 1st 2nd 3rd | 0.08 3.16 7.11 | 0.00 | 0.00 |
| ||||
C3 | 1st 2nd 3rd | 13.32 16.01 20.47 | 12.43 | 0.00 |
Since the tension estimation method using the system identification technique is based on the finite element model, it is possible to estimate not only the tensile force but also the effective length, unit mass, and bending stiffness. It is also capable of estimating single and multiple variables simultaneously. Table 4 shows the results of estimation of multiple variables for the cable C2 in Table 1.
Table 4: Estimation error (%) of multiple variables for the cable C2.
Identification variable | Estimation error |
[figure omitted; refer to PDF] | [figure omitted; refer to PDF] , [figure omitted; refer to PDF] |
[figure omitted; refer to PDF] | [figure omitted; refer to PDF] , [figure omitted; refer to PDF] |
[figure omitted; refer to PDF] | [figure omitted; refer to PDF] , [figure omitted; refer to PDF] |
[figure omitted; refer to PDF] | [figure omitted; refer to PDF] , [figure omitted; refer to PDF] , [figure omitted; refer to PDF] |
Estimation of the multiple variables can reduce errors in the estimation of tensile force, as it can indirectly determine the variable that significantly affects the errors in estimating the tensile force (effective length, boundary conditions, and equivalent unit mass)
4. Application to Laboratory Test Samples
Before we applied the newly developed method that was verified by means of the benchmark numerical example, we applied this new method to two test samples to identify possible problems that might occur during field applications and complement them as necessary.
4.1. Strand Cable Test Sample
Strand cables are composed of 7 smaller wires and are usually the basic element to make PC steel strands or cables for cable stayed bridges and suspended cables. Depending on the application, some strands use additional fillers or shielding to prevent them from being corroded, as shown in Figure 3. The steel strand cable used in this study was a seven-strand cable used for PC steel strand cables, and it had no fillers or shielding.
Figure 3: Seven-strand cables.
(a) No shielding
[figure omitted; refer to PDF]
(b) Shielding
[figure omitted; refer to PDF]
To check the estimation effect of the tension due to the changes in tension as shown in Figure 4, we used a 3000-kN actuator that was located in the POSCO steel structure testing center. To measure the signals of acceleration, as shown in Figure 5, we added four accelerometers to the strand cable. The acceleration signal was transmitted to the computer through a wireless logger.
Figure 4: Test set-up.
[figure omitted; refer to PDF]
Figure 5: Vibration measurement set-up.
[figure omitted; refer to PDF]
The load was applied in 4 steps. The natural frequency based on the natural vibration mode extracted from the acceleration signals are shown in Table 5. Here, tests 1 and 4 failed to identify the third natural vibration mode.
Table 5: Applied tension and extracted natural frequencies.
Test ID | Applied tension (ton) | Extracted natural frequencies (Hz) |
Test 1 | 4.05 | 21.36, 42.94 |
Test 2 | 8.73 | 30.88, 61.87, 93.41 |
Test 3 | 13.46 | 38.07, 76.35, 114.80 |
Test 4 | 18.35 | 44.31, 88.68 |
As shown in Table 6, the technique of estimating the tensile force using the system identification method turned out to have less errors in terms of tensile force estimation compared to the taut string theory or linear regression method. This is because the existing theories could not consider the boundary conditions of the strand cable or the bending stiffness.
Table 6: Applied tension estimation error (%) of strand cables.
Test ID | Taut string theory | Linear regression method | System identification method (this study) | |
Test 1 | 1st 2nd | 11.68 12.83 | 11.29 | 0.70 |
| ||||
Test 2 | 1st 2nd 3rd | 8.09 8.48 9.90 | 7.74 | 0.05 |
| ||||
Test 3 | 1st 2nd 3rd | 6.61 7.20 7.72 | 6.56 | 0.35 |
| ||||
Test 4 | 1st 2nd | 5.92 6.07 | 5.87 | 0.62 |
4.2. Laboratory-Scale Cable-Stayed Bridge Test Sample
In addition to the strand cable test sample, we conducted the tensile force estimation experiment with a laboratory-scale test sample of a cable-stayed bridge as shown in Figures 6 and 7. In this case, the cable used was shielded steel strand cable, with a tensile force of 30 kN.
Figure 6: Laboratory-scale cable-stayed bridge test sample.
[figure omitted; refer to PDF]
Figure 7: Vibration test with a laboratory-scale test sample of a cable-stayed bridge.
[figure omitted; refer to PDF]
To examine the influence on the estimation of the tensile force by the setup of the vibration measurement, we altered the positions of the accelerometers, the hitting point of the impact hammer, and the time of measuring the vibration, in four separate test scenarios.
As carried out in the case of the strand cable test, we extracted three natural frequencies for each test. Figure 8 shows the extracted natural vibration modes for test 1. Based on these frequencies, we estimated the tensile force as shown in Table 7, which also shows the technique for estimating the tensile force using the system identification method. This turned out to have fewer errors in terms of tensile force estimation compared to the taut string theory or the linear regression method, as with the case of steel strand cables.
Table 7: Tension estimation error (%) of a laboratory-scale test sample of a cable-stayed bridge.
Test ID | Taut string theory | Linear regression method | System identification method (this study) | |
Test 1 | 1st 2nd 3rd | 12.95 13.98 16.59 | 12.35 | 1.49 |
| ||||
Test 2 | 1st 2nd 3rd | 12.95 14.24 16.94 | 12.36 | 1.60 |
| ||||
Test 3 (Test 4) | 1st 2nd 3rd | 14.24 14.24 17.03 | 13.44 | 2.19 |
Figure 8: Extraction of natural vibration mode for test 1.
[figure omitted; refer to PDF]
5. Field Application
We verified the feasibility of the system identification method, which was verified by the tests with laboratory-scale test samples, by estimating the tensile forces in the field.
5.1. Stay-Cable of Yeongdeok Number 1 Bridge
The first test in the field was conducted with the cables in a cable-stayed bridge, for which the tension estimations in the field were being performed using existing theories (string theory, linear regression). Yeongdeok number 1 Bridge is a cable-stayed bridge located in Giheung district, Youngin-si, Gyounggi-do. This bridge uses PPWS (prefabricated parallel wire strands) cables.
We estimated the tensile forces of 12 cables on both sides of the bridge as shown in Figure 9 and compared the estimation results from the existing methods and new method. Figure 10 shows that the force estimation made by the system identification method has errors not exceeding 5%. However, the existing methods, in some cases, showed a high level of errors. However, the methods of estimating the tensile force using the existing theories also yielded relatively desirable outcomes. This is because the length of cable stays of the bridge is within a range from 44 m to 95 m, which is relatively long and similar to the assumptions used in the existing theories.
Figure 9: Yeongdeok number 1 cable-stayed bridge.
[figure omitted; refer to PDF]
Figure 10: Tension estimation error (%) of Yeongdeok number 1 stay-cable.
[figure omitted; refer to PDF]
The tension estimation method using the system identification shown in Table 8 has a relatively smaller standard deviation for the estimation errors compared to those of the existing theories. Therefore, the tensile forces are able to be estimated with more reliability.
Table 8: Mean and standard deviation (%) of tension estimation errors for stay-cable.
Method | Mean | Standard deviation |
Taut string theory | 4.42 | 4.59 |
Linear regression method | 4.14 | 4.29 |
System identification method (this study) | 1.95 | 1.59 |
5.2. External Tendon for the Approach Bridge Section of Incheon Grand Bridge
The external tendon for normal bridges is applied during the construction phase or afterwards for reinforcing the structure. To check the applicability of the system identification method for such external tendons, we applied this method to the external tendons of the approach bridge section of the Incheon Grand Bridge. The external tendons, unlike cables in cable-stayed or suspension bridges, installed deviation blocks, or vibration preventing device between the external tendons, as shown in Figure 11. Also, the external tendon was shielded in HDPE pipes and the interior was filled with mortar to prevent corrosion. Therefore, it was difficult to apply the existing theories, and there is no other way used in the field to examine the tension except load cells.
Figure 11: External tendon of the approach bridge of Incheon Grand Bridge.
(a) Vibration preventing device
[figure omitted; refer to PDF]
(b) Deviation block
[figure omitted; refer to PDF]
Figure 12 and Table 9 show that existing theories show significant errors with the external tendon, which is unlike the cases in the cable stays in the Yeongdeok Bridge number 1. This is because the external tendon differs significantly in many aspects of the assumptions. The tension estimation technique using the system identification method showed increased errors from the level in Yeongdeok Bridge. Still, however, the range of errors did not exceed 5%.
Table 9: Mean and standard deviation (%) of tension estimation errors for external tendon.
Method | Mean | Standard deviation |
Taut string theory | 18.60 | 7.61 |
Linear regression method | 11.13 | 4.19 |
System identification method (this study) | 3.11 | 2.21 |
Figure 12: Tension estimation error (%) of external tendon of Incheon Grand Bridge.
[figure omitted; refer to PDF]
5.3. Extradosed Cable for Aam Bridge
Aam Bridge of Figure 13 constructed in the approach sector of the Incheon Grand Bridge. It was built as an extradosed bridge, which is similar to a cable stayed bridge and uses MS (multistrand) cables that are shielded in HDPE pipes. There is no separate grouting inside the cable. Figure 14 shows the vibration measurement set-up of an extradosed cable.
Figure 13: An overall view of Aam Bridge.
[figure omitted; refer to PDF]
Figure 14: Vibration measurement set-up.
[figure omitted; refer to PDF]
The cables used in Aam Bridge are relatively long in length, and the estimation results of their tension using the existing theories, as shown in Figure 15 and Table 10, show somewhat improved results compared to those of the system identification method. However, all methods showed tensile force estimation errors within a range of 5%. Therefore, the system identification method is thought to be applicable to the field operations if field engineers assume a ±5% error when estimating tensile force due to errors in the acceleration signal measurements, material properties, and geometrical variable errors, and other environmental errors that cannot be excluded theoretically, such as thermal influence.
Table 10: Mean and standard deviation (%) of tension estimation errors for extradosed cables.
Method | Mean | Standard deviation |
Taut string theory | 1.93 | 1.24 |
Linear regression method | 1.08 | 0.54 |
System identification method (this study) | 2.27 | 1.34 |
Figure 15: Tension estimation error (%) of Aam Bridge.
[figure omitted; refer to PDF]
5.4. The Sigma Level Calculation of the Field Application Results
The statistical information (i.e., error of estimation method) is very important to field engineers. Therefore, as shown in Figures 16, 17, and 18, we performed sigma-level calculations for three field application results based on each tensile force estimation method to verify their reliabilities and applicability. In this case, the string theory and the linear regression methods differed in terms of their error level depending on the site, which did not satisfy the requirements for regularity. Therefore, the DPMO (Defect Per Million Opportunities) method was used for a short-term sigma-level calculation. As for the system identification method, it satisfied the regularity requirement, and the Z -bench value was used to calculate the short-term sigma level. In all methods, a tensile force estimation error of 5% was set as the upper limit.
Figure 16: Process capability of field application error for the taut string theory.
[figure omitted; refer to PDF]
Figure 17: Process capability of field application error for the linear regression method.
[figure omitted; refer to PDF]
Figure 18: Process capability of field application error for the system identification method.
[figure omitted; refer to PDF]
As with Table 11, the system identification method was shown to be a better method than existing theories in terms of field applicability for external tendons of various types if the yield and short-term sigma level are compared.
Table 11: Final yield and short-term sigma level.
Method | DPMO/ [figure omitted; refer to PDF] -bench | Yield (%) | Short-term sigma level |
Taut string theory | 400,000 | 60.0 | 1.75 |
Linear regression method | 363,636 | 63.6 | 1.85 |
System identification method (this study) | 1.67 | 95.3 | 3.17 |
6. Conclusion
This study used the system identification method for estimating the tensile force of external tendons to benchmark numerical examples, laboratory test samples, and field structure to get the following conclusion.
The string theory and the linear regression method are based on theoretical closed-form equations. For this reason, they showed an allowable level of errors in terms of estimating the tensile force for the field applications with the external tendons that had similar characteristics with the assumptions used in deriving the relationship equations between the natural frequencies and tensile forces (for Yeongdeok number 1 Bridge and Aam Bridge). However, they were not applicable for field applications as the errors were too large for the external tendons with different properties from those assumed, whereas the tension estimation method using the system identification technique was applicable not only to the external tendons to which the existing theories could be applied (Yeongdeok number 1 Bridge and Aam Bridge) but also to the external tendons to which they could not be applied (approach bridge section of Incheon Grand Bridge). This is because the development method was based on the finite element model. Also, the newly developed method could use the SRSS errors between the measurements of natural frequencies and their calculated results to determine the reliability of the estimated tensile force. Therefore, the tensile force estimation method using the system identification technique could be used efficiently to estimate the tensile forces of various types of external tendons.
Acknowledgments
This research was supported by the Construction Core Technology Program funded by the Ministry of Construction & Transportation of the Korean government (Grant no. 2006-D20). The financial support is gratefully acknowledged.
Conflict of Interests
The authors declare that there is no conflict of interests regarding the publication of this paper.
[1] H. M. Irvine Cable Structures , The MIT Press, Cambridge, Mass, USA, 1981.
[2] H. Zui, T. Shinke, Y. Namita, "Practical formulas for estimation of cable tension by vibration method," Journal of Structural Engineering , vol. 122, no. 6, pp. 651-656, 1996.
[3] W.-H. P. Yen, A. B. Mehrabi, H. Tabatabai, "Evaluation of stay cable tension using a non-destructive vibration technique," in Proceedings of the 15th Structures Congress, pp. 503-507, ASCE, New York, NY, USA, April 1997.
[4] A. B. Mehrabi, H. Tabatabai, "Unified finite difference formulation for free vibration of cables," Journal of Structural Engineering , vol. 124, no. 11, pp. 1313-1322, 1998.
[5] T. Park, B. H. Kim, "Estimation of cable tension using system identification technique: I. theory," Journal of the Korean Society of Civil Engineers , vol. 25, no. 4A, pp. 661-668, 2005.
[6] T. Park, S. Moon, H. J. Joo, B. H. Kim, "Estimating tensile force of hangers in suspension bridges using frequency based SI technique: I. Theory," Journal of the Korean Society of Civil Engineers , vol. 27, no. 2, pp. 165-172, 2007.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2015 Myung-Hyun Noh et al. Myung-Hyun Noh et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
Various types of external tendons are considered to verify the applicability of tension estimation method based on the finite element model with system identification technique. The proposed method is applied to estimate the tension of benchmark numerical example, model structure, and field structure. The numerical and experimental results show that the existing methods such as taut string theory and linear regression method show large error in the estimated tension when the condition of external tendon is different with the basic assumption used during the derivation of relationship between tension and natural frequency. However, the proposed method gives reasonable results for all of the considered external tendons in this study. Furthermore, the proposed method can evaluate the accuracy of estimated tension indirectly by comparing the measured and calculated natural frequencies. Therefore, the proposed method can be effectively used for field application of various types of external tendons.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer