1. Introduction
In Newtonian fluid, flow complexity originates mostly from the nontrivial inertial effect, which is mainly induced in the macroscale condition [1]. In microfluidics, the Reynolds (Re) number of Newtonian fluid is usually a very small value, and the inertial effect is negligible. Therefore, only creeping flow is induced in the microscale Newtonian fluid [2]. For viscoelastic fluid, on the other hand, complex flow behavior can be stimulated from the polymer molecules or surfactant dispersed in the fluid [3,4,5]. In certain designed microchannel structures, the polymer molecules or surfactant can be compressed or stretched to induce significant normal stress in the fluid. As a result, various complex flows such as turbulent flow, Couette flow, or swirling flow can be obtained in viscoelastic fluid even at the micrometer scale [6,7,8,9]. Analytically, complex flow can be understood from the Navier–Stokes equation, whereby the nonlinearity of Newtonian fluid depends on the advective term in the equation, while viscoelastic fluid nonlinearity is also contributed by the rheological effects from the normal stress in the fluid [10], which can be applied for mixing [11,12] or sorting [13] in microfluidics.
In particular, the elastic instability of viscoelastic fluid in specially designed microfluidic channels has been intensively studied [14,15]. One classical geometry of the microfluidic channel is a cross-slot, which consists of two perpendicular intersecting straight channels [16,17,18]. In the cross-slot, a stagnation point can be found at the cross center when fluid is injected into both ends of one straight channel and flows out from both ends of the other straight channel. Due to the structure symmetry, the flow velocity is 0 at the stagnation point while the velocity gradient is finite. This introduces an extensional flow in the microchannel, which can stretch or compress the polymer molecule in the fluid. The normal stress is, thus, induced and leads to elastic instability of the flow when the Weissenberg (Wi) number of the fluid exceeds a critical value. Below the critical Wi number, the viscoelastic flow is steady and symmetric, behaving as a Newtonian fluid. The flow pattern becomes asymmetric as the flow rate and Wi number increase beyond a critical vale. As the Wi number further increases, the flow pattern fluctuates and becomes time-dependent. Numerically, elastic instability was studied by investigating the flow of an upper-convicted Maxwell (UCM) fluid in a cross-slot channel, and different rheological conditions were analyzed for different instability types [19]. The Oldroyd-B model and a simplified Phan–Thien–Tanner model were also established for the analysis [20,21,22]. In addition, elastic instability has been demonstrated experimentally using different types of viscoelastic fluids such as polymer solution or micellar solution [23,24]. Instability was also studied by analyzing the flow under different aspect ratios of the cross-slot geometry [19]. The cross-slot was also used as a flow-focusing device to induce purely elastic instability [25]. Other geometries, such as a T-structured channel, were proposed, and a direct transition from symmetric flow to time-dependent flow was observed in the channel [26]. Contraction–expansion microchannels were also proposed, in which the extension and relaxation of polymer molecules were observed to study the elastic instability [27].
Previous work has mainly focused on the effect of microstructure geometry and fluid properties on the flow elastic instability. In these studies, the instability was fully characterized by the Weissenberg number. Here, we experimentally demonstrate a flow direction-sensitive elastic instability even at the same Weissenberg number. This can be used to stabilize or induce elastic instability by simply altering the flow direction without changing the flow rate. Unlike previous designs, the microchannel was a symmetry-breaking geometry, consisting of a square chamber and a nozzle structure. Therefore, the flow path in one direction was not the same as that in the opposite direction. This microchannel with carefully designed asymmetry has been intensively reported to realize a rectifying property, which induces different flow pressure depending on the flow direction under the same flow rate [28,29]. The microfluidic diode and memory were then developed on the basis of this rectifying function [30,31]. Here, we observed flow direction-dependent elastic instability, with symmetric steady flow evolving into an asymmetric unsteady flow. In addition, turbulence was also observed in certain Wi number conditions in the unsteady flow.
2. Methods
The microchannel applied for obtaining non-Newtonian fluid instability was fabricated using a standard soft lithography process. A SU8-3000 photoresist (MicroChem) layer with a thickness of 50 µm was first spin-coated on a Si wafer, followed by an optical lithography process to develop the microchannel pattern. Liquid PDMS with a base and curing agent mixing ratio of 10:1 was then spin-coated on the patterned SU8 layer and heated for 4 h at 65 °C, yielding a solid layer of 50 µm thickness. The solid PDMS layer was peeled off from the Si wafer and bonded with a flat PDMS layer. The fabricated microfluidic channel is illustrated in Figure 1. The channel was composed of a square chamber and a symmetric nozzle structure. The square chamber in the microfluidic channel induces expansion and contraction of the flow, which introduces normal stress into the viscoelastic fluid. The nozzle structure is located on one side of the square chamber, which increases the localized flow resistance and confers the whole microfluidic channel with a symmetric-breaking structure. As shown in Figure 1, the width and height of the microchannel were w0 = 100 μm and h = 50 μm, respectively. The width and length of the square chamber were w1 = 300 μm and w2 = 300 μm, and the nozzle had a width of 50 μm. The channel between the left-side inlet and the nozzle structure, and the channel between the right-side inlet and the square chamber were both designed with a length of 4 mm, which was long enough for the full development of the flow. To clarify the two flow directions in the microchannel, the forward direction was defined as the direction with flow passing through the nozzle first, while the backward direction was defined as the direction with flow passing through the square chamber first, as indicated by the blue arrow and red arrow in Figure 1, respectively.
The streamline of the flow was recorded under a microscope by adding polystyrene tracking particles with a diameter of 1 µm in a concentration of 0.6 µL/mL. The flow pattern was studied at different flow rates and, therefore, different Wi numbers for the viscoelastic fluid. The Weissenberg number, defined as , describes the elasticity of the flow and qualifies the nonlinearity of the fluid, where is the characteristic length of the channel, is the flow rate in the channel, and is the relaxation time of the fluid, referring to the characteristic stretch–relax time of the polymer, which was measured as ~0.1 s for the PAM of 500 ppm. The Reynolds number is used to characterize the relationship between the inertial and viscous forces in the Newtonian fluid, expressed as , where is the density of the fluid.
3. Results and Discussion
We used polyacrylamide (PAM) with a molecular weight of 18 million for the viscoelastic fluid instability demonstration. PAM of 100, 200, 500, and 1000 ppm was measured using a rotational rheometer (Malvern, Discovery HR1) with cone-plate geometry. The cone had a diameter of 60 mm and angle of 2.006°. The complex shear modulus of the PAM solutions are shown in Figure 2. The storage modulus G′ was larger than the loss modulus G″ at the lower frequency band, confirming the elastic property of the fluid. The two curves of G′ and G″ crossed at 2, 4, 5, and 10 Hz for PAM of 100, 200, 500, and 1000 ppm. An increased crossing frequency indicates a larger elasticity of the solution with a higher ppm value. The viscosity of the fluid at different shear rates is shown in Figure 3a. The viscosity continuously decreased from ~10 Pa∙s to ~0.01 Pa∙s in the shear rate range from 0.1 s−1 to 100 s−1. For comparison, the viscosity of two typical Newtonian fluids, glycerol solution and DI water, was also measured, as shown in Figure 3b. The viscosity remained almost constant at 0.1595 and 0.0054 Pa∙s for the 80% and 50% volume concentrations of glycerol, respectively, and at 0.0008 Pa∙s for the DI water. For the subsequent fluid instability investigation, we chose PAM of 500 ppm with moderate viscosity.
The flow of the PAM solution in the nozzle–square microchannel was first investigated in low Wi number conditions. The flow rate was controlled with a syringe pump (NE-300 Just Infusion™). It was first set to Q = 100 µL/h, corresponding to Wi = 5.56. Figure 4a,b present the streamline patterns of the forward flow and backward flow in the square chamber, respectively. The streamline patterns were both symmetric and steady in the low Weissenberg condition for the forward and backward flow, indicating that no elastic instability was induced. The flow patterns for both directions were almost the same; therefore, the nozzle structure has little impact on the flow in low Wi number conditions. For both directions, the streamline expanded to the square chamber first when entering the contraction–expansion structure, and then gradually concentrated to the center with a small streamline curvature. On the other hand, at the two corners of the chamber where the fluid flowed out, the tracking particles remained static and the fluid formed a stationary regime.
Then, we increased the flow rate of PAM solution to Q = 300 µL/h, and the Wi number was increased to 16.67. The patterns recorded at three different instants are shown in Figure 5a–c. Similarly, to Figure 4a, the streamline expanded to the square chamber first when entering the contraction–expansion structure, and then gradually concentrated to the center. However, the curvatures of the streamline on the left side and the right side of the flow were no longer always the same. In addition, the stationary triangle regime (highlighted by the red dashed line) increased in size compared to Figure 4a. It can be clearly seen that the forward flow pattern became asymmetric and time-dependent. As the inertial effect is negligible at this flow rate, the instability should be purely elastic, thus stemming from the normal stress in the viscoelastic fluid. On the other hand, the backward flow at the same flow rate and Wi number, as shown in Figure 5d, remained steady and symmetric, and the flow pattern was almost the same as that in Figure 4b. The significant difference between the forward and backward flow patterns indicates that the flow elastic instability was direction-dependent in the asymmetric microchannel structure. For forward flow, it became extensional at the nozzle structure, and the normal stress increased before the fluid entered the square chamber. As a result, it was more likely to induce elastic instability. On the other hand, for backward flow, the nozzle structure increased the flow resistance of the fluid passing through the square chamber, which stabilized the flow.
As the flow rate of the PAM solution was increased to 1000 µL/h, the Wi number increased to 55.56. The instability of the forward flow became more significant, as shown in Figure 6a–c, which represent the flow pattern at different instants. In Figure 6a, the streamline was biased to the left side, and a large stationary regime formed on the right side of the square chamber. In particular, due to the large normal stress, turbulence occurred in the left-side triangle regime. In Figure 6b, the flow became symmetric and the turbulence disappeared. When the streamline become right-side-biased, as shown in Figure 6c, turbulence formed again in the right-side triangle regime. The streamlines in Figure 6a,c are almost mirror images. On the other hand, for backward flow, as shown in Figure 6d, the flow was still stabilized by the nozzle structure and remained symmetric and steady.
As the flow rate of the PAM solution was increased to 2000 µL/h, the Wi number increased to 111.11. The forward flow was still asymmetric and unsteady with turbulence on the streamline biased side, as shown in Figure 7a–c. On the other hand, as shown in Figure 7d–f, the backward flow started to become asymmetric and unsteady in this high Wi number condition. The increase in elastic instability in the backward flow was due to the normal stress now being large enough to exceed the stabilizing effect by the nozzle structure.
To quantitatively analyze the instability behavior, we measured the length between the left upper corner of the square chamber and the left edge of the forward-flowing streamline. We noted that length d = d1 (as in Figure 5a) when the streamline edge was on the left side of the chamber, and d = −d2 (as in Figure 6b) when the streamline edge was on the upper side of the chamber. The real-time change of d from 1 s to 30 s is plotted in Figure 8 for different Wi numbers. We can see obvious resonances of d for the cases Wi = 16.67 and 55.56, indicating a significant instability of the streamline. The streamline continuously oscillated with a period of ~10 s and ~20 s for Wi = 16.67 and 55.56, respectively. In addition, d was mostly above 0 for Wi = 16.67, indicating that the edge of the streamline was on the left-side edge of the square chamber. On the other hand, d fluctuated between positive and negative values for Wi = 55.56, indicating that the edge of the streamline was on the left-side edge and upper-side edge of the square chamber, respectively. When Wi = 111.11, d was a negative value because the edge of the streamline remained on the upper-side edge of the square chamber at all measured timepoints. Thus, the oscillation became less obvious.
To verify whether the above instability was elastic-related, we injected Newtonian fluid into the nozzle–square microchannel for comparison. Here, a glycerol solution of 80% volume concentration is used. The flow rate was set to Q = 2000 µL/h, corresponding to an Re number of 0.07. As shown in Figure 9a,b, the forward flow and backward flow of the glycerol solution were both symmetric and steady, and both flow patterns were almost the same. This verifies that the asymmetric flow pattern, the unsteady streamline, and the flow direction-dependent instability of the PAM solution were due to the fluid elastic property.
To further explain the effect of the nozzle structure, we prepared a microchannel without a nozzle structure using only the same square chamber. The microchannel structure was symmetric; thus, we only investigated the PAM flow along one direction. Figure 10a–c show the flow pattern of the PAM solution at different instants at Q = 300 µL/h and Wi = 16.67. The flow remained in a symmetric static state, and there was no flow instability. Figure 10d–f show the flow pattern of the PAM solution at different instants at Q = 1000 µL/h and Wi = 55.56. The flow became asymmetric and unsteady due to the increased normal stress when the flow entered the expansion square chamber and formed an extensional flow. As the flow rate Q increased to 2000 µL/h and Wi = 111.11, the asymmetry and instability of the flow pattern became more obvious, as presented by the three different patterns shown in Figure 10g–i.
On the basis of the above analysis, the instability of the viscoelastic flow in the asymmetric nozzle–square microchannel and in the symmetric square microchannel is summarized in Figure 11. The critical Wi number for the flow instability was not only different for the square–nozzle microchannel and the square-only microchannel, but also different for the forward-directed flow and the backward-directed flow in the same nozzle–square microchannel. The critical Wi number for the forward-directed flow in the nozzle–square microchannel was the smallest, indicating that it is easiest to induce elastic instability in such a flow condition. This is because the polymers in the viscoelastic fluid were stretched by the nozzle structure before entering the square structure, facilitating the induction of normal stress in the subsequent extensional flow. On the other hand, the critical Wi number for the backward-directed flow in the nozzle–square microchannel was the largest, indicating that it is hardest to induce elastic instability in such a flow condition. This is because the nozzle structure increased the flow resistance before the flow entered the square structure, which stabilized the flow.
4. Conclusions
In summary, we studied the viscoelastic fluid instability in an asymmetric nozzle–square microchannel. The instability was demonstrated to be purely elastic and dependent on the flow Weissenberg number. Beyond a certain Wi number, the flow pattern was converted from a symmetric steady state to an asymmetric unsteady state. The critical Wi number was demonstrated to be different for the two flow directions in the same nozzle–square microchannel. In other words, the flow instability was flow direction-dependent even at the same Wi number and in the same microchannel structure. This flow direction-dependent instability can not only be applied for fluidic rectifier applications, but also be used to stabilize viscoelastic flow in high-flow-rate conditions for mass transportation.
Conceptualization, W.Z. and M.Z.; methodology, Z.W. and J.L.; validation, W.C. and Y.H.; formal analysis, W.Z. and M.Z.; investigation, W.Z. and S.L.; resources, W.Z.; data curation, M.Z. and Z.W.; writing—original draft preparation, W.Z.; writing—review and editing, W.Z.; visualization, M.Z.; supervision, W.Z.; funding acquisition, W.Z. All authors have read and agreed to the published version of the manuscript.
The research was funded by the National Natural Science Foundation of China (Grant No. 61905046), the China Postdoctoral Science Foundation (Grant No. 2020M683044), the Provincial Key Laboratory of Information Photonics Technology (Guangdong University of Technology, Grant No. GKPT20-08), the Science and Technology Projects in Guangzhou (Grant No. 202102010446), and the National College Student Innovation and Entrepreneurship Training Program of Guangzhou University (Grant No. 202111078049).
Raw data presented in this study are available on request from the corresponding author.
The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Figure 1. Schematic of microchannel consisting of a square chamber and nozzle structure.
Figure 2. Complex shear modulus of the PAM solutions of (a) 100, (b) 200, (c) 500, and (d) 1000 ppm.
Figure 3. (a) Viscosity of non-Newtonian PAM solution and (b) Newtonian solutions.
Figure 4. Viscoelastic flow pattern in the square chamber for flow along (a) the forward direction and (b) the backward direction at Wi = 5.56.
Figure 5. Viscoelastic flow pattern in the square chamber for flows along the forward direction at (a–c) three different instants, and (d) backward direction at Wi = 16.67.
Figure 6. Viscoelastic flow pattern in the square chamber for flows along the forward direction at (a–c) three different instants, and (d) backward direction at Wi = 55.56.
Figure 7. Viscoelastic flow pattern in the square chamber for (a–c) flows along the forward direction at three different instants, and (d–f) flows along the backward direction at three different instants at Wi = 111.11.
Figure 8. The edge length of the forward-flowing streamline on the left side of the flow.
Figure 9. Flow pattern of the glycerol solution in (a) forward direction and (b) backward direction at Q = 2000 µL/h.
Figure 10. The PAM flow pattern in the symmetric square-only microchannel at three different instants (a–c) when Wi = 16.67, (d–f) when Wi = 55.56, and (g–i) when Wi = 111.11.
Figure 11. Critical Weissenberg number phase diagram for the two flow directions in the nozzle–square microchannel and the flow in the square-only microchannel.
References
1. Sahu, K.C.; Valluri, P.; Spelt, P.D.; Matar, O.K. Linear instability of pressure-driven channel flow of a Newtonian and a Herschel-Bulkley fluid. Phys. Fluids; 2007; 19, 122101. [DOI: https://dx.doi.org/10.1063/1.2814385]
2. Tian, F.; Zhang, W.; Cai, L.; Li, S.; Hu, G.; Cong, Y.; Liu, C.; Li, T.; Sun, J. Microfluidic co-flow of Newtonian and viscoelastic fluids for high-resolution separation of microparticles. Lab Chip; 2017; 17, pp. 3078-3085. [DOI: https://dx.doi.org/10.1039/C7LC00671C] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28805872]
3. Miller, E.; Cooper-White, J. The effects of chain conformation in the microfluidic entry flow of polymer-surfactant systems. J. Non-Newton. Fluid Mech.; 2009; 160, pp. 22-30. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2009.02.009]
4. Li, X.B.; Li, F.C.; Cai, W.H.; Zhang, H.N.; Yang, J.C. Very-low-Re chaotic motions of viscoelastic fluid and its unique applications in microfluidic devices: A review. Exp. Therm. Fluid Sci.; 2012; 39, pp. 1-16. [DOI: https://dx.doi.org/10.1016/j.expthermflusci.2011.12.014]
5. Zhang, M.; Zhang, W.; Wu, Z.; Shen, Y.; Wu, H.; Cheng, J.; Zhang, H.; Li, F.; Cai, W. Modulation of viscoelastic fluid response to external body force. Sci. Rep.; 2019; 9, 9402. [DOI: https://dx.doi.org/10.1038/s41598-019-45612-2] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31253813]
6. Sousa, P.C.; Pinho, F.T.; Alves, M.A. Purely-elastic flow instabilities and elastic turbulence in microfluidic cross-slot devices. Soft Matter; 2018; 14, pp. 1344-1354. [DOI: https://dx.doi.org/10.1039/C7SM01106G]
7. Groisman, A.; Steinberg, V. Elastic turbulence in curvilinear flows of polymer solutions. New J. Phys.; 2004; 6, 29. [DOI: https://dx.doi.org/10.1088/1367-2630/6/1/029]
8. Groisman, A.; Steinberg, V. Mechanism of elastic instability in Couette flow of polymer solutions: Experiment. Phys. Fluids; 1998; 10, pp. 2451-2463. [DOI: https://dx.doi.org/10.1063/1.869764]
9. Larson, R.G.; Shaqfeh, E.S.; Muller, S.J. A purely elastic instability in Taylor–Couette flow. J. Fluid Mech.; 2006; 218, pp. 573-600. [DOI: https://dx.doi.org/10.1017/S0022112090001124]
10. Yuan, C.; Zhang, H.N.; Li, Y.K.; Li, X.B.; Wu, J.; Li, F.C. Nonlinear effects of viscoelastic fluid flows and applications in microfluidics: A review. Proc. Inst. Mech. Eng. Part C-J. Mech. Eng. Sci.; 2020; 234, pp. 4390-4414. [DOI: https://dx.doi.org/10.1177/0954406220922863]
11. Zhang, M.; Zhang, W.; Wu, Z.; Shen, Y.; Chen, Y.; Lan, C.; Li, F.; Cai, W. Comparison of Micro-Mixing in Time Pulsed Newtonian Fluid and Viscoelastic Fluid. Micromachines; 2019; 10, 262. [DOI: https://dx.doi.org/10.3390/mi10040262]
12. Zhang, M.; Cui, Y.; Cai, W.; Wu, Z.; Li, Y.; Li, F.; Zhang, W. High Mixing Efficiency by Modulating Inlet Frequency of Viscoelastic Fluid in Simplified Pore Structure. Processes; 2018; 6, 210. [DOI: https://dx.doi.org/10.3390/pr6110210]
13. Nam, J.; Lim, H.; Kim, D.; Jung, H.; Shin, S. Continuous separation of microparticles in a microfluidic channel via the elasto-inertial effect of non-Newtonian fluid. Lab Chip; 2012; 12, pp. 1347-1354. [DOI: https://dx.doi.org/10.1039/c2lc21304d] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/22334376]
14. Galindo-Rosales, F.J.; Campo-Deano, L.; Sousa, P.C.; Ribeiro, V.M.; Oliveira, M.S.; Alves, M.A.; Pinho, F.T. Viscoelastic instabilities in micro-scale flows. Exp. Therm. Fluid Sci.; 2014; 59, pp. 128-139. [DOI: https://dx.doi.org/10.1016/j.expthermflusci.2014.03.004]
15. Pan, L.; Morozov, A.; Wagner, C.; Arratia, P.E. Nonlinear Elastic Instability in Channel Flows at Low Reynolds Numbers. Phys. Rev. Lett.; 2013; 110, 174502. [DOI: https://dx.doi.org/10.1103/PhysRevLett.110.174502]
16. Davoodi, M.; Houston, G.; Downie, J.; Oliveira, M.S.; Poole, R.J. Stabilization of purely elastic instabilities in cross-slot geometries. J. Fluid Mech.; 2021; 922, A12. [DOI: https://dx.doi.org/10.1017/jfm.2021.473]
17. Sousa, P.C.; Pinho, F.T.; Oliveira, M.S.; Alves, M.A. Purely elastic flow instabilities in microscale cross-slot devices. Soft Matter; 2015; 11, pp. 8856-8862. [DOI: https://dx.doi.org/10.1039/C5SM01298H] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/26395149]
18. Poole, R.J.; Alves, M.A.; Oliveira, P.J. Purely elastic flow asymmetries. Phys. Rev. Lett.; 2007; 99, 164503. [DOI: https://dx.doi.org/10.1103/PhysRevLett.99.164503]
19. Cruz, F.A.; Poole, R.J.; Afonso, A.M.; Pinho, F.T.; Oliveira, P.J.; Alves, M.A. Influence of channel aspect ratio on the onset of purely-elastic flow instabilities in three-dimensional planar cross-slots. J. Non-Newton. Fluid Mech.; 2016; 227, pp. 65-79. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2015.11.008]
20. Canossi, D.O.; Mompean, G.; Berti, S. Elastic turbulence in two-dimensional cross-slot viscoelastic flows. Epl; 2020; 129, 7. [DOI: https://dx.doi.org/10.1209/0295-5075/129/24002]
21. Zografos, K.; Burshtein, N.; Shen, A.Q.; Haward, S.J.; Poole, R.J. Elastic modifications of an inertial instability in a 3D cross-slot. J. Non-Newton. Fluid Mech.; 2018; 262, pp. 12-24. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2018.02.002]
22. Afonso, A.M.; Pinho, F.T.; Alves, M.A. Electro-osmosis of viscoelastic fluids and prediction of electro-elastic flow instabilities in a cross slot using a finite-volume method. J. Non-Newton. Fluid Mech.; 2012; 179, pp. 55-68. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2012.05.004]
23. Zhao, Y.; Shen, A.Q.; Haward, S.J. Flow of wormlike micellar solutions around confined microfluidic cylinders. Soft Matter; 2016; 12, pp. 8666-8681. [DOI: https://dx.doi.org/10.1039/C6SM01597B] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/27722471]
24. Haward, S.J.; McKinley, G.H.; Shen, A.Q. Elastic instabilities in planar elongational flow of monodisperse polymer solutions. Sci. Rep.; 2016; 6, 33029. [DOI: https://dx.doi.org/10.1038/srep33029] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/27616181]
25. Ballesta, P.; Alves, M.A. Purely elastic instabilities in a microfluidic flow focusing device. Phys. Rev. Fluids; 2017; 2, 053301. [DOI: https://dx.doi.org/10.1103/PhysRevFluids.2.053301]
26. Soulages, J.; Oliveira, M.S.; Sousa, P.C.; Alves, M.A.; McKinley, G.H. Investigating the stability of viscoelastic stagnation flows in T-shaped microchannels. J. Non-Newton. Fluid Mech.; 2009; 163, pp. 9-24. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2009.06.002]
27. Tai, J.; Lim, C.P.; Lam, Y.C. Visualization of polymer relaxation in viscoelastic turbulent microchannel flow. Sci. Rep.; 2015; 5, 16633. [DOI: https://dx.doi.org/10.1038/srep16633]
28. Sousa, P.C.; Pinho, F.T.; Oliveira, M.S.; Alves, M.A. Efficient microfluidic rectifiers for viscoelastic fluid flow. J. Non-Newton. Fluid Mech.; 2010; 165, pp. 652-671. [DOI: https://dx.doi.org/10.1016/j.jnnfm.2010.03.005]
29. Sousa, P.C.; Pinho, F.T.; Oliveira, M.S.; Alves, M.A. High performance microfluidic rectifiers for viscoelastic fluid flow. Rsc Adv.; 2012; 2, pp. 920-929. [DOI: https://dx.doi.org/10.1039/C1RA00803J]
30. Adams, M.L.; Johnston, M.L.; Scherer, A.; Quake, S.R. Polydimethylsiloxane based microfluidic diode. J. Micromech. Microeng.; 2005; 15, pp. 1517-1521. [DOI: https://dx.doi.org/10.1088/0960-1317/15/8/020]
31. Groisman, A.; Enzelberger, M.; Quake, S.R. Microfluidic Memory and Control Devices. Science; 2003; 300, 955. [DOI: https://dx.doi.org/10.1126/science.1083694] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/12738857]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
This paper reports flow direction-dependent elastic instability in a symmetry-breaking microchannel. The microchannel consisted of a square chamber and a nozzle structure. A viscoelastic polyacrylamide solution was used for the instability demonstration. The instability was realized as the viscoelastic flow became asymmetric and unsteady in the microchannel when the flow exceeded a critical Weissenberg number. The critical Weissenberg number was found to be different for the forward-directed flow and the backward-directed flow in the microchannel.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 College of Physical and Material Engineering, Guangzhou University, Guangzhou 510006, China;
2 Precision Medicine Institute, the First Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, Guangzhou 510080, China;
3 School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore;




