Introduction
Carbonaceous aerosols are one of the major components of fine particulate matter (PM in urbanized areas as a result of intense anthropogenic emissions. Carbonaceous aerosols consist of three categories: organic carbon (OC), elemental carbon (EC), and carbonate carbon (CC). OC can be either primary or secondary in origin, but EC is exclusively from primary emission. CC is only abundant in regions affected by mineral dust outflow and is negligible in other areas. OC and EC not only contribute to the overall PM load, but these components have specific public health concerns because of their interactions with the human body (Dou et al., 2015; Shi et al., 2015), and they significantly contribute to visibility degradation (Malm et al., 1994) and climate forcing (Bond et al., 2011).
Differentiating OC and EC is still challenging due to their complex chemical structure and optical properties. The most widely used technique to separate OC and EC is thermal optical analysis (TOA), which involves volatilizing the OC from a substrate while increasing the temperature by steps in an inert pure-helium atmosphere followed by combusting EC component in an oxygenated He atmosphere. A correction for charred OC (pyrolysis carbon, PC) in the inert stage relies on continuous monitoring of laser transmittance or reflectance of the filter. However, the separation of OC and EC in TOA is operationally defined due to the lack of widely accepted reference materials for calibration. A variety of TOA protocols are used by different research groups and monitoring networks (Watson et al., 2005). Among the TOA protocols, National Institute for Occupational Safety and Health (NIOSH; Birch and Cary, 1996) and Interagency Monitoring of Protected Visual Environment (IMPROVE; Chow et al., 1993) are most widely applied, which differ in their temperature ramping, step duration, and optical correction schemes (Table S1 in the Supplement). It is worth noting that the NIOSH protocol only outlines the necessary analysis principle for operation without specifying detailed technical parameters. Therefore, a number of NIOSH-type protocols exist in the literature (Watson et al., 2005), with the peak inert mode temperatures (PIMTs) varied from 850 to 940 C.
Previous studies suggest that total carbon (TC), which is the sum of OC and EC, agrees very well (Chow et al., 2001) between the two protocols, but measured EC differs by a factor of 2–10, depending on the source and aging of the samples (Chow et al., 2001; Cheng et al., 2014). The EC discrepancy between NIOSH and IMPROVE mainly arises from the temperature ramping regime and the charring correction. The PIMT in NIOSH (870 C) is much higher than in IMPROVE (550 C). Thus, NIOSH may be subject to premature EC evolution (i.e., underestimation of EC), but IMPROVE may overestimate EC following incomplete OC evolution in the inert atmosphere (Piazzalunga et al., 2011). Since the optimal PIMT could vary between samples, a universal PIMT does not exist to avoid both of these biases (Subramanian et al., 2006). It should be noted that the residence time is different from sample to sample as the IMPROVE protocol only advances temperature to the next step until a well-defined carbon peak has evolved. In addition, IMPROVE uses a laser reflectance signal to perform the charring correction (TOR, thermal optical reflectance), while NIOSH adopts a laser transmittance for charring correction (TOT, thermal optical transmittance). Correction by reflectance only accounts for charring at the filter surface (Chow et al., 2004), while the transmittance correction considers charring throughout the filter, leading to a discrepancy in reporting PC.
The Pearl River Delta (PRD) is one of the most developed areas in China and home to the biggest city clusters in the world (World Bank, 2015). Air pollution issues have arisen from the economic bloom since the 1980s and pose a threat to public health (Tie et al., 2009). Although it is one of the biggest cites in the PRD, Hong Kong lacked an air quality objective regarding PM until January 2014. To better understand the variability of chemical compositions of PM, the Hong Kong Environmental Protection Department of the Hong Kong Special Administration Region (HKEPD) has established a regular PM speciation monitoring program since 2011, including six monitoring sites, covering both suburban and urban conditions. The samples collected in the 3-year period 2011–2013 were analyzed by the Environmental Central Facility at the Hong Kong University of Science and Technology. These samples have been analyzed by both NIOSH TOT and IMPROVE TOR protocols, providing a unique opportunity to explore the OC and EC determination dependency on analysis protocols, which is the focus of this study. This study aims to answer the following questions: (1) what is the magnitude of the EC disagreement between the two protocols for Hong Kong samples? (2) What are the contributing factors, and how do they affect the EC discrepancy? (3) Is it feasible to perform OC and EC data inter-protocol conversion? (4) If yes, can the results be further used for secondary organic carbon (SOC) estimation?
Methods
Sample description
One 24 h PM sample (from midnight to midnight) was programmed and collected every six days from January 2011 to December 2013 at six air quality monitoring sites (AQMS) in Hong Kong. The monitoring stations include Mong Kok (MK) just beside a busy road, Central/Western (CW), Tsuen Wan (TW), Tung Chung (TC) and Yuen Long (YL) at several meters above ground in urban areas in Hong Kong, and Clear Water Bay (WB) in a suburban area, as shown in Fig. S1 in the Supplement. Partisol samplers (Rupprecht & Patashnick (now Thermo Fisher Scientific), Model 2025, Albany, NY) equipped with a Very Sharp Cut Cyclone (VSCC, BGI, Waltham, MA, USA) and operating at a flow rate of 16.7 L min were deployed at each AQMS. Two types of filter substrate were used: quartz filter (Pall, 47 mm 2500-QAT-UP-47, Ann Arbor, MI, USA) and Teflon filter (Whatman, PTFE, 46.2 mm with a support ring, Clifton, NJ, USA). Sample filters were retrieved within 24 h and stored in Petri dishes sealed with parafilm under freezing temperatures.
Thermograph of typical thermal optical analysis (sample CW20130118) using a Sunset carbon analyzer. (a) NIOSH protocol; (b) IMPROVE protocol (FID: flame ionization detector signal; PC: pyrolysis carbon; AEC: apparent EC, which is the sum of all the EC fractions before correcting for PC; temperature: oven temperature during analysis; Laser T: laser transmittance signal; Laser R: laser reflectance signal; Cal peak: calibration peak at the end of each analysis).
[Figure omitted. See PDF]
Sample analysis
Chemical analysis methods were described in detail by Huang et al. (2014), so only a brief description is given here. Teflon filters were first used for gravimetric analysis for PM mass concentrations using a microbalance (Sartorius, MC-5, Göttingen, Germany) in a temperature- and relative-humidity-controlled room, and then were used for elemental analysis (for more than 40 elements with atomic number ranging from 11 to 92) with an X-ray fluorescence (XRF) spectrometer (PANalytical, Epsilon 5, Almelo, the Netherlands). Quartz filters were analyzed by ion chromatography (Dionex, ICS-1000, Sunnyvale, CA, USA) and by TOA using a Sunset Laboratory analyzer (Tigard, OR, USA). All the OCEC samples were analyzed on the same Sunset analyzer using both NIOSH and IMPROVE protocols. Detailed temperature programs of the two protocols are shown in Table S1, and example analysis thermographs are shown in Fig. 1. The carbon analyzer is capable of performing both laser transmittance and reflectance charring corrections; thus both TOT and TOR results can be obtained for each protocol temperature program. As a result, four sets of analysis data are obtained and used for investigation of OC and EC determination dependency on analysis protocols in this study. The four sets of data are denoted as NIOSH TOT, NIOSH TOR, IMPROVE TOT, and IMPROVE TOR, with NIOSH and IMPROVE representing their respective temperature program and TOT and TOR representing the mean of charring correction based on laser transmittance and reflectance, respectively. It should be noted that NIOSH TOT and IMPROVE TOR data represent data by the two protocols, while the other two sets of data are usually not reported in EC and OC analysis. The concentrations of water-soluble organic carbon (WSOC) and three sugar compounds (levoglucosan, mannosan, and galactosan) were available for 2013 WB samples from a separate project. WSOC concentrations were measured by a TOC analyzer (Shimadzu TOC-V, Japan) (Kuang et al., 2015). The sugars were analyzed by high-performance anion-exchange chromatography (HPAEC) with a pulsed amperometric detection (PAD) method (Engling et al., 2006).
Three-year distributions of OC and EC concentrations by IMPROVE TOR and NIOSH TOT protocols for six sites in Hong Kong. The symbols in the boxplots represent the average (open circles), median (interior lines), 75th and the 25th percentile (box boundaries), and 95th and 5th percentile (whiskers).
[Figure omitted. See PDF]
Quality assurance/quality control of OCEC data
Since OC and EC are operationally defined and lack reference materials, external calibration is only performed for TC on a biweekly basis using sucrose solutions (Wu et al., 2012). Duplication analysis covering 14 % of the total samples was conducted for quality control purposes. TC by the two protocols (NIOSH and IMPROVE) agrees very well as evidenced by the unity regression slope (Fig. S2a, slope 0.99, ) and sharp frequency distribution of NIOSH TC / IMPROVE TC ratios (Fig. S2b). Nevertheless, a small number of extreme data remain. The following criteria are used during the data processing to screen out the suspicious data: 0.1 OC EC 40; 0.5 TC TC 2. After screening, a total of 1398 OCEC data points are used in this study.
Ambient mean concentrations (g m) of OC and EC for six sites in Hong Kong by IMPROVE TOR and NIOSH TOT protocols.
Site | Analysis | Chow et | Chow et | Chow et | Current study | ||||
---|---|---|---|---|---|---|---|---|---|
protocol | al. (2002) | al. (2006) | al. (2010) | ||||||
2001 | 2005 | 2009 | 2011 | 2012 | 2013 | 3-year average | |||
(Mean one standard deviation) | |||||||||
MK | IMPROVE | OC | 16.64 | 11.17 | 6.26 | 8.09 3.67 | 6.94 2.55 | 6.92 3.36 | 7.33 3.28 |
TOR | EC | 20.29 | 14.11 | 10.66 | 8.48 2.08 | 9.21 2.74 | 9.42 1.89 | 9.03 2.27 | |
NIOSH | OC | 11.36 4.26 | 10.24 3.94 | 10.51 4.63 | 10.72 4.3 | ||||
TOT | EC | 4.86 1.47 | 5.53 1.42 | 5.35 1.78 | 5.24 1.59 | ||||
TW | IMPROVE | OC | 8.69 | 6.93 | 4.38 | 5.44 3.35 | 4.5 2.4 | 4.86 3.47 | 4.94 3.14 |
TOR | EC | 5.37 | 6.25 | 3.76 | 4.24 1.81 | 3.62 1.99 | 4.01 1.71 | 3.97 1.84 | |
NIOSH | OC | 7.37 4.05 | 6.1 3.33 | 6.79 4.46 | 6.77 4.01 | ||||
TOT | EC | 1.95 0.93 | 1.76 0.91 | 1.91 0.87 | 1.88 0.9 | ||||
YL | TOR OC | OC | 7.23 | 4.83 | 5.62 3.56 | 4.77 3.02 | 4.92 4.05 | 5.16 3.63 | |
TOR EC | EC | 6.19 | 3.48 | 4.56 2.48 | 3.69 1.8 | 3.92 1.87 | 4.08 2.1 | ||
TOT OC | OC | 7.92 4.69 | 6.33 3.94 | 6.88 4.92 | 7.12 4.62 | ||||
TOT EC | EC | 1.89 0.9 | 1.79 0.91 | 1.95 1.12 | 1.88 0.98 | ||||
CW | IMPROVE | OC | 4.92 2.89 | 4.12 2.64 | 4.37 3.33 | 4.48 2.98 | |||
TOR | EC | 3.71 1.75 | 3.24 1.94 | 3.48 1.69 | 3.48 1.79 | ||||
NIOSH | OC | 6.55 3.55 | 5.55 3.27 | 6.2 4.02 | 6.12 3.64 | ||||
TOT | EC | 1.63 0.82 | 1.54 1.03 | 1.54 0.95 | 1.57 0.93 | ||||
TC | IMPROVE | OC | 5.13 3.69 | 4.17 2.68 | 4.27 4.23 | 4.53 3.63 | |||
TOR | EC | 3.65 2.3 | 3.1 1.71 | 3.37 2.14 | 3.38 2.08 | ||||
NIOSH | OC | 6.88 4.74 | 5.48 3.37 | 6.03 5.39 | 6.15 4.63 | ||||
TOT | EC | 1.53 0.91 | 1.55 0.87 | 1.46 0.91 | 1.51 0.89 | ||||
WB | IMPROVE | OC | 3.91 2.62 | 3.07 2 | 3.37 3.13 | 3.46 2.65 | |||
TOR | EC | 2.43 1.42 | 1.81 1.2 | 1.96 1.39 | 2.08 1.37 | ||||
NIOSH | OC | 5.07 3.33 | 3.91 2.53 | 4.62 3.93 | 4.55 3.36 | ||||
TOT | EC | 0.86 0.5 | 0.72 0.44 | 0.67 0.58 | 0.75 0.52 |
November 2000–October 2001; studies using DRI2001 carbon analyzer.
Results and discussion
Ambient PM OC and EC concentrations
The 3-year distribution of OC and EC concentrations is shown in Fig. 2, where a clear spatial gradient can be seen from the roadside site to the urban sites and suburban site. OC and EC levels at the MK roadside site are a factor of 2 higher for both protocols compared to the urban sites. Annual average concentrations and standard deviations for the five sites are listed in Table 1. Compared to samples collected at the MK and TW sites in November 2000–December 2001 (Chow et al., 2002), both OC and EC 3-year annual average concentrations observed in this study are lower by a factor of 1.4–2.3. At the TW site, TOR OC decreased from 8.69 to g m and TOR EC decreased from 5.37 to g m. The reduction is more pronounced at the MK roadside site, where TOR OC decreased from 16.64 to g m and TOR EC decreased from 20.29 to g m (Chow et al., 2002).
Comparison of different carbon fractions. (a) Relationship of IMPROVE apparent EC (AEC, sum of EC1 to EC3 and the sum of NIOSH apparent EC (AEC, sum of EC1 to EC6 plus OC4, (b) relationship of EC ( axis) and EC ( axis), and (c) relationship of EC ( axis) and the sum of EC and OC4 ( axis). WODR stands for weighed orthogonal distance regression.
[Figure omitted. See PDF]
NIOSH and IMPROVE comparison for OC and EC determination
The data discussed in this section use the unit of g cm because the inter-protocol comparison focuses on the analytical aspect of OC EC analysis, which is more associated with filter loading than air concentration. For data analysis involving linear regression, ordinary least-squares (OLS) regression is not suitable due to its error-free assumption in independent variables, which is unrealistic for OCEC data (Saylor et al., 2006). Weighted orthogonal distance regression (WODR) is employed in this study to account for the comparable degrees of uncertainty in both and (Boggs et al., 1989). As mentioned earlier, the difference in the peak inert mode temperature for IMPROVE (550 C) and NIOSH (870 C) is an important distinguishing factor between the two protocols. The carbon fraction evolved corresponding to the 870 C step is classified as OC4 in the NIOSH protocol, while in IMPROVE this fraction is evolved as part of apparent EC (AEC), which is the sum of all the EC fractions before correcting for charred OC. Chow et al. (2001) found NIOSH OC4 can explain most of the EC difference in US samples between the two protocols, and this relationship has been further defined in a PRD study by our group (Eq. 1), where IMPROVE AEC is found to be equivalent to the sum of NIOSH OC4 and NIOSH AEC (Wu et al., 2012).
HK samples from the current study also confirm this relationship as shown in Fig. 3a (Slope 0.99). It should be noted that, due to the much longer step durations in the IMPROVE protocol, carbon evolved beyond 550 C in IMPROVE protocol does not simply map to OC evolved beyond the same temperature point in the NIOSH protocol (i.e., temperature step beyond 550 C, which includes part of OC3 and OC4).
The reported IMPROVE TOR EC is the sum of carbon fractions evolved in the He–O stage (AEC minus PC as measured by laser reflectance. Combining Eqs. (1) and (2), the IMPROVE TOR EC can be defined as Likewise, the reported NIOSH TOT EC is the sum of carbon fractions evolved in the He–O stage (AEC minus pyrolysis carbon by laser transmittance.
As shown in Fig. 3b, the linear regression slope (2.05) of the scatterplot represents the average discrepancy between EC ( axis) and EC ( axis). As embodied in Eqs. (3) and (4), the EC discrepancy can be attributed to two factors: OC4 (thermal effect) and the difference in PC (optical method effect). Thermal effect refers to inter-protocol EC difference caused by temperature step difference. The optical method effect is the inter-protocol EC difference introduced by the PC difference between transmittance and reflectance charring correction. By adding OC4 to the axis (Fig. 3c), the effect of OC4 between (EC and (OC4 EC is minimized as embodied in Eqs. (3) and (5), where the slope (1.18) primarily represents the optical method effect caused by the PC difference (PC vs. PC.
EC-to-EC discrepancy dependency on TOT/TOR charring correction. (a) EC EC vs. PC PC ratio–ratio plot for summer and fall. (b) EC EC vs. PC PC ratio–ratio plot for spring and winter. (c) EC EC vs. PC PC ratio–ratio plot for spring and winter.
[Figure omitted. See PDF]
The difference between the slopes in Fig. 3b (slope 2.05) and Fig. 3c (slope 1.18) indicates the contribution of the thermal effect to the EC discrepancy. By examining the relative differences from unity in the two slopes (i.e., ), it is estimated that 82.86 % of the EC difference by the two protocols in HK samples is attributed to the thermal effect (OC4, and the rest (17.14 %) is due to the PC monitoring, arising from different optical methods used for the charring correction (laser transmittance or reflectance). The reduced in Fig. 3b and c compared to Fig. 3a suggest the scatter of data points is due to the optical method effect (PC). The relative contribution of the two factors in the HK samples exhibits a seasonal dependency as shown in Fig. S3. In summer and fall, the optical method effect accounts for 12 % of the EC discrepancy, while in winter and spring the optical method effect contribution is 35 %. This is in part dictated by a lower proportion of OC4 fraction in these two seasons as shown in Fig. S4, leading to an attenuated thermal effect.
It is also found that the optical method effect described above exhibits a dependency on the temperature ramping step. However, PC cannot be compared directly between the two protocols because they evolve under different temperature regimes; thus the PC difference of using the TOR or TOT signal within the protocols is compared as shown in Fig. 4. It is found that the ratio of EC EC shows a dependency on PC PC ( 0.12–0.41), and the degree of correlation varies by season (Fig. 4a and b). This result agrees well with the higher optical method effect contribution during spring and winter shown in Fig. S3 and discussed above. In contrast, EC EC is insensitive to PC PC () as shown in Fig. 4c. This selective dependency suggests the optical method effect contribution to EC dependency is distinctly sensitive to the degree of charring formed during the OC4 stage. Since PC contains char formed in the OC4 stage while PC does not, OC4 is the major difference between potential sources of PC and PC difference.
EC-to-EC discrepancy dependency on K EC ratio (biomass burning effect). (a) EC EC vs. K EC ratio–ratio plot. (b) EC (EC OC4 vs. K EC ratio–ratio plot.
[Figure omitted. See PDF]
Effect of biomass burning on OC and EC determination between IMPROVE and NIOSH
Other potential factors affecting EC discrepancy were also examined. Cheng et al. (2011a) found in Beijing samples that biomass burning can influence the EC discrepancy. Here we use a normalized abundance of K as an indicator to examine the impact of biomass burning on the EC discrepancy. Figure S5a is the same as Fig. 3b but color coded with the K EC ratio to reflect the influence from biomass burning. It reveals a pattern associated with the EC-to-EC ratio. To verify this relationship, regressions on the lowest and highest 10 % of K EC ratios are shown in Fig. S6b and S6c, respectively. The data from the highest 10 % of K EC ratios have a significantly higher regression slope (slope 3.19, Fig. S5c) than the data from the lowest 10 % of K EC ratios (slope 1.48, Fig. S5b), implying the EC discrepancy depends on the K EC ratio. To further distinguish whether the K EC effect is associated with OC4 (thermal effect) or the difference in PC (optical method effect), OC4 is added to the axis as shown in Fig. S5d–f. By adding OC4 to the axis, any discrepancy between and can be attributed to the optical method effect alone. The slopes of samples from the highest 10 % of K EC ratios (1.20, Fig. S5e) and samples from the lowest 10 % of K EC ratios (1.27, Fig. S5f) are very close to the slope using all samples (1.23, Fig. S5d), implying that the optical method effect is not sensitive to the K EC ratio. Consequently, the EC discrepancy dependence on the K EC ratio is very likely associated with OC4 (thermal effect). Since the intercepts in Fig. S5 are relatively small and their slopes can be represented by ratios, we use ratio–ratio plots to verify the relationship of K EC to OC4. As shown in Fig. 5a, when the K EC ratio goes up, a larger EC discrepancy is observed; while adding OC4 to the axis (offsetting the contribution from OC4 as shown in Fig. 5b, this relationship no longer holds. The OC4 fraction, as represented by the relative abundance of OC4 in samples (OC4 TC), exhibits a dependency on the K EC ratio as illustrated in the histograms of Fig. S6. An independent test (Table S2) was performed, finding the average OC4 TC ratio of samples from the highest 10 % of K EC ratios (0.27, Fig. S6c) is significantly higher () than the average OC4 TC ratio of samples from the lowest 10 % of K EC ratios, which reveals that the OC4 fraction and K EC ratio are positively correlated. As discussed before, the OC4 fraction can affect the EC discrepancy, which is the reason that biomass burning can influence the EC discrepancy.
Effect of metal oxides on OC and EC determination between IMPROVE and NIOSH
A suite of laboratory studies have revealed the presence of metal oxides in aerosol samples can alter the EC OC ratio, by either lowing the EC oxidation temperature or enhancing OC charring (Murphy et al., 1981; Wang et al., 2010; Bladt et al., 2014). As a result, the distribution of carbon fractions is impacted during the analysis, affecting the inter-protocol EC discrepancy. As shown in Figs. 6a and S7, the EC discrepancy positively correlates with normalized Fe abundance (Fe EC ratio), suggesting that a higher fraction of metal oxide can increase the EC divergence across the two protocols. If OC4 is added to cancel out the discrepancy contribution from the thermal effect (Figs. 6b and S7), the discrepancy due to the optical method effect alone shows no dependency on Fe abundance. Similar dependency is also found in other metal oxides like Al as shown in Fig. S8. These results imply that metal-oxide-induced EC divergence is mainly associated with the OC4 fraction.
EC-to-EC discrepancy dependency on Fe EC ratio (metal oxide effect). (a) EC EC vs. Fe EC ratio–ratio plot. (b) EC (EC OC4 vs. Fe EC ratio–ratio plot.
[Figure omitted. See PDF]
Comparison of IMPROVE TOR EC reconstruction approaches for Hong Kong samples
Description of two reconstruction methods
It is of great interest to determine the best estimation for EC when only NIOSH TOT analysis is available. This study provides an opportunity to examine different empirical reconstruction approaches for EC using the EC data. In total, four approaches are investigated; two of them are discussed below, and the other two are discussed in the Supplement. The first method is direct regression (M1), which applies the relationship obtained from Fig. S9 to reconstruct EC:
Then, reconstructed OC can be obtained by subtracting reconstructed EC from TC:
Further reconstruction methods may deconstruct EC into several terms based on analysis principles and apply regression only on the unknown terms. Since only a partial regression is involved, theoretically, this approach can provide more accurate reconstruction results. Relationships found in Sect. 3.2 can also be used to refine the reconstruction.
The second approach (M2) employs partial regression. In Eq. (3), PC is the only unknown term on the right-hand side. As shown in Fig. S10, PC is well correlated with PC, which is known from NIOSH analysis. Therefore, Eq. (3) can be approximated as
Regression parameters for OC and EC reconstruction equations.
Approach | 2011–2013 | 2011–2012 | 2011 | 2012 | 2013 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
a | b | a | b | a | b | a | b | a | b | ||||
by season | Spring | 2.07 | 0.11 | 2.12 | 2.32 | 0.01 | 1.82 | 0.03 | 1.63 | 0.74 | |||
Summer | 1.77 | 0.19 | 1.86 | 0.14 | 1.97 | 0.13 | 1.72 | 0.16 | 1.63 | 0.24 | |||
Fall | 2.17 | 0.33 | 2.17 | 0.21 | 2.10 | 0.08 | 2.20 | 0.44 | 1.59 | 1.37 | |||
Winter | 2.12 | 0.25 | 2.19 | 0.16 | 2.08 | 0.58 | 1.95 | 0.14 | 1.99 | 0.39 | |||
by site | Roadside | MK | 0.99 | 3.39 | 1.23 | 2.20 | 0.90 | 3.86 | 1.99 | 0.73 | 4.87 | ||
M1 | Urban | TW | 2.16 | 2.35 | 2.39 | 2.15 | 1.75 | 0.54 | |||||
YL | 2.33 | 2.72 | 2.93 | 2.30 | 1.65 | 0.55 | |||||||
CW | 2.09 | 0.13 | 2.23 | 2.33 | 2.11 | 0.07 | 1.8 | 0.44 | |||||
TC | 2.24 | 2.24 | 2.39 | 2.01 | 2.20 | 0.02 | |||||||
Urban sites | 2.20 | 2.26 | 2.37 | 2.07 | 2.00 | 0.16 | |||||||
combined | |||||||||||||
Suburban | WB | 2.63 | 0.05 | 2.65 | 2.69 | 0.01 | 2.55 | 2.74 | 0.10 | ||||
by season | Spring | 1.92 | 0.04 | 2.19 | 0.00 | 2.26 | 0.03 | 0.94 | 0.13 | 0.98 | 0.34 | ||
Summer | 1.82 | 0.02 | 2.15 | 0.00 | 2.09 | 2.15 | 0.07 | 1.14 | 0.04 | ||||
Fall | 2.33 | 0.16 | 2.05 | 0.12 | 1.76 | 0.11 | 2.29 | 0.20 | 0.03 | 1.72 | |||
Winter | 1.92 | 0.11 | 1.99 | 0.02 | 1.84 | 0.31 | 1.80 | 0.02 | 1.88 | 0.18 | |||
by site | Roadside | MK | 1.96 | 2.00 | 1.78 | 1.51 | 1.83 | ||||||
M2 | Urban | TW | 2.02 | 2.01 | 1.94 | 2.15 | 2.10 | ||||||
YL | 2.14 | 2.01 | 2.08 | 1.90 | 0.03 | 2.33 | |||||||
CW | 2.42 | 2.51 | 2.4 | 0.16 | 2.73 | 2.31 | |||||||
TC | 2.26 | 2.23 | 0.00 | 2.25 | 1.98 | 0.08 | 2.35 | ||||||
Urban sites | 2.11 | 2.10 | 2.09 | 2.09 | 0.00 | 2.13 | |||||||
combined | |||||||||||||
Suburban | WB | 2.65 | 0.11 | 2.74 | 0.07 | 2.86 | 0.03 | 2.47 | 0.14 | 2.70 | 0.14 |
The two reconstruction method equations are ; . Regression parameters are derived from 2011–2013 data. Regression parameters are derived from 2011–2012 data. Regression parameters are derived from a single year's data.
M2 can be further improved if chemical composition data are available. As discussed above, the abundance of K and Fe can affect EC discrepancy. To reflect the contributions from these factors, PC, K, and Fe are included to approximate PC by multiple linear regression (MLR), then Eq. (3) can be rewritten as , , and are MLR coefficients. K is measured by ion chromatography, and Fe is detected by X-ray fluorescence.
An alternative reconstruction method (M3) is discussed in the Supplement. In brief, M3 is based on the linear relationship between (PC–PC and (PC–PC for reconstruction.
Comparison of reconstructed EC and measurement EC in the year 2013. (a) Regression by season-specific parameters using M1. (b) Regression by site-specific parameters using M1. (c) Regression by season-specific parameters using M2. (d) Regression by site-specific parameters using M2.
[Figure omitted. See PDF]
Reconstruction of 2013 OC and EC using parameters from 2011–2012 data
In this section, blind tests are performed to compare the performance of the two reconstruction methods (M1 and M2). Results of M2 1 and M3 reconstruction approaches are discussed in the Supplement. Data from 2011–2012 are used to obtain the necessary parameters (a and b) for M1 and M2 as shown in Eqs. (6) and (8), respectively. Since these parameters may vary temporally and spatially, two scenarios are considered for parameterization: scenario 1, seasonal specific parameters for each season with samples from all sites; scenario 2, site-specific parameters for all samples from a site or combined sites with a similar site characteristic. Detailed parameters are summarized in Table 2. These parameters are then applied to NIOSH data in 2013, and reconstructed EC and OC concentrations are calculated and compared with measured 2013 EC and OC to evaluate the performance of OC and EC reconstruction by the two scenarios. Since two scenarios are considered in each reconstruction method, there are four combinations of reconstruction results for M1 and M2.
Reconstructed EC by M1 is compared with measured EC in Fig. 7a and b. The of the season-specific (Fig. 7a) and site-specific reconstruction (Fig. 7b) are comparable with each other. Reconstructed EC is also compared with measured EC using histograms as shown in Fig. S15. The mean concentration by site-specific reconstruction agrees better than the season-specific reconstruction. The frequency distribution of the relative difference of reconstructed vs. measured EC exhibits a similar distribution between the season- and site-specific reconstructions (Fig. S16). OC reconstruction by M1 is shown in Fig. 8a and b, revealing reconstruction by site-specific parameters can increase the , with a tradeoff of higher average bias (slope 1.14). The seasonal or site-specific parameters yield similar reconstructed OC distributions as shown in Figs. S17 and S18. The OC EC ratios reconstructed by M1 are overestimated by a factor of 2 as shown by the slopes in Fig. 9. The reconstructed OC EC distribution is significantly broader than the measured OC EC ratios as shown in Figs. S19 and S20. This is an expected result of reconstructed OC and EC inherently having bias of opposite signs (i.e., if reconstructed OC is biased higher, then reconstructed EC would be biased lower), amplifying the bias in the ratio quantity.
Results of EC reconstruction by M2 are shown in Fig. 7c and d. Slopes by M2 are the closest to the unity of all the methods, implying that M2 can provide better accuracy than M1. M2 reconstruction by site exhibits the highest among all reconstruction scenarios. The superior performance of M2 by site-specific parameters is also evidenced by the sharpened distribution peak around zero for the relative difference of measured and reconstructed EC (Fig. S16d). OC reconstruction by M2 using site-specific parameters (Fig. 8d) yields a higher than the season-specific scenario (Fig. 8c). The OC relative difference distribution is sharpest in the site-specific-parameters scenario as shown in Fig. S18d. The OC EC ratios reconstructed by M2 are underestimated by 22 to 72 % as shown in Fig. 9, with a low ranging from 0.3 to 0.46. The OC EC bias is also evidenced by significantly different histograms between the distinctly sharper peak of the reconstructed OC EC compared with measured OC EC (Fig. S19c and d).
Reconstruction of OC calculated using Eq. (7). (a) Reconstruction by season-specific parameters using M1. (b) Reconstruction by site-specific parameters using M1. (c) Reconstruction by season-specific parameters using M2. (d) Reconstruction by site-specific parameters using M2.
[Figure omitted. See PDF]
Reconstruction results of OC EC. (a) Reconstruction by season-specific parameters using M1. (b) Reconstruction by site-specific parameters using M1. (c) Reconstruction by season-specific parameters using M2. (d) Reconstruction by site-specific parameters using M2.
[Figure omitted. See PDF]
From the comparisons shown above, it is obvious that the M2 site-specific-parameters scenario can provide the best performance in OC and EC reconstruction, evidenced by regression slopes being closest to unity and the sharpest frequency distribution histograms of OC or EC differences between reconstructed and measured values. However, the OC EC ratio is not well reproduced by the two methods; it is overestimated and underestimated by M1 and M2, respectively.
Comparison of SOC by NIOSH and IMPROVE. (a) SOC estimation from NIOSH TOT data. (b) SOC estimation from IMPROVE TOR data. (c) The relationship between SOC and SOC.
[Figure omitted. See PDF]
Histogram comparison of original SOC (in red) with SOC (in blue) reconstructed by M1 (a) and by M2 (c). Scatterplot comparison of original SOC (in axis) with SOC (in axis) reconstructed by M1 (b) and by M2 (d).
[Figure omitted. See PDF]
To investigate the stability of various parameters used in the two reconstruction scenarios, we also calculate reconstruction parameters for individual years from 2011 to 2013 as well as for the entire 3-year dataset as listed in Table 2. The reconstruction parameters are of similar values between years, implying these methods are robust for future reconstruction applications. The implementation of M1 to all urban site data (without site or seasonal specificity) yields the following equation, and this equation is recommended for urban site data conversion. For a heavily trafficked roadside environment, the recommended slope and intercept are 0.99 and 3.39, respectively. For suburban environments with light EC loadings, the recommended values are 2.63 for slope and for intercept.
The M2 site-specific parameters exhibit weaker site dependence than the M1 method, making M2 more suitable for expanding its application in other regions. As a result, M2 site-specific parameters obtained from the 3-year dataset are recommended for future reconstruction applications in Hong Kong (Table 2). The equation for urban environments is shown below: We note that the AEC, OC4, and PC inputs required in M2 are not always available for data users, as they are typically not reported by analysis laboratories.
Similarly, M2 1 site-specific parameters obtained from the 3-year dataset are recommended for future reconstruction applications in Hong Kong if K and Fe data are available (Table S4). The equation for urban environments is given below: Monthly variations of measured and reconstructed IMPROVE TOR EC and OC (M2, site-specific parameters) are shown in Fig. S21, clearly showing the reconstructed OC and EC data can reproduce the monthly trend quite well as compared with the measured data. This demonstrates that the reconstruction equations can provide a means to establish temporal trends for OCEC data produced using different analysis protocols.
Implications for secondary OC (SOC) estimation
The EC tracer method (Turpin and Huntzicker, 1995) is a widely used approach for SOC estimation since it only requires measured OC and EC as input: where (OC EC) is the OC EC ratio in freshly emitted combustion aerosols, OC and EC are from the measurements, and OC is the OC fraction from non-combustion sources (i.e., biogenic emissions). Since the OC is usually small, it is considered as zero to simplify the calculation in our study. The key to the EC tracer method is to estimate a proper (OC EC). Our previous study proved that the minimum R squared method (MRS) is more accurate than the conventional subset percentile or minimum OC EC ratio approaches (Wu and Yu, 2016). Therefore, MRS is employed for SOC calculation in this study. In this section, two aspects are discussed regarding SOC estimation: (1) variability of OC and EC by different protocols and the impacts on SOC estimation and (2) the usability of reconstructed EC and OC for SOC estimation.
Since the proportion of different primary emission sources is expected to vary by season, (OC EC) is calculated by MRS for each season (Table S3) using all 3 years of data (2011–2013). As shown in Fig. 10, SOC by NIOSH TOT (mean concentration: 4.70 g m is higher than by the IMPROVE TOR protocol (mean concentration: 2.66 g m. On average, SOC is 1.67 times higher than SOC as suggested by the regression slope in Fig. 10c. Although the absolute SOC concentrations by the two protocols are quite divergent, the (0.61) suggests that the two SOCs are moderately correlated. WSOC has been recognized as a good indicator of SOC formation (Sullivan et al., 2004), but WSOC contribution from primary emission is not negligible (Graham et al., 2002). Instead of using WSOC directly, we use secondary WSOC (SWSOC) as an indicator to verify the SOC results. SWSOC can be calculated from the following equation: In Eq. (14), sugars – which include levoglucosan, mannosan, and galactosan – are used as a tracer to derive SWSOC based on the primary ratio (5.28, Fig. S22) obtained from a biomass burning source profile measured in the PRD region (Lin et al., 2010). The relationship between SWSOC and SOC is examined in Fig. S23 for the WB site where sugars and WSOC data are available. SWSOC accounts for 61 % of SOC, which is comparable with the WSOC SOC ratio observed in Beijing (50–70 %) by Cheng et al. (2011b). The SWSOC-to-SOC regression slope is close to unity (0.92), implying that SOC by IMPROVE TOR could be underestimated. SOC by both SOC and SOC is well correlated with SWSOC, confirming the significant contribution of WSOC to SOC in this region. SOC exhibits a higher correlation ( 0.92) with WSOC than SOC ( 0.86), which is in good agreement with the study in Beijing (Cheng et al., 2011b), suggesting that NIOSH TOT might be more reasonable for SOC estimation.
The usability of reconstructed EC and OC (using M1 and M2) for SOC estimation is investigated. Results of M2 1 and M3 are discussed in Supplement. To account for the temporal variations of (OC EC), seasonal (OC EC) values are calculated using OC and EC reconstructed by M1 and M2 (Table S3). These (OC EC) values are then subject to SOC estimation following Eq. (13). It is very clear that the frequency distribution of reconstructed SOCs deviates from the SOC derived from measured OC and EC (Fig. 11). The SOC by M1 is higher than the original SOC, evidenced by average concentrations (3.53 vs. 2.66 g m and also confirmed by the regression slope (1.35). On the other hand, SOC by M2 is underestimated by 30–40 %. The moderate (Fig. 11d) also suggests the SOC by reconstructed EC and OC is poorly correlated with SOC by measured EC and OC. The significant bias and moderate correlations suggest that reconstructed EC and OC are not suitable for SOC estimation.
Conclusions
In this study, we use a large dataset that has good temporal (3 years) and spatial coverage (roadside, urban, rural) in Hong Kong to investigate the OC and EC determination discrepancy between NIOSH TOT and IMPROVE TOR protocols. NIOSH TOT reported lower EC (higher OC) than IMPROVE TOR. The divergence between the two protocols is attributed to two effects: thermal effect and optical method effect. The thermal effect is due to the higher PIMT in NIOSH (870 C) than IMPROVE (550 C) and the allocation of the OC4 fraction. The optical method effect is a result of different laser signals used by the two protocols (laser transmittance by NIOSH vs. laser reflectance by IMPROVE).
The equivalence between AEC and sum of OC4 and AEC is confirmed in the current study, and by offsetting the discrepancy from the thermal effect (OC4, the contribution from laser correction can be quantified. It is found that on average the thermal effect accounted for 83 % of the EC disagreement, while 17 % is attributed to the optical method effect. The contribution of the two effects exhibits a clear seasonal dependency, with a more pronounced optical method effect in spring and winter ( 35 %).
The intensity of biomass burning influence can affect EC divergence between the two protocols. Samples influenced by biomass burning (evidenced by higher K EC ratio) come with higher OC4 abundance (higher OC4 TC ratio), leading to larger EC divergence between the two protocols. The abundance of metal oxide in samples can also affect EC discrepancy, with a larger EC difference observed when a higher fraction of metal oxide is present in the ambient samples.
Four IMPROVE TOR EC reconstruction approaches (M1, M2, M2 1, and M3) are proposed. For each approach, two parameterization scenarios are considered, including season-specific parameters and site-specific parameters. The implementation of M1 to all urban sites (without considering seasonal specificity) yields the following equation: Considering site specificity yields slightly better reconstruction performance, with the site-specific slope value varying from 2.16 to 2.33 for the urban sites. The suburban site produces a higher slope value (2.63), while the roadside (MK) data produce a noticeably lower slope value (0.99). Hence, roadside samples (i.e., typically significant EC loadings) need to be processed separately and applied its own site-specific parameters for reconstruction when using the M1 equation. The comparisons show that M2 1 with site-specific parameters provides the best reconstruction results, and the regression parameters are given in Tables 2 and S4.
SOC estimation using OC and EC by the two protocols is compared. Based on the SWSOC-to-SOC ratio and correlation coefficients, it is found that SOC concentrations derived from NIOSH TOT are likely more reasonable than those from IMPROVE TOR. The reconstructed EC and OC for SOC estimation are shown to be unsuitable due to the poor reconstruction of the OC EC ratio.
Recommendations for applying OCEC reconstruction
It should be noted that the conversion equations established in this work are based on the fact that all OCEC data analysis was done by the same analyzer. Other instrument-specific parameters might influence the regression if multiple instruments are used in obtaining the OCEC data. For example, temperature offset has been found to vary by instrument in different labs (Panteliadis et al., 2015). Oven soiling and aging have also been found to have an optical influence that introduces uncertainties in the results (Chiappini et al., 2014).
Four reconstruction approaches are proposed in this study; the selection of which to use depends on the degree of availability of the dataset. If the dataset has only OC and EC concentrations and no detailed carbon fraction information, M1 is preferred. If the dataset also comes with carbon fraction information, M2 and M3 are suggested. If chemical speciation data are available, such as K and Fe, M2 1 is recommended to minimize the effect from biomass burning and metal oxides.
Data availability
OC, EC, inorganic ions and elements data used in this study are available from Hong Kong Environmental Protection Department ([email protected]).
The Supplement related to this article is available online at
Acknowledgements
This project was partially supported by the Hong Kong Environment Protection Department (HKEPD) (AS 10-231, 11-03973, and 12-04384). We thank HKEPD for making available the data for this work. We are indebted to Peter Louie for his relentless efforts in pushing for the best possible PM speciation measurements in Hong Kong. Edited by: W. Maenhaut Reviewed by: two anonymous referees
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2016. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Organic carbon (OC) and elemental carbon (EC) are operationally defined by analytical methods. As a result, OC and EC measurements are protocol dependent, leading to uncertainties in their quantification. In this study, more than 1300 Hong Kong samples were analyzed using both National Institute for Occupational Safety and Health (NIOSH) thermal optical transmittance (TOT) and Interagency Monitoring of Protected Visual Environment (IMPROVE) thermal optical reflectance (TOR) protocols to explore the cause of EC disagreement between the two protocols. EC discrepancy mainly (83 %) arises from a difference in peak inert mode temperature, which determines the allocation of OC4
while M2 deconstructs EC
where AEC
While both M1 and M2 are acceptable, M2 with site-specific parameters provides the best reconstruction performance. Secondary OC (SOC) estimation using OC and EC by the two protocols is compared. An analysis of the usability of reconstructed EC
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details



1 Division of Environment, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
2 Environmental Central Facility, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
3 Department of Chemistry, Hong Kong University of Science and Technology, Hong Kong, China
4 Division of Environment, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China; Environmental Central Facility, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China; Department of Chemistry, Hong Kong University of Science and Technology, Hong Kong, China