Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Featured Application

Semi-supervised learning can effectively be used to detect the chest X-rays affected by COVID-19.

Abstract

The advent of the COVID-19 pandemic has resulted in medical resources being stretched to their limits. Chest X-rays are one method of diagnosing COVID-19; they are used due to their high efficacy. However, detecting COVID-19 manually by using these images is time-consuming and expensive. While neural networks can be trained to detect COVID-19, doing so requires large amounts of labeled data, which are expensive to collect and code. One approach is to use semi-supervised neural networks to detect COVID-19 based on a very small number of labeled images. This paper explores how well such an approach could work. The FixMatch algorithm, which is a state-of-the-art semi-supervised classification algorithm, was trained on chest X-rays to detect COVID-19, Viral Pneumonia, Bacterial Pneumonia and Lung Opacity. The model was trained with decreasing levels of labeled data and compared with the best supervised CNN models, using transfer learning. FixMatch was able to achieve a COVID F1-score of 0.94 with only 80 labeled samples per class and an overall macro-average F1-score of 0.68 with only 20 labeled samples per class. Furthermore, an exploratory analysis was conducted to determine the performance of FixMatch to detect COVID-19 when trained with imbalanced data. The results show a predictable drop in performance as compared to training with uniform data; however, a statistical analysis suggests that FixMatch may be somewhat robust to data imbalance, as in many cases, and the same types of mistakes are made when the amount of labeled data is decreased.

Details

Title
Investigating the Performance of FixMatch for COVID-19 Detection in Chest X-rays
Author
Sajun, Ali Reza  VIAFID ORCID Logo  ; Zualkernan, Imran  VIAFID ORCID Logo  ; Donthi Sankalpa
First page
4694
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20763417
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2662908652
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.