1. Introduction
The accurate detection of glucose is of great importance to blood glucose control, biochemical analysis, and food safety for diabetic patients [1]. The widely used enzymatic glucose detection is limited by the biochemical characteristics of the enzyme and is very sensitive to temperature, pH, humidity, and other conditions. In order to improve the accuracy of enzyme sensor detection, the development of new non-enzymatic glucose sensors has become a research focus in recent years [2,3]. Varied materials have been employed as substrates in glucose sensors. TiO2 nanotubes (TNTs), as a new functional material in the field of biosensors, can be prepared at low temperatures and their tube length and diameter are easy to accurately control, which makes them an excellent carrier electrode for nanometer-sensitive materials [4]. Moreover, anodized TNTs are non-toxic with a good biological affinity and large specific surface area. In addition, their directional tubular and ordered hollow structures can provide sufficient adsorption space [5]. However, the low electron conduction efficiency of TiO2 nanotubes due to their semiconductor nature significantly restricts their wide application, where additional modifications are generally required to increase the conductivity.
As for the catalytic materials for glucose oxidation, metal nanoparticles have been widely studied due to their high reactivity and simple preparation among non-enzymatic sensors. Among them, the earth-abundant and non-toxic Ni has a low cost and a strong specific catalytic ability to oxidize glucose, particularly in alkaline environments, compared with Pt, Au, and Cu [3,6]. At present, most Ni-based sensors constructed from Ni nanomaterials are mainly used to form a higher valence hydroxide (NiOOH) in alkaline media to carry out the catalytic oxidation process. Ni nanomaterials are usually loaded on graphene, carbon nanotubes, carbon nanofibers, disordered graphite carbon, diamond, and other carbon-based carrier electrodes using chemical or electrochemical deposition [7,8,9,10,11,12]. Compared with the Ni plate, Ni nanoparticle-modified electrodes can significantly improve glucose detection sensitivity. For instance, Zeng et al. [13,14] and Liu et al. [15,16,17] loaded Ni nanoparticles and Ni/Cu nanoparticles on TiO2 nanotubes by electrodeposition, respectively, with excellent detection limits and sensitivity. However, when metal nanomaterials are loaded on the electrode by chemical or electrochemical deposition, the chemical bonding between the metal nanoparticles and carbon substrates is generally not so strong, resulting in a high interfacial migration energy barrier of electrons. Moreover, the metal nanoparticles are prone to migrate with aggregation, which greatly affects the activity and stability of the electrode [18]. Diamond-like carbon (DLC) film has excellent biocompatibility and chemical stability. It is a biologically inert material, which has good mechanical and friction resistance properties. Diamond-like carbon (DLC) thin films composed of sp2- and sp3-hybridized carbon show relatively high hardness, excellent biocompatibility, chemical inertness, and high corrosion resistance. By introducing impure elements, such as N and Ni, the doped DLC films can possess sufficient conductivity for electrochemistry, low double-layer capacitance, large potential window, low background current, high stability in challenging environments, and comparative resistance to deactivation by fouling [19]. Experimental results suggest that modified diamond-like carbon electrodes with a wide electrochemical window and low background current can be used as non-enzymatic glucose detection sensors [19,20,21]. In the meantime, DLC films can reduce internal stress to improve the quality of the films, and their performance can be efficiently improved and enhanced. More importantly, DLC can be prepared at low temperatures, has a very wide selectivity to the substrate, and does not require special treatment of the substrate, making it possible to further modify the TiO2 nanotubes without damaging the original TiO2 nanotube structure. In addition, metallic nanoparticles (NPs) or nanoclusters (NCs) loaded on the electrode surface represent obvious differences in physical and chemical properties from both substrate materials and isolated bulk metals and drastically increase the catalytic activity and sensitivity of the electrodes, resulting in the enhancement of the performance of biosensors [22,23,24]. Large surface areas and good electronic properties of dispersive metallic particles, such as Au and Ni, can accumulate charges and improve the electrochemical response of carbon electrodes in electrochemical glucose sensors [25,26,27,28].
In this work, we use the sputtered DLC layer to act as a fixed tool that is supposed to trap the Ni nanoparticles. The metal particles could be evenly dispersed and fixed within the carbon film, and the smooth surface can reduce the adsorption oxidation products. Sputtering at a substrate could form a local chemical combination of a two-phase interface, reducing the electron transfer resistance and improving the catalytic activity [29].
Therefore, we prepared TiO2 nanotubes (TNTs) using the anodic oxidation process and then modified the Ni-doped DLC film layer on the surface of the TiO2 electrode using magnetron sputtering technology to prepare the Ni-doped DLC-modified TiO2 nanotube composite structure electrodes (Ni-DLC/TNTs). Their structural composition and electrocatalytic oxidation performance of glucose were systematically investigated.
2. Results and Discussion
2.1. Electrode Characteristics
Figure 1 shows the SEM morphology of the TNTs, Ni/TNTs, and Ni-DLC/TNTs. As can be seen in Figure 1a, the TiO2 nanotubes have an opening at the top and are arranged vertically on the Ti surface in an orderly manner, with a diameter of less than 100 nm. As can be seen in Figure 1b, after the deposition of Ni nanoparticles, the Ni NPs were dispersed and uniformly distributed on the surface of the TiO2 nanotubes. This is because the periodic variation in the pulse electroplating current was conducive to eliminating the cathode concentration polarization and greatly improving the nucleation rate. On the other hand, the current was turned on and off during the pulse electrodeposition process. Such periodic alternation is very beneficial to the adsorption and desorption of ions in the electrolyte and the recrystallization of particles [30], which reduces the possibility of nanoparticles, reunion, and fine grains. As can be seen in Figure 1c, after the sputtering deposition of Ni-doped DLC film on the surface of the nanotubes, the opening end of the nanotubes decreased and the surface retained the morphology and roughness of the substrate.
The element composition of the electrode was analyzed by EDX spectroscopy. Figure 2 shows the EDX results of the tube on the surfaces of TNTs, TNT-Ni, and TNT-Ni/DLC. EDX can collect the element information at a depth of 1 μm, which is collected in the area of the tube openings, respectively (as marked in Figure 1). Only Ti and O were detected on the surface of the samples without electrodeposition and Ni was detected after electrodeposition. As can be seen in Figure 2, element C was detected on the surface of the TNT-Ni/DLC composite electrode, and it was found that the content of element Ni was greatly increased because the deposited DLC film was doped with Ni at the same time, which improves the performance of the electrode compared to the TNT-Ni electrode.
Figure 3 shows the Raman spectrum of the Ni-DLC/TNT electrode, where a typical diamond-like wide peak with two asymmetric broad peaks can be found. The D peak near the low wavenumber of 1360 cm−1 can be derived from the respiration mode of the ring sp2 C–C bond, whereas the G peak near the high wavenumber of 1580 cm−1 is derived from the stretching vibration mode of the chain-like sp2 C–C bond or annular sp2 C–C bond [31], indicating the successful deposition of the DLC layer on the electrode surface.
2.2. Performance of Electrode Electrocatalytic Oxidation of Glucose
Studies have shown that the catalytic mechanism of a Ni-based sensor is mainly due to the formation of a higher valence hydroxyl compound in alkaline media (NiOOH), which carries out the catalytic oxidation process. The specific reaction is as follows:
Ni + 2OH−
Ni(OH)2 + OH−
NiO(OH) + glucose
Therefore, before the electrochemical detection of glucose at the electrode, Ni/TNTs and Ni-DLC/TNTs were treated with 25 consecutive cyclic voltammetry (CV) cycles at a scanning rate of 50 mV s−1, and Figure 4 shows the CV curve of the Ni-DLC/TNT composite electrode. With the increase in the number of cycles, the oxidation peak current also increased gradually and the oxidation peak potential shifted positively, suggesting the formation of NiOOH.
Figure 5 shows the CV curves of the three electrodes, (a) TNTs, (b) Ni/TNTs, and (c) Ni-DLC/TNTs, in background electrolyte 0.5 M NaOH and 1 mM glucose (0.5 M NaOH) solutions, respectively, with a scan rate of 50 mV s−1. It can be seen that pure TiO2 nanotubes showed no redox activity. After modification with Ni nanoparticles, the Ni/TNT electrode had a Ni2+/Ni3+ redox peak. However, after modification with Ni-doped DLC film, the current of the redox peak greatly increased. This illustrates that the conductivity of the Ni-DLC/TNT electrode was further improved with the incorporation of DLC. This is because the deposition of the uniformly distributed Ni on the DLC increased the catalytic capacity and the steric resistance of the film, inhibiting the formation of the sp3 bond and increasing the proportion of sp2 [31,32,33]. When 1 mM glucose was added to the NaOH solution, the TNT electrode showed no response as pure TiO2 nanotubes have no catalytic activity for the oxidation of glucose, whereas the peak currents of the Ni/TNT and Ni-DLC/TNT electrodes increased. This is because, in the alkaline solution, the glucose was rapidly and specifically oxidized to gluconolactone in the presence of the Ni catalyst. To be specific, Figure 5b,c shows that the electrocatalytic oxidation response current of the Ni/TNTs was 0.07 mA, which increased to 0.21 mA for the Ni-DLC/TNTs, indicating enhanced activity of the Ni-DLC/TNTs.
In order to further explore the mass transfer characteristics in the process of electrochemical glucose oxidation, CV tests were carried out at a scanning rate of 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140, and 150 mV/s, respectively, whereas the Ni-TNT electrode and Ni-DLC/TNT composite electrodes were treated with a mixture of 0.5 M NaOH and 1 mM glucose solution (0.5 M NaOH), respectively. As shown in Figure 6, with the increase in the scanning rate, the oxidation peak current and reduction peak current increased gradually with reversibility. Moreover, the oxidation peak potential shifted positively, whereas the reduction peak potential shifted negatively, and the potential difference (△Ep) between the oxidation peak potential and reduction peak potential increased gradually. This is because, at a higher scanning rate, the electrode required a larger overpotential to achieve the same electron transfer rate [34]. The oxidation peak current and reduction peak current in the CV curve were plotted as a function of the square root of the scanning rate, where a good linear relationship was found, as seen in Figure 6b,d, indicating that both the Ni-TNT electrode and Ni-DLC/TNT composite electrode detected glucose as a typical electrochemical process of diffusion mass transfer [35].
In order to compare the electrocatalytic activity of the TNT electrode, Ni-TNT electrode, and Ni-DLC/TNT composite electrode for glucose, chronoamperometry was employed. The obtained i-t curve results are shown in Figure 7 with an applied potential of 0.55 V. The solution was kept in a state of constant agitation during the test. It can be seen from the i-t curve that the current response of the TNT electrode is a straight line, which indicates that pure TiO2 nanotubes do not have the ability to catalyze the oxidation of glucose, whereas the Ni-TNT and Ni-DLC/TNT composite electrodes have a relatively larger response current. The current response of the catalytic oxidation of glucose at each electrode is as follows: Ni-DLC/TNTs > Ni-TNTs > TNTs, which is consistent with the CV results in Figure 5.
The performance of the Ni-DLC/TNT composite electrode for the electrocatalytic oxidation of glucose was further analyzed as shown in the i-t curve. It can be seen in Figure 8 that the current response can reach a stable state within 5 s, indicating that the electrocatalytic oxidation of glucose by the Ni-DLC/TNT composite electrode is rapid. With the increase in the concentration of glucose in the solution, the current response of the electrode also increased step by step. As can be seen from the illustration in Figure 7, when the glucose concentration was lower than 5 μM, the electrode still generated an obvious current response, indicating an excellent sensitivity of the Ni-DLC/TNT composite electrode at a low concentration of glucose.
A comparison of the obtained electrodes and literature on similar non-enzymatic glucose sensors can be seen in Table 1. Based on this comparison, the composite electrode has better selectivity and stability than other similar electrodes in the literature.
Taking the concentration of glucose in solution as the abscissa and the corresponding current response as the ordinate, Figure 8 was plotted. Linear fitting was performed to obtain two linear fitting curves in the ranges of high and low concentrations:
(1) When the concentration of glucose ranged from 0.99 mM to 3.00 mM, the linear fitting equation was as follows: I (μA) = 265.944 Cglucose(mM) + 89.506, and the linear correlation coefficient was R2 = 0.9981.
(2) When the concentration of glucose ranged from 3.00 mm to 22.97 mM, the linear fitting equation was as follows: I (μA) = 138.723 Cglucose(mM) + 443.569, and the linear correlation coefficient was R2 =0.9921.
Since the sensitivity is the ratio of the slope of the linear fitting curve to the electrode area and the physical surface area of the electrode was 0.25 cm2, the sensitivity of the electrode was estimated to be 1063.78 μA·mM−1·cm−2 with a glucose concentration range between 0.99 mM and 3.00 mM, whereas the sensitivity of the electrode was 554.89 μA·mM−1·cm−2 and in the range of 3.00–22.97 mM. The reason the sensitivity of the electrode decreased in a high concentration range can be attributed to the following reasons: The intermediate products generated by the oxidation of glucose were adsorbed on the surface of the composite electrode during the electrochemical testing process, leading to the obstruction and inhibition of the adsorption and diffusion of glucose molecules to the surface of the electrode [46]. In addition, according to the background current signal measured by the electrode in a blank solution 11 times, the standard deviation was 0.18 μA·cm−2. According to the calculation formula of the detection limit, LOD = 3σ/S, with S the sensitivity and σ the relative standard deviation, and with a principle of S/N = 3, the detection limit of the Ni-DLC/TNT composite electrode was calculated to be 0.53 mM.
Another major problem faced by non-enzymatic sensors is the interference of other organic substances in the blood because these substances can be oxidized with a potential similar to glucose; therefore, we further investigated the anti-interference performance of the TNT-Ni/DLC composite electrode. In solution, the chronoamperometry method was used and the applied potential was 0.55 V, glucose (1 mM), DA (0.1 mM), UA (0.1 mM), AA (0.1 mM), galactose (0.1 mM), and glucose (1 mM) were added in turn to study their influence on the current response and the results are shown in Figure 9a.
It can be seen from the results that other than glucose, the interferential current signals compared to the current signal of glucose were almost negligible, suggesting a strong anti-interference of the electrode. Under a 0.55 V voltage, the electrodes only showed weak oxidation ability to other interfering substances in the blood of the human body, which ensured accuracy in the process of biological detection.
The long-term stability of the electrode is also an important index to determine whether the electrode has application potential. The current response of the Ni-DLC/TNT composite electrode in a 1 mM glucose solution was tested by the time current method once a week for four consecutive weeks. During the test, the solution was kept in a state of constant agitation in the supporting electrolyte and the applied potential was 0.55 V. Moreover, the electrode was stored at room temperature in air during the non-test period, and the stability of the electrode was checked over time from the SEM image of the electrode after experiments. The test results are shown in Figure 9b. It can be seen that in each continuous 1 h test process, the current response showed hardly any reduction, and the current response of the composite electrode remained at 82.6% of the initial current response after one month, indicating that the Ni-DLC/TNT composite electrode had good long-term stability. Compared with the electrodeposited nanoparticles and the matrix by adsorption or another physical combination, the Ni in the Ni-DLC/TNT electrode prepared in this paper was closely bound to the DLC, which was firmly fixed in the film by the DLC and formed a uniform distribution. In addition, the hollow TiO2 carrier electrode played the role of stable fixation for the DLC film. This avoids the shedding and loss of electrodeposited nanoparticles and the reduction in the current response of the electrode in the electrochemical test, which greatly improves the long-term stability of the electrode.
3. Materials and Methods
3.1. Reagents
Potassium chloride (0.5 mol/L, 99.97%) and sodium hydroxide (0.5 mol/L, 99.5%) were all purchased from Tianjin Recovery Technology Development Co., Ltd., Tianjin, China, glucose (0.99–3 mM, 99.5%), dopamine (0.1 mM, ≥95%), ascorbic acid (0.1 mM, 99%), uric acid (0.1 mM, 98%), and lactose (0.1 mM, 99.6%) were all purchased from Sigma-Aldrich Co., Ltd., St. Louis, MO, USA. All reagents were analytically pure without any further purification. All solutions were prepared using ultra-pure water (18.2 MΩ ∗ cm). The supporting electrolyte was a 0.5 M NaOH solution.
3.2. Sample Preparation
Firstly, the polished Ti sheet (PT 99.99%, Hunan Xiangtian Titanium Industry Co., Ltd., Changsha, China) (5 × 5 × 1.5 mm) was soaked in the chemical polishing solution NaF:HNO3:H2O = 2:18:80(m/m) for 1–3 min to remove the oxide layer. Then, the treated Ti sheet was cleaned by sonication in deionized water for 5 min and dried. The treated Ti sheet was used as the anode. The TiO2 nanotube array (TNTs) electrodes were obtained by anodizing at 25 V for 1 h in glycerol solution containing 0.2–7 M NH4F using stainless steel plates as the cathode placed 30 mm away from the anode. Secondly, Ni nanoparticles were deposited on TiO2 nanotube arrays using the pulsed electrodeposition method and were prepared according to the literature [47]. The experiment was carried out in a three-electrode system, with the TNT electrode as the working electrode, nickel sheet as the counter electrode, and Ag/AgCl/saturated KCl electrode as the reference electrode. The electrolyte contained 300 g/L NiSO4·6H2O, 45 g/L NiCl2·6H2O, and 37 g/L H3BO3, and the temperature was maintained at 38 °C. The cathode pulse current density and time were −160 mA/cm2 and 8 ms, the anode pulse current density and time were set at +160 mA/cm2 and 2 ms, the current turn-off time was 1000 ms, and the total deposition time was 10 min. After electrodeposition, the sample was rinsed with deionized water and dried. Finally, Ni-doped DLC films (Ni-DLC/TNTs) were prepared on the surface of the TNT electrode using a radio frequency (RF) bias-assisted magnetron sputtering process. The specific deposition process was as follows: The flow ratio of Ar gas (99.999%) and C2H2 (99.999%) was 16:6 sccm, the deposition pressure was 1.0 Pa, the RF power was 200 W, the bias voltage was 25 V, and the sputtering time was 5 min. The steps in the sample preparation are shown below in Figure 10.
3.3. Sample Characterization and Electrochemical Detection
The surface morphology of the samples was analyzed by field emission scanning electron microscopy (FESEM, NOVA Nanosem230), the surface composition of the samples was characterized by energy-dispersive X-ray spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS, ESCALAB 250Xi) was used to characterize and analyze the chemical composition of the surface of the samples. Laser Raman spectroscopy (Labram HR 800,532 nm, 10 mW) was used to characterize the proportion of sp2 and sp3 in the DLC samples. All the electrochemical performance characterization experiments were performed at the electrochemical workstation CHI660E (CH Instruments, Shanghai Chenhua Instrument Corp., Shanghai, China) at room temperature using a three-electrode system. The packaged sample (5 × 5 mm2) was used as the working electrode, a platinum plate (10 × 10 mm2) was used as the counter electrode, and an Ag/AgCl was used as the reference electrode.
4. Conclusions
In this manuscript, TiO2 nanotubes were prepared by anodic oxidation, and the composite electrode modified by Ni-DLC was prepared by Ni electrodeposition and subsequent DLC sputtering. With TiO2 as the substrate electrode, the hollow porous structure improved the stability of the modifying film by anchoring. At the same time, the synergistic effect of Ni and DLC improved the stability and catalytic activity of Ni. The results of the glucose catalytic oxidation of the composite electrode showed that there were two linear ranges. The sensitivity of the composite electrode was 1063.78 μA·mM−1·cm−2 when the glucose concentration range was 0.99 mM–3.00 mm, the sensitivity of the electrode was 554.89 μA·mM–1·cm–2, and the LOD was 0.53 μM (S/N = 3) in a glucose concentration range of 3.00–22.97 mM. The composite electrode had good selectivity and stability, which indicates that the electrode has positive application prospects in the determination of non-enzymatic glucose.
Conceptualization, methodology, Y.K.; software, X.R.; validation, formal analysis, investigation, resources, data curation, writing—original draft preparation, writing—review and editing, visualization, supervision, Y.K.; writing, revising, Y.L.; Resource, Z.Y. All authors have read and agreed to the published version of the manuscript.
Not applicable.
Not applicable.
Not applicable.
The authors declare no conflict of interest.
Samples of the compounds are not available from the authors.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Figure 1. SEM morphology of different electrode surfaces: (a1,a2) TNT; (b1,b2) Ni/TNT; and (c1,c2) Ni−DLC/TNT membrane layers. The elemental analysis in Figure 2 demonstrates the successful deposition of Ni with an atomic ratio of 4.1% for Ni/TNTs and 6.13% for Ni−DLC/TNTs, respectively, after magnetron sputtering. The three red small box identifier showed that after the deposition of Ni nanoparticles, the Ni NPs were dispersed and uniformly distributed on the surface of the TiO2 nanotubes. As can be seen in Figure 1c, after the sputtering deposition of Ni−doped DLC film on the surface of the nanotubes, the opening end of the nanotubes decreased and the sur-face retained the morphology and roughness of the substrate.
Figure 2. EDX energy spectra 1, 2, and 3 correspond to the regions (red rectangle) marked on the surfaces of the TNT (a2), Ni−TNT (b2), and Ni−DLC/TNT (c2) electrodes in Figure 1, respectively. The illustration shows the types and contents of elements.
Figure 4. CV curves of Ni−DLC/TNT composite electrode solution were scanned continuously for 25 cycles at a scanning rate of 50 mV s−1 (0.5 mol/L sodium hydroxide solution as a medium).
Figure 5. CV curves of different electrodes in 0.5 M NaOH + 1 mM glucose mixed solution (red line) and 0.5 M NaOH solution (black line): (a) TNTs; (b) Ni−TNTs; (c) Ni−DLC/TNTs (all selected the second cycle of CV).
Figure 6. The CV curves of the Ni−TNT electrode (a,b) and (c,d) the Ni−DLC/TNT composite electrode at a scanning rate of 10−150 mV/s, the linear fitting graphs of the corresponding anode (Ipa) and cathode oxidation peak current (Ipc), and the square root of the scanning rate v1/2. TNT electrodes have no catalytic activity.
Figure 7. The i-t curves of the TNT electrode, Ni/TNT electrode, and Ni-DLC/TNT composite electrode when different concentrations of glucose solution were continuously added. The illustration shows the enlarged view at low concentrations.
Figure 8. The linear fitting curve and corresponding fitting equation of the current response of the Ni-DLC/TNT composite electrode and the corresponding glucose concentration are shown in the illustration as the enlarged fitting diagram at a low concentration.
Figure 9. (a) Anti-interference test results of Ni-DLC/TNT composite electrode; (b) Stability test of TNT-Ni/DLC composite electrode. The i-t curve in 1 mM glucose solution was measured once a week. The illustration shows the results of each test relative to the first test.
Comparison of the performance of the proposed sensor and those of similar ones described in the literature.
Electrode Material | Linear Range | Detection Limit (μM) | Sensitivity (μA·mM−1·cm−2) | Ref. |
---|---|---|---|---|
Ni-NDa/BDD | 0.2–12 μM; |
0.05 | 120; 35.6 | [ |
NiNPs/GNc | 5 μM–0.55 mM | 1.85 | 865 | [ |
NiONPs/GOd/GCE | 3.13 μM–3.05 mM | 1 | 1087 | [ |
NiO/Pt/ErGO/GCE | 50 μM–5.66 mM | 0.2 | 668.2 | [ |
Ni-MWCNTe/GCE | 3.2 μM–17.5 mM | 0.89 | 67.19 | [ |
Ni(OH)2graphene/GCE | 1–10 μM; 10 μM–10 mM | 0.6 | 494; 328 | [ |
NiCoO/CNTf | 0.01–0.93 mM; |
5 | 66.15; 15.43 | [ |
NiNPs/BDD | 10 μM–10 mM | 2.7 | 1040 | [ |
NiNPs/CNFg | 2 μM–2.5 mM | 1 | 420.4 | [ |
Ni-Rgo/GCE | 1–110 μM | - | 813 | [ |
Au/DLC:P | 0.5–25 mM | 300 | 37 | [ |
Au-DLC:N | 0.5–25 mM | 120 | - | [ |
CuO | 0.005–7.95 mM | 1 | 622.2 | [ |
AuNi/NX/MWCNT-21 | 1–60 mM | 0.063 | 662.93 | [ |
60–1900 mM | 0.285 | 147.22 | ||
Ni-NPs/GRE | 2–800 mM | 0.4 | 1387 | [ |
Cu-Ni/NF | 1−600 mM | 2 | 11,340.25 | [ |
Ni-DLC/TiO2 | 0.99–22.97 mM | 0.53 | 1063.78 | This work |
References
1. Wang, J. Electrochemical Glucose Biosensors. Chem. Rev.; 2008; 108, pp. 814-825. [DOI: https://dx.doi.org/10.1021/cr068123a] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/18154363]
2. Wang, G.; He, X.; Wang, L.; Gu, A.; Huang, Y.; Fang, B.; Geng, B.; Zhang, X. Non-enzymatic electrochemical sensing of glucose. Mikrochim. Acta; 2012; 180, pp. 161-186. [DOI: https://dx.doi.org/10.1007/s00604-012-0923-1]
3. Khalil, M.W.; Rahim, M.A.; Zimmer, A.; Hassan, H.B.; Hameed, R.M. Nickel impregnated silicalite-1 as an electro-catalyst for methanol oxidation. J. Electroanal. Chem. Interfacial Electrochem.; 1971; 31, pp. 39-49. [DOI: https://dx.doi.org/10.1016/j.jpowsour.2004.12.014]
4. Liu, X.; Yan, R.; Zhu, J.; Zhang, J.; Liu, X. Growing TiO2 Nanotubes on Graphene Nanoplatelets and Applying Thenanona-nocomposite as Scaffold of Electrochemical Tyrosinasebiosensor. Sens. Actuators B Chem.; 2015; 209, pp. 328-335. [DOI: https://dx.doi.org/10.1016/j.snb.2014.11.124]
5. Wang, J.W.; Xu, G.Q.; Zhang, X.; Lv, J.; Zhang, X.; Zheng, Z.; Wu, Y. Electrochemical Performance and Biosensor Application of TiO2 Nanotube Arrays with Mesoporous Structures Constructed by chemical Etching. Dalton Trans.; 2015; 44, pp. 7662-7672. [DOI: https://dx.doi.org/10.1039/C5DT00678C] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/25811301]
6. Wang, Q.; Zhang, Y.; Ye, W. Ni(OH)2/MoSx nanocomposite electrodeposited on a flexible CNT/PI membrane as an electrochemical glucose sensor: The synergistic effect of Ni(OH)2 and MoSx. J. Solid State Electrochem.; 2016; 20, pp. 133-142. [DOI: https://dx.doi.org/10.1007/s10008-015-3002-9]
7. Liu, Y.; Teng, H.; Hou, H.; You, T. Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode. Biosens. Bioelectron.; 2009; 24, pp. 3329-3334. [DOI: https://dx.doi.org/10.1016/j.bios.2009.04.032]
8. You, T.; Niwa, O.; Chen, Z.; Haya, K.; Tomita, M.; Hiro, S. An amperometric detector formed of highly dispersed Ni nanoparticles embedded in a graphite-like carbon film electrode for sugar determination. Anal. Chem.; 2003; 75, pp. 5191-5196. [DOI: https://dx.doi.org/10.1021/ac034204k]
9. Li, X.; Yao, J.; Liu, F.; He, H.; Ming, Z.; Nan, M.; Peng, X.; Zhang, Y. Nickel/Copper nanoparticles modified TiO2 nanotubes for non-enzymatic glucose biosensors. Sens. Actuators B Chem.; 2013; 181, pp. 501-508. [DOI: https://dx.doi.org/10.1016/j.snb.2013.02.035]
10. Zhang, Y.; Xiao, X.; Sun, Y.; Shi, Y.; Dai, H.C.; Ni, P.J.; Hu, J.T.; Li, Z.; Song, Y.H.; Wang, L. Electrochemical deposition of nickel nanoparticles on reduced graphene oxide film for nonenzymatic glucose sensing. Electroanalysis; 2013; 25, 959. [DOI: https://dx.doi.org/10.1002/elan.201200479]
11. Allendorf, M.D.; Medishetty, R.; Fischer, R.A. Guest molecules as a design element for metal-organic frameworks. MRS Bull.; 2016; 41, pp. 865-869. [DOI: https://dx.doi.org/10.1557/mrs.2016.244]
12. Bo, W.; Li, S.; Liu, J.; Wang, B. Preparation of nickel nanoparticle/graphene composites for non-enzymatic electrochemical glucose biosensor applications. Mater. Res. Bull.; 2014; 49, pp. 521-524.
13. Zeng, A.; Jin, C.; Cho, S.-J.; Seo, H.-O.; Kim, Y.-D.; Lim, D.-C.; Kim, D.-H.; Hong, B.-Y.; Boo, J.-H. Nickel nano-particle modified nitrogen-doped amorphous hydrogenated diamond-like carbon film for glucose sensing. Mater. Res. Bull.; 2012; 47, pp. 2713-2716. [DOI: https://dx.doi.org/10.1016/j.materresbull.2012.04.041]
14. Wang, Z.; Hu, Y.; Yang, W.; Zhou, M.; Hu, X. Facile One-Step Microwave-Assisted Route towards Ni Nanospheres/Reduced Graphene Oxide Hybrids for Non-Enzymatic Glucose Sensing. Sensors; 2012; 12, pp. 4860-4869. [DOI: https://dx.doi.org/10.3390/s120404860] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/22666063]
15. Liu, A.; Ren, Q.; Xu, T.; Ming, Y.; Tang, W. Morphology-controllable gold nanostructures on phosphorus doped diamond-like carbon surfaces and their electrocatalysis for glucose oxidation. Sens. Actuators B Chem.; 2012; 162, pp. 135-142. [DOI: https://dx.doi.org/10.1016/j.snb.2011.12.050]
16. Liu, A.; Liu, E.; Yang, G.; Tang, W. Electrochemical behavior of gold nanoparticles modified nitrogen incorporated diamond-like carbon electrode and its application in glucose sensing. Proceedings of the 2010 3rd International Nanoelectronics Conference (INEC); Hong Kong, China, 3–8 January 2010; pp. 336-337.
17. Wang, C.X.; Yin, L.W.; Zhang, L.Y.; Gao, R. Ti/TiO2 Nanotube Array/Ni Composite Electrodes for Nonenzymatic Amperometric Glucose Sensing. J. Phys. Chem. C; 2010; 114, pp. 4408-4413. [DOI: https://dx.doi.org/10.1021/jp912232p]
18. Xin, Y.; Zhen, C.; Shuf, C.; Chen, S.F.; Zhu, B. Synthesis of mesoporous CuO microspheres with core-in-hollow-shell structure and its ap-plication for non-enzymatic sensing of glucose. RSC Adv.; 2015; 45, pp. 131-138.
19. Liu, A.; Liu, E.; Yang, G.; Khun, N.W.; Ma, W. Non-enzymatic glucose detection using nitrogen-doped diamond-like carbon electrodes modified with gold nanoclusters. Pure Appl. Chem.; 2010; 82, pp. 2217-2229. [DOI: https://dx.doi.org/10.1351/PAC-CON-09-11-11]
20. Naragino, H.; Yoshinaga, K.; Tatsuta, S.; Honda, K. Improvement of conductivity by incorporation of boron atoms in hydrogenated amorphous carbon films fabricated by plasma CVD methods and its electrochemical properties. ECS Trans.; 2012; 41, pp. 59-68. [DOI: https://dx.doi.org/10.1149/1.3687438]
21. Jin, C.; Zeng, A.; Cho, S.-J.; Boo, J.-H. Investigation of copper and silver nanoparticles deposited on a nitrogen-doped diamond-like carbon (N-DLC) film electrode for bio-sensing. J. Korean Phys. Soc.; 2012; 60, pp. 912-915. [DOI: https://dx.doi.org/10.3938/jkps.60.912]
22. Choi, T.; Kim, S.H.; Lee, C.W.; Kim, H.G.; Cho, S.-K.; Kim, S.-H.; Kim, E.Y.; Park, J.; Kim, H.J. Synthesis of carbon nanotube–nickel nanocomposites using atomic layer deposition for high-performance non-enzymatic glucose sensing. Biosens. Bioelectron.; 2015; 63, pp. 325-330. [DOI: https://dx.doi.org/10.1016/j.bios.2014.07.059] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/25113051]
23. Daniel, M.C.; Astruc, D. Structure and dynamics of poly ethylene glycol coated Au nanoparticles. Chem. Rev.; 2004; 104, pp. 293-346. [DOI: https://dx.doi.org/10.1021/cr030698+] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/14719978]
24. Hutchings, G.J. Catalysis by gold. Catal. Today; 2005; 100, pp. 55-61. [DOI: https://dx.doi.org/10.1016/j.cattod.2004.12.016]
25. Hvolbæk, B.; Janssens TV, W.; Clausen, B.S.; Hanne, F.; Claus, H.C.; Jens, K.N. Catalytic activity of Au nanopart. Nano Today; 2007; 2, pp. 14-18. [DOI: https://dx.doi.org/10.1016/S1748-0132(07)70113-5]
26. Mena, M.L.; Yanez-Sedeno, P.; Pingarron, J.M. A comparison of different strategies for the construction of amperometric en-zyme biosensors using gold nanoparticle-modified electrodes. Anal. Biochem.; 2005; 336, pp. 20-27. [DOI: https://dx.doi.org/10.1016/j.ab.2004.07.038]
27. Hrapovic, S.; Liu, Y.L.; Male, K.B.; Luong, J.H.T. Electrochemical Biosensing Platforms Using Platinum Nanoparticles and Carbon Nanotubes. Anal. Chem.; 2004; 76, pp. 1083-1088. [DOI: https://dx.doi.org/10.1021/ac035143t]
28. Male, K.B.; Hrapovic, S.; Liu, Y.L.; Wang, D.; Luong, J.H.T. Electrochemical detection of carbohydrates using copper nanoparticles and carbon nanotubes. Anal. Chim. Acta; 2004; 516, pp. 35-41. [DOI: https://dx.doi.org/10.1016/j.aca.2004.03.075]
29. Zhu, H.; Ma, L.; Liu, N.; Wei, Q.; Wu, D.; Wang, Y.; Long, H.; Yu, Z. Improvement in anti-corrosion property of hydrogenated diamond-like carbon film by modifying CrC interlayer. Diam. Relat. Mater.; 2017; 72, pp. 99-107. [DOI: https://dx.doi.org/10.1016/j.diamond.2017.01.013]
30. Ibl, N. Some theoretical aspects of pulse electrolysis. Surf. Technol.; 1980; 10, pp. 81-104. [DOI: https://dx.doi.org/10.1016/0376-4583(80)90056-4]
31. Ferrari, A.; Kleinsorge, B.; Adamopoulos, G.; Robertson, J.; Milne, W.I.; Stolojan, V.; Brown, L.M.; Libassi, A.; Tanner, B.K. Determination of bonding in amorphous carbons by electron energy loss spectroscopy, Raman scattering and X-ray reflectivity. J. Non-Cryst. Solids; 2000; 266, pp. 765-768. [DOI: https://dx.doi.org/10.1016/S0022-3093(00)00035-1]
32. Yang, G.; Liu, E.; Khun, N.W.; Jiang, S.P. Direct electrochemical response of glucose at nickel-doped diamond like carbon thin film electrodes. J. Electroanal. Chem.; 2009; 627, pp. 51-57. [DOI: https://dx.doi.org/10.1016/j.jelechem.2008.12.019]
33. Kiang, C.-H.; Goddard Iii, W.A.; Beyers, R.; Goddard, W.A. Carbon nanotubes with single-layer walls. Carbon; 1995; 33, pp. 903-914. [DOI: https://dx.doi.org/10.1016/0008-6223(95)00019-A]
34. Grill, A. Electrical and optical properties of diamond-like carbon. Thin. Solid Film.; 1999; 355, pp. 189-193. [DOI: https://dx.doi.org/10.1016/S0040-6090(99)00516-7]
35. Li, G.; Huo, H.; Xu, C. Ni0.31Co0.69S2 nanoparticles uniformly anchored on a porous reduced graphene oxide framework for a high-performance non-enzymatic glucose sensor. J. Mater. Chem. A; 2015; 3, pp. 4922-4930. [DOI: https://dx.doi.org/10.1039/C4TA06553K]
36. Dai, W.; Li, M.; Gao, S.; Xu, S.; Wu, X.G.; Yang, B.H. Fabrication of Nickel/nanodiamond/boron-doped diamond electrode for non-enzymatic glucose biosensor. Electrochim. Acta; 2016; 187, pp. 413-421. [DOI: https://dx.doi.org/10.1016/j.electacta.2015.11.085]
37. Yuan, B.; Xu, C.; Deng, D.; Xing, Y.; Liu, L.; Pang, H.; Zhang, D. Graphene oxide/nickel oxide modified glassy carbon electrode for supercapacitor and non-enzymatic glucose sensor. Electrochim. Acta; 2013; 88, pp. 708-712. [DOI: https://dx.doi.org/10.1016/j.electacta.2012.10.102]
38. Li, M.; Bo, X.; Mu, Z.; Zhang, Y.; Guo, L. Chemical, Electrodeposition of nickel oxide and platinum nanoparticles on electrochemically re-duced graphene oxide film as a nonenzymatic glucose sensor. Sens. Actuators B Chem.; 2014; 192, pp. 261-268. [DOI: https://dx.doi.org/10.1016/j.snb.2013.10.140]
39. Sun, A.; Zheng, J.; Sheng, Q. A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in ionic liquids. Electrochim. Acta; 2012; 65, pp. 64-69. [DOI: https://dx.doi.org/10.1016/j.electacta.2012.01.007]
40. Qiao, N.; Zheng, J. Nonenzymatic glucose sensor based on glassy carbon electrode modified with a nanocomposite composed of nickel hydroxide and graphene. Electrochim. Acta; 2012; 177, pp. 103-109. [DOI: https://dx.doi.org/10.1007/s00604-011-0756-3]
41. Arvinte, A.; Sesay, A.-M.; Virtanen, V.J.T. Carbohydrates electrocatalytic oxidation using CNT–NiCo-oxide modified electrodes. Talanta; 2011; 84, pp. 180-186. [DOI: https://dx.doi.org/10.1016/j.talanta.2010.12.051]
42. Toghill, K.E.; Xiao, L.; Phillips, M.A.; Compton, R.G. The non-enzymatic determination of glucose using an electrolytically fabricated nickel microparticle modified boron-doped diamond electrode or nickel foil electrode. Sens. Actuators B Chem.; 2010; 147, pp. 642-652. [DOI: https://dx.doi.org/10.1016/j.snb.2010.03.091]
43. Amiripour, F.; Ghasemi, S.; Naser Azizi, S. A novel non-enzymatic glucose sensor based on gold-nickel bimetallic nanoparticles doped aluminosilicate framework prepared from agro-waste material. Appl. Surf. Sci.; 2021; 1, 537. [DOI: https://dx.doi.org/10.1016/j.apsusc.2020.147827]
44. Emir, G.; Dilgin, Y.; Ramanaviciene, A. Amperometric nonenzymatic glucose biosensor based on graphite rod electrode modified by Ni-nanoparticle/polypyrrole composite. Microchem. J.; 2021; 2, 161. [DOI: https://dx.doi.org/10.1016/j.microc.2020.105751]
45. Wei, H.; Xue, Q.; Li, A.; Wan, T.; Huang, Y.; Cui, D.; Pan, D.; Dong, B.; Wei, R.; Naik, N. et al. Dendritic core-shell copper-nickel alloy@metal oxide for efficient non-enzymatic glucose detection. Sens. Actuator B Chem.; 2021; 7, 337.
46. Kannan, P.; Maiyalagan, T.; Marsili, E.; Ghosh, S.; Niedziolka-Jönsson, J.; Jönsson-Niedziolka, M. Hierarchical 3-dimensional nickel–iron nanosheet arrays on carbon fiber paper as a novel electrode for non-enzymatic glucose sensing. Nanoscale; 2016; 8, pp. 843-855. [DOI: https://dx.doi.org/10.1039/C5NR06802A]
47. Zhang, Y.; Yang, Y.; Xiao, P.; Zhang, X.; Lu, L.; Li, L. Preparation of Ni nanoparticle-TiO2 nanotube composite by pulse electrodeposition. Mater. Lett.; 2009; 63, pp. 2429-2431. [DOI: https://dx.doi.org/10.1016/j.matlet.2009.08.019]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
In this paper, a Ni and diamond-like carbon (DLC)-modified TiO2 nanotube composite electrode was prepared as a glucose sensor using a combination of an anodizing process, electrodeposition, and magnetron sputtering. The composition and morphology of the electrodes were analyzed by a scanning electron microscope and energy dispersive X-ray detector, and the electrochemical glucose oxidation performance of the electrodes was evaluated by cyclic voltammetry and chronoamperometry. The results show that the Ni-coated DLC-modified TiO2 electrode has better electrocatalytic oxidation performance for glucose than pure TiO2 and electrodeposited Ni on a TiO2 electrode, which can be attributed to the synergistic effect between Ni and carbon. The glucose test results indicate a good linear correlation in a glucose concentration range of 0.99–22.97 mM, with a sensitivity of 1063.78 μA·mM−1·cm−2 and a detection limit of 0.53 μM. The results suggest that the obtained Ni-DLC/TiO2 electrode has great application potential in the field of non-enzymatic glucose sensors.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 School of Materials and Engineering, Central South University, Changsha 410083, China; The Third Xiangya Hospital, Central South University, Changsha 410013, China
2 School of Materials and Engineering, Central South University, Changsha 410083, China
3 School of Physics and Electronics, Central South University, Changsha 410083, China