Full text

Turn on search term navigation

© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Conventional triangular weirs have been originally developed to measure, divert, and control surface water. However, a special application of these weirs, such as for low flow measurements in full-scale monitoring of Green Infrastructure (GI), is not well investigated. Available head-discharge relationships for triangular sharp-crested weirs are only valid under a free-flow regime. Literature focusing on the V-notch weir usage for GI assessment suggests that it is necessary to calibrate the head-discharge relationship before its use. This study focuses on understanding the effects of site constraints on the measurement performance of a V-notch weir at low flow rates, and the validity of equations derived for similar applications that can be found in the literature. The variation of discharge coefficient in various flow regimes was investigated experimentally based on calibration runs covering flow rates between 0.054 l/s and 7 l/s. The results show that for 30° and 45° V-notch weirs, three flow regimes can be identified. It was observed that literature equations to calculate the discharge coefficient are valid for partially-contracted triangular weirs only at heads greater than vertex distance from the channel. However, for low flows that are expected to occur when estimating the full-scale performance of GI, the equations available from the literature for similar site conditions underestimated the flow rate between 85% and 17%. This emphasises the need for accurate calibration of a V-notch device under the site conditions to achieve the necessary level of accuracy in GI performance estimation. The procedure outlined in this work can be easily replicated to determine the optimal monitoring system configuration. Alternatively, if the site conditions would match those described in this study, the computed discharge using the proposed relations, in combination with the general V-notch weir equation, provides a significant improvement in the accuracy of measurements, expands the head applicability range of V-notch weirs, and enables better understanding of GI performance at the full scale.

Details

Title
Optimised Triangular Weir Design for Assessing the Full-Scale Performance of Green Infrastructure
Author
El Hattab, Mohamad H 1   VIAFID ORCID Logo  ; Mijic, Ana 1   VIAFID ORCID Logo  ; Vernon, Dejan 2 

 Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK 
 Thames Water Utilities Limited, Reading RG2 0RP, UK 
First page
773
Publication year
2019
Publication date
2019
Publisher
MDPI AG
e-ISSN
20734441
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2550500439
Copyright
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.