Full Text

Turn on search term navigation

© 2017 Katheria et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

The seventh edition of the American Academy of Pediatrics Neonatal Resuscitation Program recommends the use of a cardiac monitor in infants that need resuscitation. Previous trials have shown that EKG heart rate is available before pulse rate from a pulse oximeter. To date no trial has looked at how the availability of electrocardiogram (EKG) affects clinical interventions in the delivery room.

Objective

To determine whether the availability of an EKG heart rate value and tracing to the clinical team has an effect on physiologic measures and related interventions during the stabilization of preterm infants.

Design/Methods

Forty (40) premature infants enrolled in a neuro-monitoring study (The Neu-Prem Trial: NCT02605733) who had an EKG monitor available were randomized to have the heart rate information from the bedside EKG monitor either displayed or not displayed to the clinical team. Heart rate, oxygen saturation, FiO2 and mean airway pressure from a data acquisition system were recorded every 2 seconds. Results were averaged over 30 seconds and the differences analyzed using two-tailed t-test. Interventions analyzed included time to first change in FiO2, first positive pressure ventilation, first increase in airway pressure, and first intubation.

Results

There were no significant differences in time to clinical interventions between the blinded and unblinded group, despite the unblinded group having access to a visible heart rate at 66 +/- 20 compared to 114 +/- 39 seconds for the blinded group (p < .0001). Pulse rate from oximeter was lower than EKG heart rate during the first 2 minutes of life, but this was not significant.

Conclusion(s)

EKG provides an earlier, and more accurate heart rate than pulse rate from an oximeter during stabilization of preterm infants, allowing earlier intervention. All interventions were started earlier in the unblinded EKG group but these numbers were not significant in this small trial. Earlier EKG placement before pulse oximeter placement may affect other interventions, but this needs further study.

Details

Title
A pilot randomized controlled trial of EKG for neonatal resuscitation
Author
Katheria, Anup; Arnell, Kathy; Brown, Melissa; Hassen, Kasim; Maldonado, Mauricio; Wade, Rich; Finer, Neil
First page
e0187730
Section
Research Article
Publication year
2017
Publication date
Nov 2017
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1959663616
Copyright
© 2017 Katheria et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.