Content area
Full Text
(ProQuest: ... denotes non-US-ASCII text omitted.)
Academic Editor:R. Kacianauskas and Academic Editor:I. G. Raftoyiannis and Academic Editor:J. Wang
Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824, USA
Received 18 September 2013; Accepted 16 January 2014; 13 March 2014
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Concrete is widely used as a primary structural material in construction due to numerous advantages, such as strength, durability, ease of fabrication, and noncombustibility properties, it possesses over other construction materials. Concrete structural members when used in buildings have to satisfy appropriate fire safety requirements specified in building codes [1-4]. This is because fire represents one of the most severe environmental conditions to which structures may be subjected; therefore, provision of appropriate fire safety measures for structural members is an important aspect of building design.
Fire safety measures to structural members are measured in terms of fire resistance which is the duration during which a structural member exhibits resistance with respect to structural integrity, stability, and temperature transmission [5, 6]. Concrete generally provides the best fire resistance properties of any building material [7]. This excellent fire resistance is due to concrete's constituent materials (i.e., cement and aggregates) which, when chemically combined, form a material that is essentially inert and has low thermal conductivity, high heat capacity, and slower strength degradation with temperature. It is this slow rate of heat transfer and strength loss that enables concrete to act as an effective fire shield not only between adjacent spaces but also to protect itself from fire damage.
The behaviour of a concrete structural member exposed to fire is dependent, in part, on thermal, mechanical, and deformation properties of concrete of which the member is composed. Similar to other materials the thermophysical, mechanical, and deformation properties of concrete change substantially within the temperature range associated with building fires. These properties vary as a function of temperature and depend on the composition and characteristics of concrete. The strength of concrete has significant influence on its properties at both room and high temperatures. The properties of high strength concrete (HSC) vary differently with...