1. Introduction
Implant placement is followed by the osseointegration progress, after which a second surgery phase occurs [1,2,3,4,5,6]. During this process, soft and bone tissues are healing around the implant and transepitelial surface, respectively. Implant abutment connects the internal and external oral environments; therefore, soft tissue creates a hermetic barrier around the abutment to prevent bacteria crossing this area and affecting clinical implant success [3,4,5,7,8,9,10]. Keratinocytes and fibroblasts are the main cells in charge of soft tissue sealing around the dental implant abutment; they prevent apical migration of the junctional epithelium and bone resorption [4,5,11] and reduce bacteria adhesion to the implant-abutment junction [12,13].
When selecting an implant material, it is important to take its biocompatibility into account as well as its cellular behavior around these surfaces [4]. A computer-aided design/computer-aided manufacturing (CAD/CAM) system has promoted the implantology evolution. This technology, introduced in 1985, helps clinicians decrease production time and adapt materials and structures [14,15,16,17,18,19,20,21]. Many new-generation dentistry materials are milled with this system, among which are Y-TZP and PMMA.
Zirconium has favorable mechanical properties as well as high biological stability and biocompatibility, and its surface has low plaque retention. The principal disadvantage of this material is its opacity (less aesthetic than other ceramic materials), which is solved when stabilized with yttrium. Y-TZP represents a more aesthetic option with more translucence. This material is the most common type of zirconia used in dentistry today [5,22,23,24,25,26,27,28].
This material exhibits favorable mechanical properties, largely due to the particle size in the structure (0.2–0.5 µm), which helps maintain the stable tetragonal phase. It presents a high flexural strength (900–1200 MPa), fracture resistance (7–10 MPa m1/2), and elasticity modulus (210 GPa). It is increasingly considered the alternative to titanium for aesthetic dental implant abutments in final restorations [29].
PMMA is a synthetic polymer that provides strength, color stability, and ease of repair, which are some of the essential qualities required for provisional material [4]. Some manufacturers have converted this classical removable prosthesis material into a long-term crown or abutment temporary material milled with a CAD/CAM system. This option reduces some of the principal PMMA disadvantages, as it releases monomer into the medium during polymerization because CAD/CAM allows for a controlled polymerization under optimum pressure and temperature. Similarly to reticular infiltrate, polymethyl methacrylate CAD/CAM blocks have various specifications [16,19,29,30,31,32,33,34,35,36,37].
This method also minimizes clinical chairside time and enables better marginal fit and strength. Its favorable mechanical properties, i.e., high elastic modulus (2800 MPa) and flexural resistance (>80 MPa), makes PMMA one of the most used temporary materials [30,33].
Y-TZP and PMMA are widely used in daily clinical practice, with appropriate results in most patients. Figure 1 and Figure 2 show some examples. Even though both materials have been widely studied in the last few years (especially PMMA, which has been used in dentistry for a long time), only a few authors have pointed out their CAD/CAM manufacturing and application as a crown or trasepitelial abutment and their peripheral cell contact. Furthermore, the aim of the present review is to analyze human gingival fibroblasts’ response to contact with both these materials.
2. Materials and Methods
We conducted the present literature review according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and following the PICO format (P: population; I: intervention; C: comparison; O: outcome) in January 2022 (Table 1).
We conducted an additional electronic search in the PubMed and Scopus databases to identify both materials’ behavior (Y-TZP and PMMA) in the oral environment and in contact with peri-implant soft tissue. We used the following search strategy:
-. (“yttria-stabilized tetragonal zirconia polycrystal” OR “ytzp” OR “ytrium tetragonal zirconia polycrystal” OR “pmma” OR “polymethyl methacrylate”) AND (“dental implant” OR “dentistry”)
-. (“yttria-stabilized tetragonal zirconia polycrystal” OR “ytzp” OR “ytrium tetragonal zirconia polycrystal” OR “pmma” OR “polymethyl methacrylate”) AND “dentistry and restoration”
-. (“yttria-stabilized tetragonal zirconia polycrystal” OR “ytzp” OR “ytrium tetragonal zirconia polycrystal” OR “pmma” OR “polymethyl methacrylate”) AND (“dental implant” OR “dental prosthesis” OR “cad cam”)
We limited the search to English and Spanish publications, reviews, systematic reviews, meta-analyses, clinical trials, clinical studies, and comparative studies. We also filtered articles obtained for those that had been published in the last 5 years (from January 2017 to January 2022).
Once we filtered the publications, we applied the inclusion (Table 2) and exclusion criteria (Table 3).
Two experts conducted the paper selection, both of whom declared they did not have conflicts in this selection. Figure 3, represented as a “traffic lane” chart, presents the risk of bias for each article selected.
3. Results
The electronic search using PICO format in the PubMed/Medline database yielded a total of 26,057 articles. We identified 6003 more articles in the conventional electronic search on the same platform. After applying our filter (type of study and <5 years since literature search), we obtained 4461 articles in the first search and 643 in the second one.
Reviewers proceeded to screen all the studies using title and abstract; they then excluded duplicates and unavailable articles. We full-text analyzed 23 publications of interest, resulting in a total of 8 articles included in this paper.
Table 4 summarizes all selected studies.
4. Discussion
Gingiva is the epithelium in charge of creating a barrier (biological seal) between the abutment and the connective tissue. This barrier should adhere to the implant abutment surface, which has the function of creating stability between soft and hard tissues (protecting implant—abutment connection and peri-implant bone) and protecting against noxious bacteria; it also has an acceptable aesthetic quality. The protective barrier requires a nontoxic material that favors the attachment and growth of the surrounding tissues [29]. Y-TZP and PMMA have been widely studied, and the findings of different authors coincide in their biocompatibility and appropriate fibroblast response.
We analyzed yttria-stabilized tetragonal zirconia polycrystal and polymethyl methacrylate from a clinical perspective in two of the selected articles on which we based this research [38,39,40,41,42]. Bagegni A et al. presented a complete meta-analysis, examining various implant-fixed restorations (interim or definitive) and their effect on implant survival. On one hand, the authors concluded that metal-ceramic FCDs are more effective in implant survival than other materials [38] because they did not differentiate between groups of zirconium-derived materials. Moreover, the authors assumed that all material restoration should be fixed to a metal structure. On the other hand, they deduced that the survival of FCDs seems not to be affected by the choice of restorative material [38].
Díez-Quijano et al. compared PMMA to POM (polyoxymethylene) as a provisional implant-prosthetic material in a randomized clinical trial. Experts evaluated some clinical parameters (surface color, anatomic shape, marginal integrity, and screw-related complications) during the follow-up periods (1 week, 3 months, and 6 months). Better results were obtained in PMMA cases [42].
Classically, PMMA was manufactured as a direct or indirect polymerizable material. However, today, the CAD/CAM system has helped improve this material. PMMA CAD/CAM milling is especially useful in cases of implant-supported prosthesis and implant abutment. A number of authors agree about one of the most important advantages of this system: reduction of polymerization shrinkage and elimination of residual monomer released [4,39,40].
In some studies, researchers compared CAD/CAM PMMA specimens with various materials. All of them obtained excellent results in relation to the material cytotoxicity. They also discovered that HGFs have appropriate COL-1 production and surface attachment [29,40].
Other PMMA-surface parameters (such as roughness) were analyzed, producing similar results to those of gold standard materials [4,39,40]. These outcomes support the use of polymethyl methacrylate as an excellent interim restoration and implant-abutment material.
Y-TZP has been compared to other classical materials (such as lithium disilicate and titanium) as a dental-implant abutment. Its noteworthy physical and biological properties make this material an effective alternative to classical materials. Some of its properties are high biological stability, translucence (it does not need to be covered with feldespathic ceramics), an elastic modulus of 210 MPa, and excellent mechanical strength (800–1200 MPa) [5,29]. We carried out MTT assays with Y-TZP discs, obtaining appropriate results in in vitro studies with human gingival fibroblasts [29,43].
This material’s high flexibility and other physical alterations in the face of aging procedures have also been tested. This affirmation proves this material’s high resistance in an oral environment [41].
Researchers have proven that fibroblasts grown on Y-TZP shows great extension of the actin filaments and an elongated shape, which occurs because fibroblasts that grow on smoother surfaces (such as Y-TZP) are forced to stabilize themselves, developing a strong network of actin fibers and appearing more elongated and spread out. HGFs present a strong cytoskeleton when they grow on heterogeneous topography, such as rough surfaces [5,8,11].
Few papers have been published that analyze human gingival fibroblasts’ response to contact with Y-TZP or PMMA. Future long-term clinical or in vitro studies should be proposed to complement clinical and biological information collected in the present review.
5. Conclusions
Both materials have been demonstrated to be effective options for use as temporary or definitive abutment/prosthesis material. Many studies have shown that they promote a favorable fibroblast response, which translates into an appropriate soft-tissue seal, low bacteria adhesion, and long duration of the material in the oral cavity.
C.H.-G., M.R.-G., S.M.-S., M.-A.S.-F. and D.T.-L. conceived and designed the review. C.H.-G., M.R.-G., S.M.-S., M.-A.S.-F. and D.T.-L. wrote and supervised the paper. All authors have read and agreed to the published version of the manuscript.
This research received no external funding.
Not applicable.
Not applicable.
The data presented in this study are available on request from the corresponding author.
The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Figure 1. Clinical example of Y-TZP (Corcon® htML Dentsply Sirona, York, PA, USA) used in an implant for definitive rehabilitation: (a) Frontal clinical view of the definitive prosthesis placed over five implants, (b) View of the design software used in this clinical case (inLab CAD Dentsply Sirona, York, PA, USA).
Figure 2. Clinical example of PMMA (Telio CAD Ivoclar-Vivadent, Schaan, Liechtenstein) used in an implant for temporary rehabilitation: (a) Lateral clinical view of the definitive prosthesis placed over five implants, (b) View of the design software used in this clinical case (inLab CAD Dentsply Sirona, York, PA, USA).
Figure 3. Risk of bias graph, review of authors’ judgements about each risk of bias item presented as a percentage.
Overview of the search strategy following the PICO format.
PICO Question | What Are the Differences between Fibroblast Behavior on YTZP and PMMA? | |
---|---|---|
Search strategy | P |
edentulous OR crown OR edentulism OR fixed dental prosthesis OR implant-supported prosthesis OR implant-supported denture OR dental prosthesis, implant-supported OR dental abutment |
I |
yttria-stabilized tetragonal zirconia polycrystal OR ytzp OR y-tzp OR ytzps OR y-tzps AND cad cam | |
C |
polymethyl methacrylate OR pmma AND cad cam | |
O |
fibroblasts OR gingival fibroblast OR gingiva |
Search strategy and results of identification, screening for eligibility, and inclusion of publications considered for review.
Identification | Records identified through electronic database search according to PICO format (PubMed) |
Records identified through electronic database search according to keyword combination strategy (PubMed and Scopus) |
|
Screening | n = 4461 |
n = 643 |
Filter application |
n = 17 | n = 27 | Studies screened (title and abstract) | |
Eligibility | [Image omitted. Please see PDF.] |
||
Included | [Image omitted. Please see PDF.] |
Inclusion and exclusion criteria list.
Inclusion Criteria | Exclusion Criteria |
---|---|
Publications in English or Spanish | Studies on animals |
CAD/CAM Y-TZP or PMMA | Patients rehabilitated with removal prosthesis |
Fixed implant prosthesis | Teeth restorations |
Implant abutment | The material’s aesthetic characteristics |
The material’s physical and biological characteristics | Implant material |
Overview of included studies.
Author, |
Study Type | Material | Implants/Discs |
Aim | Main Conclusion |
---|---|---|---|---|---|
Bagegni A et al. |
Systematic review | Metal-ceramic | 8938 | Assess the influence of various restorative materials on implant survival supporting FCDs **. | Implant-supported FCD material selection seems not to affect prosthetic survival rates. |
Meta-analysis | Alloy |
||||
Pituru SM et al. |
Review | PMMA | NR | Synthetize main PMMA characteristics as interim implant-prosthetic restoration material. | PMMA is an interim prosthetic material with predictable prosthetic results. |
Shim JS et al. |
In vitro study | Poly(ethyl methacrylate) PMMA | 210 | Evaluate HGFs’ response to various interim prosthetic materials fabricated using three methods (direct, indirect, CAD/CAM). | PMMA manufactured by CAD/CAM system offers lower cytotoxicity to HGF and better cell attachment. |
Herráez-Galindo C et al. |
In vitro study | PMMA |
NR | Compare material surface and HGF behavior. | The two materials exhibited similar cellular reactions. |
Guilardi LF et al. |
In vitro study | Y-TZP | 30 | Characterize and compare the effect of various aging regimens on surface characteristics, structural stability, and mechanical performance. | None of the aging regimens impaired Y-TZP’s mechanical behavior. |
Díez-Quijano C et al. |
Randomized clinical trial | POM |
49 | Evaluate clinical performance of both CAD/CAM materials in implant-supported interim restorations. | PMMA performed better than POM. |
Rizo-Gorrita M et al. |
In vitro study | PMMA |
160 | Evaluate cytotoxic effect and COL-1 secretion of HGFs for materials studied. | Ceramic materials showed better cell responses than polymer materials. |
Pandoleon P et al. |
In vitro study | Y-TZP |
315 | Investigate biological effect of Y-TZP abutment compared to LS2 and Ti and HGFs’ viability and attachment properties. | Comparable biological results in Y-TZP and conventional abutment materials. |
* Implant-supported FCDs, ** FCDs (fixed completed dentures).
References
1. D’Addona, A.; Ghassemian, M.; Raaelli, L.; Manicone, P.F. Soft and hard tissue management in implant therapy—Part I: Surgical concepts. Int. J. Biomater.; 2012; 2012, 531202. [DOI: https://dx.doi.org/10.1155/2012/531202] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/22829828]
2. Fischer, N.G.; Wong, J.; Baruth, A.; Cerutis, D.R. Effect of Clinically Relevant CAD/CAM Zirconia Polishing on Gingival Fibroblast Proliferation and Focal Adhesions. Materials; 2017; 10, 1358. [DOI: https://dx.doi.org/10.3390/ma10121358]
3. Mehl, C.; Kern, M.; Schütte, A.M.; Kadem, L.F.; Selhuber-Unkel, C. Adhesion of living cells to abutment materials, dentin, and adhesive luting cement with different surface qualities. Dent. Mater.; 2016; 32, pp. 1524-1535. [DOI: https://dx.doi.org/10.1016/j.dental.2016.09.006]
4. Herráez-Galindo, C.; Rizo-Gorrita, M.; Luna-Oliva, I.; Serrera-Figallo, M.Á.; Castillo-Oyagüe, R.; Torres-Lagares, D. In vitro Comparative Study of Fibroblastic Behaviour o Polymethacrylate (PMMA) and Lithium Disilicate Polymer Surfaces. Polymers; 2019; 11, 744. [DOI: https://dx.doi.org/10.3390/polym11040744] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31027245]
5. Rizo-Gorrita, M.; Luna-Oliva, I.; Serrera-Figallo, M.Á.; Gutiérrez-Pérez, J.L.; Torres-Lagares, D. Comparison of Cytomorphometry and Early Cell Response of Human Gingival Fibroblast (HGFs) between Zirconium and New Zirconia-Reinforced Lithium Silicate Ceramics (ZLS). Int. J. Mol. Sci.; 2018; 19, 2718. [DOI: https://dx.doi.org/10.3390/ijms19092718] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30208663]
6. Pabst, A.M.; Walter, C.; Bell, A.; Weyhrauch, M.; Schmidtmann, I.; Scheller, H.; Lehmann, K.M. Influence of CAD/CAM zirconia for implant-abutment manufacturing on gingival fibroblasts and oral keratinocytes. Clin. Oral Investig.; 2016; 20, pp. 1101-1108. [DOI: https://dx.doi.org/10.1007/s00784-015-1598-x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/26395349]
7. Rutkunas, V.; Bukelskiene, V.; Sabaliauskas, V.; Balciunas, E.; Malinauskas, M.; Baltriukine, D. Assessment of human gingival fibroblast interaction with dental implant abutment materials. J. Mater. Sci. Mater. Med.; 2015; 26, 169. [DOI: https://dx.doi.org/10.1007/s10856-015-5481-8]
8. Tetè, S.; Zizzari, V.; Borelli, B.; De Colli, M.; Zara, S.; Sorrentino, R.; Scarano, A.; Gherlone, E.; Cataldi, A.; Zarone, F. Proliferation and adhesion capability of human gingival fibroblasts onto zirconia, lithium disilicate and feldspathic veneering ceramic in vitro. Dent. Mater. J.; 2014; 33, pp. 7-15. [DOI: https://dx.doi.org/10.4012/dmj.2013-185]
9. Grenade, C.; De Pauw-Gillet, M.; Gailly, P.; Vanheusden, A.; Mainjot, A. Biocompatibility of polymerinfiltrated-ceramic-network (PICN) materials with Human Gingival Fibroblasts (HGFs). Dent. Mater.; 2016; 32, pp. 1152-1164. [DOI: https://dx.doi.org/10.1016/j.dental.2016.06.020]
10. Furuhashi, A.; Ayukawa, Y.; Atsuta, I.; Okawachi, H.; Koyano, K. The difference of fibroblast behavior on titanium substrata with different surface characteristics. Odontology; 2012; 100, pp. 199-205. [DOI: https://dx.doi.org/10.1007/s10266-011-0029-y]
11. Rompen, E.; Domken, O.; Degidi, M.; Pontes, A.E.; Piattelli, A. The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: A literature review. Clin. Oral Implant. Res.; 2006; 17, pp. 55-67. [DOI: https://dx.doi.org/10.1111/j.1600-0501.2006.01367.x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/16968382]
12. Dal Piva, A.; Contreras, L.; Ribeiro, F.C.; Anami, L.C.; Camargo, S.; Jorge, A.; Bottino, M.A. Monolithic Ceramics: Effect of Finishing Techniques on Surface Properties, Bacterial Adhesion and Cell Viability. Oper. Dent.; 2018; 43, pp. 315-325. [DOI: https://dx.doi.org/10.2341/17-011-L] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29533718]
13. Pae, A.; Lee, H.; Kim, H.S.; Kwon, Y.D.; Woo, Y.H. Attachment and growth behaviour of human gingival fibroblasts on titanium and zirconia ceramic surfaces. Biomed. Mater.; 2009; 4, 25005. [DOI: https://dx.doi.org/10.1088/1748-6041/4/2/025005]
14. Awada, A.; Nathanson, D. Mechanical properties of resin-ceramic CAD/CAMrestorative materials. J. Prosthet. Dent.; 2015; 114, pp. 587-593. [DOI: https://dx.doi.org/10.1016/j.prosdent.2015.04.016] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/26141648]
15. Miyazaki, T.; Hotta, Y. CAD/CAM systems available for the fabrication of crown and bridge restorations. Aust. Dent. J.; 2011; 56, pp. 97-106. [DOI: https://dx.doi.org/10.1111/j.1834-7819.2010.01300.x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/21564120]
16. Li, R.; Chow, T.; Matinlinna, J. Ceramic dental biomaterials and CAD/CAM technology: State of the art. J. Prosthodontic Res.; 2014; 58, pp. 208-216. [DOI: https://dx.doi.org/10.1016/j.jpor.2014.07.003] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/25172234]
17. Horvath, S.D. Key Parameters of Hybrid Materials for CAD/CAM-Based Restorative Dentistry. Compend. Contin. Educ. Dent.; 2016; 37, pp. 638-643.
18. Pabst, A.; Walter, C.; Grassmann, L.; Weyhrauch, M.; Brüllmann, D.; Ziebart, T.; Scheller, H.; Lehmann, K.M. Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes. Clin. Oral Investig.; 2013; 18, pp. 1111-1118. [DOI: https://dx.doi.org/10.1007/s00784-013-1098-9]
19. Atay, A.; Gürdal, I.; Bozok Çetıntas, V.; Üşümez, A.; Cal, E. Effects of New Generation All-Ceramic and Provisional Materials on Fibroblast Cells. J. Prosthodont.; 2018; 28, pp. e383-e394. [DOI: https://dx.doi.org/10.1111/jopr.12915]
20. Coldea, A.; Swain, M.V.; Thiel, N. In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation. J. Mech. Behav. Biomed. Mater.; 2013; 26, pp. 34-42.
21. Proussaefs, P.; AlHelal, A. A technique for immediately restoring single dental implants with a CAD-CAM implant-supported crown milled from a poly(methyl methacrylate) block. J. Prosthet. Dent.; 2018; 119, pp. 339-344. [DOI: https://dx.doi.org/10.1016/j.prosdent.2017.03.025] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28689913]
22. Gautam, C.; Joyner, J.; Gautam, A.; Rao, J.; Vajtai, R. Zirconia based dental ceramics: Structure, mechanical properties, biocompatibility and applications. Dalton Trans.; 2016; 45, pp. 19194-19215. [DOI: https://dx.doi.org/10.1039/C6DT03484E] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/27892564]
23. El-Ghany, O.S.A.; Sherief, A.H. Zirconia based ceramics, some clinical and biological aspects: Review. Futur. Dent. J.; 2016; 2, pp. 55-64. [DOI: https://dx.doi.org/10.1016/j.fdj.2016.10.002]
24. Hallmann, L.; Ulmer, P.; Kern, M. Effect of microstructure on the mechanical properties of lithium disilicate glass-ceramics. J. Mech. Behav. Biomed. Mater.; 2018; 82, pp. 355-370. [DOI: https://dx.doi.org/10.1016/j.jmbbm.2018.02.032]
25. Chevalier, J. Critical effect of cubic phase on aging in 3mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis. Biomaterials; 2004; 25, pp. 5539-5545. [DOI: https://dx.doi.org/10.1016/j.biomaterials.2004.01.002]
26. Chevalier, J.; Gremillard, L.; Virkar, A.; Clarke, D.R. The Tetragonal-Monoclinic Transformation in Zirconia: Lessons Learned and Future Trends. J. Am. Ceram. Soc.; 2009; 92, pp. 1901-1920. [DOI: https://dx.doi.org/10.1111/j.1551-2916.2009.03278.x]
27. Kelly, J.R.; Denry, I. Stabilized zirconia as a structural ceramic: An overview. Dent. Mater.; 2008; 24, pp. 289-298. [DOI: https://dx.doi.org/10.1016/j.dental.2007.05.005]
28. Gupta, T.K.; Bechtold, J.H.; Kuznicki, R.C.; Cado, L.H.; Rossing, B.R. Stabilization of tetragonal phase in polycrystalline zirconia. J. Mater. Sci.; 1977; 12, 2421. [DOI: https://dx.doi.org/10.1007/BF00553928]
29. Rizo-Gorrita, M.; Herráez-Galindo, C.; Torres-Lagares, D.; Serrera-Figallo, M.Á.; Gutiérre-Pérez, J.L. Biocompatibility of Polymer and Ceramic CAD/CAM Materials with Human Gingival Fibroblasts (HGFs). Polymers; 2019; 11, 1446. [DOI: https://dx.doi.org/10.3390/polym11091446]
30. Yao, J.; Li, J.; Wang, Y.; Huang, H. Comparison of the flexural strength and marginal accuracy of traditional and CAD/CAM interim materials before and after thermal cycling. J. Prosthet. Dent.; 2014; 112, pp. 649-657. [DOI: https://dx.doi.org/10.1016/j.prosdent.2014.01.012]
31. Akin, H.; Tugut, F.; Polat, Z.A. In vitro comparison of the cytotoxicity and water sorption of two different denture base systems. J. Prosthodont.; 2015; 24, pp. 152-155. [DOI: https://dx.doi.org/10.1111/jopr.12162] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/24920440]
32. Salido, M.; Vilches, J.I.; Gutiérrez, J.L.; Vilches, J. Actin cytoskeletal organization in human osteoblasts grown on different dental titanium implant surfaces. Histol. Histopathol.; 2007; 22, pp. 1355-1364. [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/17701915]
33. Özçelik, T.B.; Yilmaz, B.; ¸Seker, E.; Shah, K. Marginal Adaptation of Provisional CAD/CAM Restorations Fabricated Using Various Simulated Digital Cement Space Settings. Int. J. Oral Maxillofac. Implant.; 2018; 33, pp. 1064-1069. [DOI: https://dx.doi.org/10.11607/jomi.6271] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30231093]
34. Srinivasan, M.; Gjengedal, H.; Cattani-Lorente, M.; Moussa, M.; Durual, S.; Schimmel, M.; Müller, F. CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent. Mater. J.; 2018; 37, pp. 526-533. [DOI: https://dx.doi.org/10.4012/dmj.2017-207] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29515054]
35. Abdullah, A.O.; Pollington, S.; Liu, Y. Comparison between direct chairside and digitally fabricated temporary crowns. Dent. Mater. J.; 2018; 37, pp. 957-963. [DOI: https://dx.doi.org/10.4012/dmj.2017-315]
36. Alp, G.; Murat, S.; Yilmaz, B. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers. J. Prosthodont.; 2019; 28, pp. e491-e495. [DOI: https://dx.doi.org/10.1111/jopr.12755]
37. Lo Giudice, G.; Cicciù, M.; Cervino, G.; Lizio, A.; Visco, A.M. Flowable resin andmarginal gap on tooth third medial cavity involving enamel and radicularcementum: A SEM evaluation of two restoration techniques. Indian J. Dent. Res.; 2012; 23, pp. 763-769.
38. Bagegni, A.; Abou-Ayash, S.; Rücker, G.; Algarny, A.; Att, W. The influence of prosthetic material on implant and prosthetic survival of implant-supported fixed complete dentures: A systematic review and meta-analysis. J. Prosthodont. Res.; 2019; 63, pp. 251-265. [DOI: https://dx.doi.org/10.1016/j.jpor.2019.02.001]
39. Pituru, S.M.; Greabu, M.; Totan, A.; Imre, M.; Pantea, M.; Spinu, T.; Tancu, A.M.C.; Popoviciu, N.O.; Stanescu, I.I.; Ionescu, E. A Review on the Biocompatibility of PMMA-Based Dental Materials for Interim Prosthetic Restorations with a Glimpse into their MModern Manufacturing Techniques. Materials; 2020; 13, 2894. [DOI: https://dx.doi.org/10.3390/ma13132894]
40. Shim, J.S.; Kim, H.C.; Park, S.I.; Yun, H.J.; Ryu, J.J. Comparison of Various Implant Provisional Resin Materials for Cytotoxicity and Attachment to Human Gingival Fibroblasts. Int. J. Oral Maxillofac. Implant.; 2019; 34, pp. 390-396. [DOI: https://dx.doi.org/10.11607/jomi.6707]
41. Guilardi, L.F.; Pereira, G.K.R.; Wandscher, V.F.; Rippe, M.P.; Valandro, L.F. Mechanical behavior of yttria-stabilized tetragonal zirconia polycrystal: Effects of different aging regimens. Braz. Oral Res.; 2017; 31, e94. [DOI: https://dx.doi.org/10.1590/1807-3107bor-2017.vol31.0094] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29236899]
42. Díez-Quijano, C.; Azevedo, L.; Antonaya-Martín, J.L.; Del Río-Highsmith, J.; Gómez-Polo, M. Evaluation of the clinical behavior of 2 different materials for implant-supported interim fixed partial prostheses: A randomized clinical trial. J. Prosthet. Dent.; 2020; 124, pp. 351-356. [DOI: https://dx.doi.org/10.1016/j.prosdent.2019.09.021] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31810613]
43. Pandoleon, P.; Bakopoulou, A.; Papadopoulou, L.; Koidis, P. Evaluation of the biological behaviour of various dental implant abutment materials on attachment and viability of human gingival fibroblasts. Dent. Mater.; 2019; 35, pp. 1053-1063. [DOI: https://dx.doi.org/10.1016/j.dental.2019.04.010] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31060818]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and polymethyl methacrylate (PMMA) are used very often in dentistry. Y-TZP is the most widely used zirconia dental ceramic, and PMMA has classically been used in removable prosthesis manufacturing. Both types of materials are commercialized in CAD/CAM system blocks and represent alternatives for long-lasting temporary (PMMA) or definitive (Y-TZP) implantological abutments. The aim of the present work is to reveal that human gingival fibroblasts (HGFs) have a favorable response when they are in contact with Y-TZP or PMMA as a dental implant abutment or implant-supported fixed prosthesis, and also to review their principal characteristics. We conducted an electronic search in the PubMed database. From an initial search of more than 32,000 articles, the application of filters reduced this number to 5104. After reading the abstracts and titles, we reduced the eligible articles to 23. Ultimately, we have included eight articles in this review.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer