Abstract

This paper aims at developing L-shaped hoop detail and evaluating structural and seismic performance of reinforced concrete columns when the developed hoop detail is applied. L-shaped hoop is introduced in this study to save construction time period by improving constructability. RC columns are fabricated having test parameters of concrete strength (24MPa and 35MPa) and hoop details (general hoop and L-shaped hoop). Axial and seismic loading tests are performed, and the test results of maximum column strength and load-strain curve of the column are similar regardless of hoop types. In addition, seismic test results show that hysteresis loops and energy dissipation capacity of the column specimens using two different hoop types (general hoop and L-shaped hoop) are similar.

Details

Title
Structural and seismic performance of RC columns with L-shaped hoop details
Author
Choi, Y H 1 ; Lee, Y K 1 ; Chun, Y J 1 ; Kim, H S 1 ; Shin, Y S 1 

 Architectural and Urban Systems Engineering Department, Ewha Womans University 03760 Seoul, South Korea 
Publication year
2019
Publication date
Oct 2019
Publisher
IOP Publishing
ISSN
17578981
e-ISSN
1757899X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2561342147
Copyright
© 2019. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.