Abstract
We introduce the application of a symmetric Talbot-Lau neutron grating interferometer which provides a significantly extended autocorrelation length range essential for quantitative dark-field contrast imaging. The highly efficient set-up overcomes the limitation of the conventional Talbot-Lau technique to a severely limited micrometer range as well as the limitation of the other advanced dark-field imaging techniques in the nanometer regime. The novel set-up enables efficient and continuous dark-field contrast imaging providing quantitative small-angle neutron scattering information for structures in a regime from some tens of nanometers to several tens of micrometers. The quantitative analysis enabled in and by such an extended range is demonstrated through application to reference sample systems of the diluted polystyrene particle in aqueous solutions. Here we additionally demonstrate and successfully discuss the correction for incoherent scattering. This correction results to be necessary to achieve meaningful quantitative structural results. Furthermore, we present the measurements, data modelling and analysis of the two distinct kinds of cohesive powders enabled by the novel approach, revealing the significant structural differences of their fractal nature.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 School of Mechanical Engineering, Pusan National University, Busan, Republic of Korea
2 Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Villigen, Switzerland; University of Geneva, Geneva, Switzerland
3 Neutron Science Center, Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
4 Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Villigen, Switzerland