© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

This paper presents thermodynamic and improvement potential analyses of a helium closed-cycle gas turbine power plant (Oberhausen II) and dominant plant components at four loads. DESIGN LOAD represents optimal operating conditions that cannot be obtained in exploitation but can be used as a guideline for further improvements. In real plant exploitation, the highest plant efficiency is obtained at NOMINAL LOAD (31.27%). Considering all observed components, the regenerator (helium-helium heat exchanger) is the most sensitive to the ambient temperature change. An exact comparison shows that the efficiency decrease of an open-cycle gas turbine power plant during load decrease is approximately two and a half or more times higher in comparison to a closed-cycle gas turbine power plant. Plant improvement potential related to all turbomachines leads to the conclusion that further improvement of the most efficient turbomachine (High Pressure Turbine—HPT) will increase whole plant efficiency more than improvement of any other turbomachine. An increase in the HPT isentropic efficiency of 1% will result in an average increase in whole plant efficiency of more than 0.35% at all loads during plant exploitation. In the final part of this research, it is investigated whether the additional heater involvement in the plant operation results in a satisfactory increase in power plant efficiency. It is concluded that in real exploitation conditions (by assuming a reasonable helium pressure drop of 5% in the additional heater), an additional heating process cannot be an improvement possibility for the Oberhausen II power plant.

Details

Title
Thermodynamic Analysis and Improvement Potential of Helium Closed Cycle Gas Turbine Power Plant at Four Loads
Author
Mrzljak, Vedran 1   VIAFID ORCID Logo  ; Poljak, Igor 2   VIAFID ORCID Logo  ; Maro Jelić 3 ; Prpić-Oršić, Jasna 1 

 Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia 
 Department of Maritime Sciences, University of Zadar, Mihovila Pavlinovića 1, 23000 Zadar, Croatia 
 Maritime Department, University of Dubrovnik, Ćira Carića 4, 20000 Dubrovnik, Croatia 
First page
5589
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
19961073
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2849010225
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.