Abstract
Objective: To describe various applications of homologous fibrin glue in maxillofacial surgery. The clinical outcomes of the treated cases are discussed.
Methods: During the period January 1993 to July 1995, 71 patients underwent maxillofacial procedures in which homologous fibrin glue was utilized. The material used in each case was Tisseel^sup TM^, which is composed of human fibrinogen and bovine thrombin. The material was used to provide close and secure re-approximation of soft tissue in 20 patients requiring coronal flaps. Bone or alloplast fixation was undertaken with fibrin sealant in 14 patients. In 13 cleft lip and palate patients, the material was used in the repair of residual fistulas or clefts. Twelve patients had sinus lift procedures where the material fixated the bone graft and repaired the torn mucoperiosteal lining. Finally, 12 patients with coagulopathies had fibrin glue placed following exodontia. All patients were followed for a minimum of 6 months postoperatively.
Results: Seventy patients treated with Tisseel^sup TM^ had successful outcomes as determined by preoperative criteria. A single oral antral fistula recurred 3 weeks after surgery. No adverse reaction to the material was noted in any of the patients.
Conclusions: Homologous fibrin glue has various applications in the field of maxillofacial surgery and can be used with safe and predictable results.
Surgeons have long sought a product that could act as both a tissue adhesive and a hemostatic agent. Unfortunately, the ideal characteristics of an adhesive differ from those of a hemostatic agent. Presently, fibrin glue demonstrates the best equilibrium between both properties.
Fibrin was first used by Bergell in 1909 to establish hemostasis. In 1915, Greyz used topical fibrin to provide for hemostasis while performing cerebral surgery. In 1940 Young and Medawar3 noted that fibrinogen could act as a tissue adhesive. Cronkite et al.4 in 1943, mixed bovine thrombin with plasma fibrinogen to produce the first biologic adhesive. One year later, Tidrick and Warren5 were using fibrin to fixate skin grafts. In 1972, Matras et al.6 enhanced the effectiveness of fibrin glue (FG) by increasing its fibrinogen concentration. Fearing possible viral transmission, the U.S. Food and Drug Administration banned the sale of homologous fibrin glue in 1978. Virally inactivated homologous fibrin glue has been available in Europe and Canada for numerous years. Presently, only autologous FG products are available in the United States, but phase-two clinical trials involving homologous fibrin glue are now underway.
Several homologous FG preparations exist. These include Tisseel^sup TM^ Beriplast^sup TM^, Biscol^sup TM^, and Hemacure^sup TM^. These products differ primarily in the concentration of their components. The various components of Tisseel are listed in Table 1.7
Preparation of the FG involves several steps and can be performed in approximately 10 minutes. The vials containing the Tisseel^sup TM^ and aprotinin solution are placed in the FibrinothermTM heating and mixing unit. The unit heats both components to 37degC. The aprotinin is then transfered using a supplied syringe into the Tisseel^sup TM^ vial. This forms component I. The Tisseel^sup TM^ vial contains a tiny mixing rod. When the vial is placed in the mixing part of the Fibrinotherm^sup TM^ unit, a uniform mixing and disolving of the product results. The clinician may choose the desired thrombin concentration, either 4 IU/mL or the faster setting 500 IU/mL. The calcium chloride is added to the heated thrombin via a second syringe. This forms component II. Components I and II are mixed together at delivery using the Duploject^sup TM^ syringe system. This supplied dual-syringe system allows the simultaneous application of both components, ensuring that they are quickly and thoroughly mixed. This system has numerous optional attachments, including spray heads and application catheters.
Concern exists over the possibility of viral transmission when using a pooled homologous blood source. Tisseel^sup TM^ is prepared from selected donors who undergo extensive screening. Virilogic testing and vapour heat treatment of all donor products is performed. To date, close to 2.5-million administrations of the product have occurred and not a single documented case of viral transmission has been noted. This article reports the results in 71 patients who received Tisseel^sup TM^ during maxillofacial procedures.
Material and Methods
During the period January 1993 to July 199S, homologous fibrin glue was used in 71 patients who underwent procedures in the maxillofacial region. The material used in all cases was Tisseel^sup TM^ (Immuno, Austria). The amount of material used and the postoperative course of each patient was noted. A breakdown of these data is noted in Table 2.
Sprayed FG was used to provide close and secure reapproximation of soft tissue in 20 patients requiring coronal flaps. In those patients undergoing esthetic procedures, FG was applied after addressing the frontalis, procerus, and corrugator supercil muscles, and during the final reapproximation of the overlying flap to its new position.
Bone grafts or alloplasts were fixated with FG in 14 patients. Ten patients had cancellous grafts stabilized with FG. The grafts were placed for either augmentation of alveolar ridges (Figs. 1 and 2), the reconstruction of mandibular discontinuity defects, or the stabilization of osteotomy sites (Fig. 3). Three alloplastic implants were stabilized with FG. In all cases, the alloplast used was Biocoral^sup TM^. Finally, in a single instance, an orbital-floor calvarial graft was fixated with FG (Fig. 4). The graft was used to reconstruct an orbital-floor defect in a patient with a zygomaticomaxillary fracture.
In 13 cleft lip and palate patients, persistent oronasal fistulae were repaired using local flaps and FG. All cases had failed earlier attempts at closure and presented with significant scarring of the palatal soft tissue. Fibrin glue was used in each instance to help with closure of the nasal lining. A combination of sutures and FG was used to provide oral closure.
Twelve patients underwent maxillary sinus lift bone grafting. Potential difficulties inherent with this technique include stabilizing the bone graft in the maxillary sinus. The second potential problem occurs when the thin mucoperiosteal-sinus lining is torn during the dissection. Fibrin glue was used to stabilize the cancellous bone in the desired position and to repair the thin sinus lining, thus ensuring that the graft was isolated from the lumen of the maxillary sinus (Fig. 5).
Finally, FG was used to achieve hemostasis in 12 patients who underwent dental extractions. The patients in whom FG was used had either a congenital factor deficiency (factor VIII or IX) or factor deficiency secondary to advanced liver disease. Following extraction of the involved teeth, the sockets were curreted and irrigated, and FG was applied to the sockets using the Duploject^sup TM^ syringe (Fig. 6). No further hemostatic measures were used.
Results
All patients were followed for a minimum of 6 months. The average amount of Tisseel^sup TM^ used per case was 5 mL (range, 1-12 mL). Table 2 lists the means and ranges of the amount of Tisseel^sup TM^ used for each procedure category.
Seventy patients treated with Tisseel^sup TM^ had successful outcomes. No adverse reaction to the material was noted in any patient. There were no postoperative hematoma or seroma formations in the coronal flap patients. Bone grafts and alloplasts fixated with FG remained radiographically in place during the healing or incorporation phase. No further bleeding in the coagulopathy patients who underwent extractions was noted. Twelve of the 13 oronasal fistulae remained successfully closed at a minimum of 6 months follow-up. A single fistula recurred 3 weeks after surgery.
Discussion
Fibrin glue mimicks the final stage of the coagulation cascade in which thrombin cleaves fibrinopeptides A and B from fibrinogen forming a fibrin monomer. Crosslinking of the fibrin monomer by the action of factor XIII in the presence of calcium results in a stable fibrin clot. Hemostasis is thus possible, even in the face of a coagulation defect.
Presently, both homologous and autologous forms of fibrin glue have found numerous applications in various surgical specialties. In the field of orthopaedic surgery, FG has been used for the repair of osteochondral talar fractures and radial head fractures.
Cardiovascular surgeons have used the product for numerous years to seal both aortic and coronary artery leaks during bypass surgery, and to seal implanted vascular grafts. General surgeons have controlled gastrointestinal, hepatic, splenic, and pancreatic bleeding using FG. Thoracic surgeons have used FG to seal esophagogastric anastomoses and to close pleuropulmonary and bronchopleural fistula.8 Postoperative chylothorax has also been successfully treated using FG.9
Neurosurgeons have controlled intracranial bleeding and repaired dural tears with fibrin glue10,11 Fibrin glue has also been successfully used to stop postoperative CSF leaks.12 In the field of orbital surgery, FG has been used to reapproximate conjunctiva, repair corneal perforations, and treat retinal detachments.13
Otolaryngologists have used FG to decrease or eliminate the need for nasal packing following functional endoscopic sinus surgery.14 A decreased hospital stay was also noted when FG was used during thyroidectomies.15 Compared to diathermy, an FG-treated group had decreased post-tonsillectomy pain, with no difference in primary or secondary bleeding noted between the two groups.l6 Fibrin glue has also been used to secure tympanic membrane grafts and in ossicular reconstruction.17
In the area of craniofacial surgery, Marchac and Renier18 mixed FG with a bone paste. The paste was mixed with the fibrin/aprotinin component alone in a 1:1 ratio. The thick paste was then molded into the desired shape, after which the thrombin component was added causing it to solidify. The final product could be further shaped and was easier to secure to the recipient site than cancellous bone alone. Marchac and Sandor19 demonstrated a statistically significant decrease in major hematoma development when FG was sprayed between the SMAS layer and the overlying skin flap in face-lift surgery. Blepharoplasty incisions have been closed with the aid of FG, necessitating fewer sutures. Grafts for the coverage of burns or difficult wounds have been successfully secured in place with FG alone or in combination with a minimal number of sutures.
Fibrin glue has numerous applications in oral and maxillofacial surgery. Tayapongsak et al.20 used FG to secure cancellous bone grafts to homologous mandibles during reconstruction. In the rabbit model, FG allowed for easier soft-tissue reapproximation following osteoplasties of the mandibular condyle.21 Several clinicians have noted that hydroxyapatite granules are much more easily handled and are less likely to become displaced when FG is used to secure them.22
Cavernous hemangiomas of the tongue and lip have been initially treated with intralesional injection of Tisseel^sup TM^. Halling and Merten23 claim that hemangiomas less than 15 mm in diameter will involute spontaneously after 1 or 2 intralesional injections of FG performed over a 4-week period. The often-difficult excision of ranulas has also been facilitated by the intraluminal injection of FG, resulting in easier dissection once the material has solidified.24
Fibrin glue has been used to provide hemostasis following dental extraction in patients with inhereted coagulation defects or advanced liver disease, or in those taking anticoagulants. Martinowitz et al.25 described the use of FG in anticoagulated patients requiring exodontia with INR values above 2.5. Conventional hemostatic agents such as collagen matrices (Gelfoam^sup TM^), oxidized cellulose matrices (Surgicel^sup TM^), and topical thrombin are usually ineffective in patients with low platelet counts or deficient coagulation factors. Expensive replacement therapy is usually required in the factor-deficient patient. Rakocz et al.26 showed very good success at providing postextraction hemostasis with Tisseel^sup TM^ in all but the most severe of hemophiliacs. Martinowitz and Schulman27 claim that the use of FG instead of factor concentrates in exodontia and minor surgery result in a ten-fold reduction in cost. Factor replacement may still be neccessary but in reduced amounts. An evaluation of this is currently underway.
Tisseel^sup TM^ is one of the several commercially available homologous fibrin glues. The cost per mL is approximately Cdn$100, including the fibrin glue and applicator. This compares favourably with the quoted costs of autologous fibrin glue (US$103/mL plus US$50 for thrombin plus US$50 for the applicator).28 Autologous and homologous fibrin glue products also differ in terms of the content and concentration of components.
The concentration of fibrinogen is usually considerably lower in the autologous FG products compared to homologous FG. Fibrinogen is important for the shear adhesive strength of the product. Saltz et al.29 demonstrated experimentally that by increasing fibrinogen levels from 20 to 70 mg/mL, the shear adhesive strength of fibrin glue is increased 19-fold.
The breaking strength of the clot is affected by fibrin crosslinking; therefore, factor XIII levels are also important. Native factor XIII, loosely bound to the fibrinogen, is present in concentrations of 10 U/mL and seems to be adequate for efficacy of the fibrin glue.30
The working time of the fibrin glue can be altered by varying the concentration of the thrombin. When 4 IU/mL of thrombin is used, the working time is 30 or more seconds before a fibrin clot will form. When 500 IU/mL of thrombin is used, the fibrin clot forms within 5 seconds. This is fairly constant for thrombin concentrations between 20 and 1000 IU/m.30
The addition of an antifibrinolytic to fibrin glue is controversial and is one reason the FDA has not yet approved its sale in the United States. The antifibrinolytic most commonly used in homologous fibrin glue is bovine aprotinin. Tranexamic acid and aminocaproic acid have also been used. The manufacturers of homologous glue claim that the absorption rate of the fibrin glue can be slowed by the addition of an antifibrinolytic. This is of particular benefit in areas of high-fibrinolytic activity, such as the oral cavity, but may not be important in other tissues, such as bone.31
Several reactions to the components of fibrin glue have been noted. Nonfatal anaphylactic reactions to aprotinin have been described. Wuthrich et al.32 also demonstrated an IgE-mediated anaphylactic reaction to aprotinin. Aprotinin is a polypeptide derived from bovine lung and has potential antigenicity. Berguer et al.33 described two cases, one fatal, in which profound hypotension developed after treating deep liver lacerations with nonaprotinin-containing fibrin glue.
Bovine thrombin also contains bovine factor V, which can be antigenic. The inhibitors of bovine factor V can crossreact with human factor V. This can result in a significant reduction in human factor V levels. Reexposure to FG will also increase the likelihood of developing inhibitors. Tissucol^sup TM^ (Immuno, France) has overcome this problem by using human thrombin in their homologous FG preparations.
This article describes several new applications for homologous fibrin glue. The volume of FG used for some of the procedures is higher than expected as a result of a learning-curve phenomenon and operator and assistant errors, particularly during the early part of this series.
Broad conclusions on any of the procedures performed in our series are not possible due to the limited sample size and the lack of controls. We believe, however, that the use of FG improved our outcomes or facilitated the procedure in several ways.
Placement of osseointegrated implants in the posterior edentulous maxilla often requires bone grafting of this area. The graft, usually cancellous bone harvested from the ilium, is placed below an intact mucoperiosteal sinus lining. An intact lining stabilizes and isolates the graft from the remainder of the sinus. Several clinicians recommend aborting the procedure if large tears in the thin mucoperiosteal lining occur. Fibrin glue allowed us to stabilize the graft easily and repair tears in the lining, thus ensuring its isolation from the maxillary sinus.
Persistant oronasal fistulae are often challenging to repair. A double-layered closure is preferred, as it decreases the incidence of fistula recurrence. The nasal layer, however, can be difficult to close, particularly in redo cleft lip and palate cases. Fibrin glue allowed easier closure of the nasal layer.
Patients with coagulopathies of mild-to-moderate severity were able to undergo simple exodontia without the use of factor replacement. Fibrin glue, in this situation, appeared to be more cost effective, decreased the total treatment time, and in all but the most severe of coagulopathies, eliminated the risks involved with factor replacement.
Patient comfort was improved by spraying FG under coronal flaps during reapproximation, thus eliminating the need for postoperative drains. It would seem that this technique does not increase the risk of hematoma or seroma development.
In nonloaded areas, FG alone provided sufficient support for bone grafts. This not only eased the stabilization of cancellous grafts in particular, but also eliminated the potential need of having to remove the fixation hardware at a later date. There is, however, no contraindication to using FG in the presence of fixation hardware. This is often necessary in loaded areas requiring bone grafting of defects. Most recently, we have begun using FG together with bioresorbable plates (Lactosorb^sup TM^, Walter Lorenz, Jacksonville, FL) for recontructing complex maxillofacial fractures. Fibrin glue has been used to stabilize nonloaded bone grafts, and the resorbable plates have been used to fixate fractures. In our opinion, this is an ideal combination as it represents a completely biodegradable system.
Fibrin glue has numerous applications in the field of maxillofacial surgery. It is a safe, cost-effective, and clinically proven method of providing hemostasis, securing or glueing hard and soft tissue, and sealing friable or difficult-to-reach tissues. It does not, however, replace good surgical technique.
Future applications of this product include using FG as a vehicle for the delivery of antibiotics and growth factors. Improved methods of producing autologous fibrin glue and recombinant products are also under development. Presently, homologous fibrin glue offers several advantages over its autologous counterpart. These include lower cost, ease of procurement, and better mechanical properties. The only disadvantage is the possibility of disease transmission. To date, however, there has not been a single documented case of disease transmission in well over 2.5 million administrations of the product.
References
1. Bergel S. Uber Wirkungen des Fibrins. Dtsch Med Wochenschr 1909; 35:633.
2. Grey EG. Fibrin as a hemostatic in cerebral surgery. Surg Gynecol Obstet 1915; 21:452.
3. Young JZ, Medawar PB. Fibrin suture of peripheral nerves. Lancet 1940; 275:126.
4. Cronkite EP, Lozner EL, Deaver J. Use of thrombin and fibrinogen in skin grafting. JAMA 1944;124:976.
5. Tidrick RT, Warren ED. Fibrin fixation of skin transplants. Surgery 1944; 15:90.
6. Matras H, Dinges HP, Manoli B, et al. Zur nahtlosen interfaszikularen nerventransplantation im tierexperiment. Wien Med Wochenschr 1972; 122:517.
7. Two-Component Fibrin Sealant (Human), Vapor Heated TisseelTM Kit VH. Product information insert. Immuno AG, Vienna, Austria. Issued February 1993.
8. Glover W, Chavis TV, Daniel TM, et al. Fibrin glue application through the flexible fiberoptic bronchoscope: A closure of bronchopulmonary fistulas. J Thorac Cardiovasc Surg 1987; 93:470.
9. Akaogi E, Mitsui K, Sohara Y. Treatment of postoperative chylothorax with intrapleural fibrin glue. Ann Thorac Surg 1989; 48:116.
10. Haase J. Use of Tisseel in neurosurgery. J Neurosurg 1984; 61:801.
11. Shaffrey CI, Spotnitz WD, Shaffrey ME, Jane JA. Neurosurgical applications of fibrin glue: augmentation of dural closure in 134 patients. Neurosurgery 1990; 26:207.
12. Nissen AJ, Johnson AJ, Perkins RC, Welsh JE. Fibrin glue in otology and neurotology. Am J Otol 1993; 14:147. 13. Bartley GB, McCaffrey TV. Cryoprecipitated fibrinogen (fibrin glue) in orbital surgery (letter). Am J Ophthalmol 1990; 109:227.
14. Gleich LL, Rebeiz EE, Pankratov MM, Shapshay SM. Autologous fibrin tissue adhesive in endoscopic sinus surgery. Otolaryngol Head Neck Surg 1995;112:238.
15. Matthews TW, Briant TDR. The use of fibrin tissue glue in thyroid surgery: resource utilization implications. J Otolaryngol 1991; 20:276.
16. Moralee SJ, Carney AS, Cash MP, Murray JAM. The effect of fibrin sealant haemostasis on post-operative pain in tonsillectomy. Clin Otolaryngol 1994; 19:526.
17. Park MS. Autologous fibrin glue for tympanoplasty: Am J Otol 1994; 15:687.
18. Marchac D, Renier D. Fibrin glue in craniofacial surgery. J Craniofac Surg 1990; 1:32-34.
19. Marchac D, Sandor G. Face lifts and sprayed fibrin glue: an outcome analysis of 200 patients. Br J Plast Surg 1994; 47: 306-309.
20. Tayapongsak P, O'Brien DA, Monteiro CB, Arceo-Diaz LY. Autologous fibrin adhesive in mandibular reconstruction with particulate cancellous bone and marrow. J Oral Maxillofac Surg 1994; 52:161.
21. Kurita K, Westesson PL, Erikssonn L, Sternby NH. Osteoplasty of the mandibular condyle with preservation of the articular soft tissue cover: comparison of fibrin sealant and sutures for fixation of the articular soft tissue cover in rabbits. Oral Surg Oral Med Oral Pathol 1990; 69:661.
22. Hotz G. Alveolar ridge augmentation with hydroxylapatite using fibrin sealant for fixation. Part II: Clinical application. Int J Oral Maxillofac Surg 1991; 20:208.
23. Halling F, Merten HA. Use of fibrin sealant in the treatment of maxillofacial hemangiomas. In: Schlag G, Bosch P, Matras H, eds. Fibrin sealing in surgical and nonsurgical fields: orthopedic surgery, maxillofacial surgery. Berlin: Springer-Verlag, 1994:158-164.
24. Takimoto T, Ishikawa S, Nishimura T, et al. Fibrin glue in the surgical treatment of ranulas. Clin Otolaryngol 1989; 14:429.
25. Martinowitz U, Mazar AL, Taicher S, et al. Dental extractions for patients on oral anticoagulation therapy. Oral Surg Oral Med Oral Pathol 1990; 70:274.
26. Rakocz M, Mazar A, Varon D, et al. Dental extractions in patients with bleeding disorders. The use of fibrin glue. Oral Surg Oral Med Oral Pathol 1993; 75:280-282.
27. Martinowitz U, Schulman S. Fibrin sealant in surgery of patients with a hemorrhagic diathesis. Thromb Haemost 1995; 74:486.
28. Tawe RL, Sydorak GR, DuVall TB. Autologous fibrin glue: the last step inoperative hemostasis. Am J Surg 1994; 168: 120.
29. Saltz R, Sierra D, Feldman D, et al. Experimental and clinical applications of fibrin glue. Plast Reconstr Surg 1991; 88: 1005.
30. Byrne DJ, Hardy J, Wood RA, et al. Effect of fibrin glues on the mechanical properties of healing wounds. Br J Surg 1991; 78:841.
31. Matras H. Fibrin seal: the state of the art. J Oral Maxillofac Surg 1985; 43:605-611.
32. Wuthrich B, Schmid P, Schmid ER, Tornic M. IgE-mediated anaphylactic reaction to aprotinin during anaesthesia. Lancet 1992; 340:173.
33. Berguer R, Staerkel RL, Moore EE, et al. Warning: Fatal reaction to the use of fibrin glue in deep hepatic wounds. Case reports. J Trauma 1991; 31:408.
Received 4/28/97. Received revised 9/25/97. Accepted for publication 10/03/97.
Benamin R. Davis: Department of Oral and Maxillofacial Surgery, Queen Elizabeth Health Sciences Centre, Halifax, Nova Scotia; George K.B. Sandor: Acting Head, Division of Oral and Maxillofacial Surgery, The Toronto Hospital, The Hospital For Sick Children, The Bloorview MacMillan Centre, Toronto, Ontario.
Address reprint requests to: Dr. George K.B. Sandor, Department of Dentistry, The Hospital for Sick Children, 555 University Avenue, Toronto, ON MSG 1X8.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Decker Periodicals, Inc. Apr 1998